Restore the Airbus Network File Management Service (NFMS) Data
TASK 46-26-32-280-802-A
Restore the Airbus Network File Management Service (NFMS) Data
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 46-26-32-861-069-A ** ON A/C NOT FOR ALL
Subtask 46-26-32-280-055-A ** ON A/C NOT FOR ALL
Subtask 46-26-32-860-085-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.02 06:26:08 UTC
Restore the Airbus Network File Management Service (NFMS) Data
ZONE: 128
1. Reason for the JobSelf explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| 072-3175-001 | 1 | FOMAX LMF |
| 072-3175-003 | 1 | FOMAX LMF |
| 072-3175-004 | 1 | FOMAX LMF |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 128 | REAR AVIONIC COMPARTMENT |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-41-00-861-002-A | Energize the Aircraft Electrical Circuits from the External Power |
| TASK 24-41-00-861-002-A-01 | Energize the Aircraft Electrical Circuits from the APU |
| TASK 24-41-00-861-002-A-02 | Energize the Aircraft Electrical Circuits from Engine 1(2) |
| TASK 24-41-00-862-002-A | De-energize the Aircraft Electrical Circuits Supplied from the External Power |
| TASK 24-41-00-862-002-A-01 | De-energize the Aircraft Electrical Circuits Supplied from the APU |
| TASK 24-41-00-862-002-A-02 | De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2) |
| TASK 46-26-32-280-801-A-01 | Check of the Flight Operations and MAintenance eXchanger (FOMAX) Configuration with the Local Maintenance Function (LMF) |
| TASK 46-26-32-860-801-A | Connection of the Maintenance Electronic Device (with the Local Maintenance Function (LMF)) to the Flight Operations and MAintenance eXchanger (FOMAX) |
| TASK 46-26-32-860-806-A | Disconnection of the Maintenance Electronic Device (with the Local Maintenance Function (LMF)) from the Flight Operations and MAintenance eXchanger (FOMAX) |
Subtask 46-26-32-861-069-A ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
(1) Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002).
Subtask 46-26-32-865-072-A ** ON A/C NOT FOR ALL (1) Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002).
B. Make sure that this(these) circuit breaker(s) is(are) closed:
Subtask 46-26-32-860-084-A ** ON A/C NOT FOR ALL | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 121VU | FOMAX | 67TA | J01 |
| ** ON A/C NOT FOR ALL | |||
| 121VU | FOMAX | 67TA | R12 |
C. Connect the maintenance electronic device with the Local Maintenance Function (LMF) in operation to the FOMAX (Ref. AMM TASK 46-26-32-860-801).
4. ProcedureSubtask 46-26-32-280-055-A ** ON A/C NOT FOR ALL
A. Procedure
Subtask 46-26-32-280-055-B ** ON A/C NOT FOR ALL | ACTION | RESULT |
|---|---|
| 1.Make sure that you started the 072-3175-001 FOMAX LMF or the 072-3175-003 FOMAX LMF or the 072-3175-004 FOMAX LMF on the maintenance electronic device that is connected to the FOMAX. | |
| 2.Make sure that the Part Number (P/N) of the software that you will use to restore the data is the same as the P/N of the software that you use when you did the back-up: (Ref. AMM TASK 46-26-32-280-801). | |
3.On the LMF main page:
| On the LMF:
|
| 4.On the LMF home page, make sure that the LED adjacent to the "FOMAX Internal" button is green. | |
5.On the LMF, on the "FOMAX Internal" page:
| On the LMF:
|
6.On the "AB NFMS" page:
| |
A. Procedure
Subtask 46-26-32-280-055-CS ** ON A/C NOT FOR ALL | ACTION | RESULT |
|---|---|
| 1.Make sure that you started the 072-3175-003 FOMAX LMF or the 072-3175-004 FOMAX LMF on the maintenance electronic device that is connected to the FOMAX. | |
| 2.Make sure that the Part Number (P/N) of the software that you will use to restore the data is the same as the P/N of the software that you use when you did the back-up: (Ref. AMM TASK 46-26-32-280-801). | |
3.On the LMF main page:
| On the LMF:
|
| 4.On the LMF home page, make sure that the LED adjacent to the "FOMAX Internal" button is green. | |
5.On the LMF, on the "FOMAX Internal" page:
| On the LMF:
|
6.On the "AB NFMS" page:
| |
A. Procedure
5. Close-up| ACTION | RESULT |
|---|---|
| 1.Make sure that you started the 072-3175-004 FOMAX LMF on the maintenance electronic device that is connected to the FOMAX. | |
| 2.Make sure that the Part Number (P/N) of the software that you will use to restore the data is the same as the P/N of the software that you use when you did the back-up: (Ref. AMM D/O 46-26-32-28). | |
3.On the LMF main page:
| On the LMF:
|
| 4.On the LMF home page, make sure that the LED adjacent to the "FOMAX Internal" button is green. | |
5.On the LMF, on the "FOMAX Internal" page:
| On the LMF:
|
6.On the "AB NFMS" page:
| |
Subtask 46-26-32-860-085-A ** ON A/C NOT FOR ALL
A. Disconnect the maintenance electronic device with the LMF in operation from the FOMAX (Ref. AMM TASK 46-26-32-860-806).
Subtask 46-26-32-860-096-A ** ON A/C NOT FOR ALL B. Put the aircraft back to the serviceable condition.
(1) Make sure that the work area is clean and clear of tools and other items.
Subtask 46-26-32-862-069-A ** ON A/C NOT FOR ALL (1) Make sure that the work area is clean and clear of tools and other items.