Check of the Flight Operations and MAintenance eXchanger (FOMAX) Configuration with the Portable Data Loader (PDL)
TASK 46-26-32-280-801-A
Check of the Flight Operations and MAintenance eXchanger (FOMAX) Configuration with the Portable Data Loader (PDL)
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 46-26-32-861-060-A ** ON A/C NOT FOR ALL Subtask 46-26-32-010-057-A ** ON A/C NOT FOR ALL
Subtask 46-26-32-280-053-A ** ON A/C NOT FOR ALL
Subtask 46-26-32-410-059-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.02 06:26:08 UTC
Check of the Flight Operations and MAintenance eXchanger (FOMAX) Configuration with the Portable Data Loader (PDL)
ZONE: 128
1. Reason for the JobSelf explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE |
| ALT45200001 | 1 | PORTABLE DATA LOADER |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 128 | REAR AVIONIC COMPARTMENT |
| 824 |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-41-00-861-002-A | Energize the Aircraft Electrical Circuits from the External Power |
| TASK 24-41-00-861-002-A-01 | Energize the Aircraft Electrical Circuits from the APU |
| TASK 24-41-00-861-002-A-02 | Energize the Aircraft Electrical Circuits from Engine 1(2) |
| TASK 24-41-00-862-002-A | De-energize the Aircraft Electrical Circuits Supplied from the External Power |
| TASK 24-41-00-862-002-A-01 | De-energize the Aircraft Electrical Circuits Supplied from the APU |
| TASK 24-41-00-862-002-A-02 | De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2) |
Subtask 46-26-32-861-060-A ** ON A/C NOT FOR ALL Subtask 46-26-32-010-057-A ** ON A/C NOT FOR ALL
B. Get access to the avionics compartment.
(1) Put an ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position at access door 824 in zone 128.
(2) Open access door 824.
Subtask 46-26-32-480-051-A ** ON A/C NOT FOR ALL (1) Put an ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position at access door 824 in zone 128.
(2) Open access door 824.
C. Installation of the ALT45200001 PORTABLE DATA LOADER in the Avionics Compartment
(1) On the PDL, make sure that the ON/OFF switch is set to OFF.
(2) Remove the blanking cap from the FOMAX 615A data loader connector (1) (180VC).
(3) Connect the PDL cable to the FOMAX 615A data loader connector (1) (180VC).
Subtask 46-26-32-865-063-A ** ON A/C NOT FOR ALL (1) On the PDL, make sure that the ON/OFF switch is set to OFF.
(2) Remove the blanking cap from the FOMAX 615A data loader connector (1) (180VC).
(3) Connect the PDL cable to the FOMAX 615A data loader connector (1) (180VC).
D. Make sure that this(these) circuit breaker(s) is(are) closed:
Subtask 46-26-32-860-063-A ** ON A/C NOT FOR ALL 4. Procedure| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 121VU | FOMAX | 67TA | J01 |
| 121VU | PDL/PWR/SPLY | 14TD | K19 |
Subtask 46-26-32-280-053-A ** ON A/C NOT FOR ALL
A. Check of the FOMAX Configuration with the PDL
Subtask 46-26-32-860-064-A ** ON A/C NOT FOR ALL Subtask 46-26-32-080-051-A ** ON A/C NOT FOR ALL | ACTION | RESULT |
|---|---|
| On the PDL: 1.Do the initialization procedure. | On the PDL:
|
C. Removal of the PDL
(1) In the avionics compartment:
(a) Disconnect the cable from the ALT45200001 PORTABLE DATA LOADER and from the FOMAX 615A data loader connector (1) (180VC).
(b) Put the blanking cap on the FOMAX 615A data loader connector (1) (180VC).
5. Close-up(1) In the avionics compartment:
(a) Disconnect the cable from the ALT45200001 PORTABLE DATA LOADER and from the FOMAX 615A data loader connector (1) (180VC).
(b) Put the blanking cap on the FOMAX 615A data loader connector (1) (180VC).
Subtask 46-26-32-410-059-A ** ON A/C NOT FOR ALL
A. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the access door 824.
(3) Remove the access platform(s).
Subtask 46-26-32-862-060-A ** ON A/C NOT FOR ALL (1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the access door 824.
(3) Remove the access platform(s).
FOMAX Maintenance Plug 180VC on 80VU