Removal of the Air Traffic Service Unit (ATSU)
TASK 46-21-34-000-001-A
Removal of the Air Traffic Service Unit (ATSU)
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 46-21-34-810-050-A
Subtask 46-21-34-020-050-A
[Rev.10 from 2021]
2026.04.02 06:26:05 UTC
Removal of the Air Traffic Service Unit (ATSU)
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE |
| No specific | AR | CAP - BLANKING |
| No specific | AR | SAFETY CLIP - CIRCUIT BREAKER |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 127 | REAR AVIONIC COMPARTMENT |
| 824 |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 31-32-00-860-013-A | Procedure to Get Access to the SYSTEM REPORT/TEST/INFO SYS Page |
Subtask 46-21-34-810-050-A
A. Trouble Shooting Data
If available, you can print the Trouble Shooting Data (TSD) as follows:
Subtask 46-21-34-865-050-A If available, you can print the Trouble Shooting Data (TSD) as follows:
- get access to the SYSTEM/REPORT/INFO SYS page (Ref. AMM TASK 31-32-00-860-013).
- on this page, push the line key adjacent to the ATIMS indication.
- on the ATIMS page, push the line key adjacent to the TROUBLE SHOOTING DATA indication to get the TROUBLE SHOOTING DATA page.
- print the TROUBLE SHOOTING DATA (TSD) page(s).
B. Open, safety and tag this(these) circuit breaker(s):
Subtask 46-21-34-010-050-A | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 121VU | ATSU 1 | 3TX1 | L16 |
| 121VU | ATSU 1/SWTG | 5TX1 | L15 |
| ** ON A/C NOT FOR ALL | |||
| 121VU | ATSU 1 | 3TX1 | K43 |
| 121VU | ATSU 1/SWTG | 5TX1 | K42 |
C. Get access to the avionics compartment.
(1) Put an ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position at the access door 824 in zone 128.
(2) Open the access door 824.
4. Procedure(1) Put an ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position at the access door 824 in zone 128.
(2) Open the access door 824.
Subtask 46-21-34-020-050-A
A. Removal of the ATSU
(1) Loosen the nuts (4).
(2) Lower the nuts (4).
(3) Pull the ATSU (1) on its rack (3) to disconnect the electrical connectors (2).
(4) Remove the ATSU (1) from its rack (3).
(5) Put CAP - BLANKING on the disconnected electrical connectors (2).
(1) Loosen the nuts (4).
(2) Lower the nuts (4).
(3) Pull the ATSU (1) on its rack (3) to disconnect the electrical connectors (2).
(4) Remove the ATSU (1) from its rack (3).
(5) Put CAP - BLANKING on the disconnected electrical connectors (2).