Removal of the Datalink Control and Display Unit (DCDU)
TASK 46-21-21-000-001-A
Removal of the Datalink Control and Display Unit (DCDU)
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 46-21-21-861-050-A ** ON A/C NOT FOR ALL Subtask 46-21-21-865-050-A ** ON A/C NOT FOR ALL
Subtask 46-21-21-020-050-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.02 06:26:05 UTC
Removal of the Datalink Control and Display Unit (DCDU)
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | SAFETY CLIP - CIRCUIT BREAKER |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 211 | COCKPIT |
| 212 | COCKPIT |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-42-00-861-001-A | Energize the Ground Service Network from the External Power |
Subtask 46-21-21-861-050-A ** ON A/C NOT FOR ALL Subtask 46-21-21-865-050-A ** ON A/C NOT FOR ALL
B. Open, safety and tag this(these) circuit breaker(s):
4. Procedure| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 122VU | LIGHTING/INSTL LT/GLARE/SHLD | 5LF | Y05 |
| ** ON A/C NOT FOR ALL | |||
| FOR FIN: 2TX1 (DCDU1) | |||
| 121VU | DCDU 1 | 6TX1 | L17 |
| ** ON A/C NOT FOR ALL | |||
| 121VU | DCDU 1 | 6TX1 | K44 |
| ** ON A/C NOT FOR ALL | |||
| FOR FIN: 2TX2 (DCDU2) | |||
| 121VU | DCDU 2 | 6TX2 | L18 |
| ** ON A/C NOT FOR ALL | |||
| 121VU | DCDU 2 | 6TX2 | K45 |
Subtask 46-21-21-020-050-A ** ON A/C NOT FOR ALL
A. Removal of the DCDU
(1) Loosen the four screws (1) and washers (2).
(2) Pull the DCDU (3) from its housing.
(3) Disconnect the electrical connector (4).
(4) Remove the DCDU (3).
(5) Put a blanking cap on the disconnected electrical connector (4).
(1) Loosen the four screws (1) and washers (2).
(2) Pull the DCDU (3) from its housing.
(3) Disconnect the electrical connector (4).
(4) Remove the DCDU (3).
(5) Put a blanking cap on the disconnected electrical connector (4).
Datalink Control and Display Unit (DCDU)