W DOC AIRBUS | AMM A320F

Downloading of ATSU ISM internal memory


TASK 46-21-00-860-808-B
Downloading of ATSU ISM internal memory


CAUTION: DURING THE DOWNLOADING, MAKE SURE THAT MAINTENANCE PERSONNEL:
  • DO NOT CHANGE THE SOURCE OF THE AIRCRAFT POWER SUPPLY (GROUND POWER UNIT, APU, ETC.)
  • DO NOT TOUCH OR MOVE THE PORTABLE DATA LOADER (PDL).
IF YOU DO NOT OBEY THESE TWO PRECAUTIONS, FAILURE OF THE DOWNLOADING CAN OCCUR. IT CAN THEN BE NECESSARY TO DO THE FULL DOWNLOADING PROCEDURE AGAIN.
NOTE: ATSU RECORDS INFORMATION RELATED TO ITS FUNCTIONNING. THESE INFORMATION NAMED ISM (IN SERVICE MONITORING) TRACES ARE RECORDED IN INTERNAL DEDICATED ATSU MEMORIES. THESE INFORMATION ARE USED BY AIRBUS TO INVESTIGATE IN-SERVICE INCIDENTS AND ISSUES. PURPOSE OF THIS TASK IS TO RECOVER THIS MEMORIES CONTAIN.
NOTE: THE ISM MEMORIES IS RECORDED BY ATSU IN SIX FILES NAMED: ISM_FLASH_SYNC, ISM_FLASH_ASYNC1, ISM_FLASH2_ASYNC, ISM_FLASH_ASYNC3, ISM_FLASH4_ASYNC AND ISM_FLASH5_ASYNC.
NOTE: TO RETRIEVE A SPECIFIC ISM FILE A FILE NAMED " 0200_1.lnr " IS NEEDED. THIS FILE IS DIFFERENT FOR EACH ISM FILE TO RETRIEVE BUT HAS ALWAYS THE SAME NAME. THESE FILES SHOULD BE STORED IN CORRESPONDING REPOSITORY BEFORE ISM DOWNLOAD TASK STARTING: ISM_FLASH_SYNC, ISM_FLASH_ASYNC1, ISM_FLASH2_ASYNC, ISM_FLASH_ASYNC3, ISM_FLASH4_ASYNC, ISM_FLASH5_ASYNC. TO OBTAIN THESE FILES, PLEASE CONTACT THE AIRBUS CUSTOMER SERVICES DEPARTMENT.
NOTE: WHEN THE TASK IS COMPLETED RECOVERED ISM FILES SHOULD BE SENT TO AIRBUS.
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
1
ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE
ALT45200001
1
PORTABLE DATA LOADER
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
824
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 24-41-00-861-002-A
Energize the Aircraft Electrical Circuits from the External Power
TASK 24-41-00-861-002-A-01
Energize the Aircraft Electrical Circuits from the APU
TASK 24-41-00-861-002-A-02
Energize the Aircraft Electrical Circuits from Engine 1(2)
TASK 24-41-00-862-002-A
De-energize the Aircraft Electrical Circuits Supplied from the External Power
TASK 24-41-00-862-002-A-01
De-energize the Aircraft Electrical Circuits Supplied from the APU
TASK 24-41-00-862-002-A-02
De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2)
3. Job Set-up
Subtask 46-21-00-861-113-A ** ON A/C NOT FOR ALL
A. Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002).
Subtask 46-21-00-865-107-A ** ON A/C NOT FOR ALL
B. Make sure that this(these) circuit breaker(s) is(are) closed:
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
49VUAUTO FLT/MCDU/111CA1B01
** ON A/C NOT FOR ALL
49VUL/G/LGCIU/SYS1/NORM1GAC09
49VUFWS/FWC1/SPLY3WWF01
49VUCOM/RMP/12RG1G10
** ON A/C NOT FOR ALL
49VUAUTO FLT/MCDU/111CA1H07
** ON A/C NOT FOR ALL
121VUCFDS/CFDIU/SPLY2TWJ18
121VUPDL/PWR/SPLY14TDK19
121VUATSU 13TX1L16
121VUATSU 1/SWTG5TX1L15
** ON A/C NOT FOR ALL
121VUCOM NAV/RMP/22RG2L02
121VUAUTO FLT/MCDU/211CA2N20
121VUHYDRAULIC/LGCIU/SYS22GAQ35
121VUEIS/FWC2/SPLY2WWQ07
** ON A/C NOT FOR ALL
121VUCOM/VHF/32RC3L05
** ON A/C NOT FOR ALL
121VUDATA/LOADER/SPLY3TDJ16
** ON A/C NOT FOR ALL
121VUCOM NAV/VHF/32RC3L05
** ON A/C NOT FOR ALL
121VUPDL/PWR/SPLY14TDJ45
121VUCFDS/CFDIU/SPLY2TWJ41
121VUDATA/LOADER/SPLY3TDJ39
121VUATSU 13TX1K43
121VUATSU 1/SWTG5TX1K42
Subtask 46-21-00-860-173-A ** ON A/C NOT FOR ALL
C. Aircraft Maintenance Configuration
   (1) Make sure that the aircraft is in the ground configuration.
Subtask 46-21-00-480-070-A ** ON A/C NOT FOR ALL
D. Get access to the avionics compartment.
   (1) Put an ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position at access door 824 in zone 128.
   (2) Open access door 824
Subtask 46-21-00-480-071-A ** ON A/C NOT FOR ALL
E. Installation of the ALT45200001 PORTABLE DATA LOADER
   (1) Connect the cable between the ALT45200001 PORTABLE DATA LOADER and connector 183VC located at the bottom of electronics rack 80VU.
Subtask 46-21-00-860-174-A ** ON A/C NOT FOR ALL
F. Start the PDL
   (1) Start the ALT45200001 PORTABLE DATA LOADER (Refer to the PDL user guide).
4. Procedure
NOTE: Purpose of this task is to recover 6 ISM files named ISM_FLASH_SYNC, ISM_FLASH_ASYNC1, ISM_FLASH_ASYNC2, ISM_FLASH_ASYNC3, SM_FLASH_ASYNC4, ISM_FLASH_ASYNC5.
NOTE: All 6 ISM files should be recovered regardless of the order.
NOTE: For each file to recover a configuration file named "002_1.lnr" should be used. The file name or contain should not be modified by the operator.
NOTE: A full ATSU downloading is approximately 45 minutes long.
Subtask 46-21-00-970-105-A ** ON A/C NOT FOR ALL
A. Downloading of ATSU ISM files
   (1) Insert in PDL a removable media (e.g USB key) with repositories containing the 0200_1.lnr files.
Or copy in PDL internal memory the different repositories and their contains (refer to the PDL user guide to perform this step).
   (2) On PDL Select the following options :
  • Downloading type : Media Defined Download operation
  • Target system : ATSU
NOTE: Depending on used PDL model some supplementary parameters could be needed to be defined - Refer to the PDL user's guide to set all the parameters requested for a downloading.
   (3) The following procedure should be followed to recover each ISM file (ISM_FLASH_SYNC, ISM_FLASH_ASYNC1, ISM_FLASH_ASYNC2, ISM_FLASH_ASYNC3, ISM_FLASH_ASYNC4, ISM_FLASH_ASYNC5).
     (a) Select in PDL input the file 002_1.lnr located in repository which has the same name as the ISM file to recover.
     (b) Start downloading operation (refer to PDL user guide).
NOTE: The file recovered from ATSU can be stored in PDL internal memory or in removable media connected to PDL (e.g. USB key), depending on PDL capacities or operator preferencies.
     (c) When the ISM file has been recovered go to step (3) in order to download next ISM file.
   (4) When all ISM files have been recovered go to step Stop of the ATSU ISM downloading procedure.
Subtask 46-21-00-860-175-A ** ON A/C NOT FOR ALL
B. Stop of the ATSU ISM downloading procedure
   (1) Stop the PDL (Refer to the portable data-loader user guide).
   (2) Disconnect the cable between the PORTABLE DATA LOADER and connector 183VC located at the bottom of electronics rack 80VU.
NOTE: This cable disconnection will generate an ATSU restart.
   (3) On cockpit make sure that the ATSU prompt comes into view on the MCDU MENU page.
NOTE: Recovered ISM files should be provided to AIRBUS.
5. Close-up
Subtask 46-21-00-410-055-A ** ON A/C NOT FOR ALL
A. Close Access
   (1) Make sure that the work area is clean and clear of tools and other items.
   (2) Close access door 824
   (3) Remove the access platform(s).
Subtask 46-21-00-862-085-A ** ON A/C NOT FOR ALL
B. De-energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-862-002)
[Rev.10 from 2021] 2026.04.02 06:26:03 UTC