Uploading of the ATSU Software Component
TASK 46-21-00-610-001-C
Uploading of the ATSU Software Component
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 46-21-00-861-057-A ** ON A/C NOT FOR ALL Subtask 46-21-00-480-061-C ** ON A/C NOT FOR ALL
Subtask 46-21-00-970-053-A ** ON A/C NOT FOR ALL
Subtask 46-21-00-970-071-H ** ON A/C NOT FOR ALL
Subtask 46-21-00-860-068-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2017]
2026.04.02 06:26:03 UTC
Uploading of the ATSU Software Component
CAUTION:
IF YOU WANT TO UPLOAD THE ATSU SOFTWARE COMPONENTS FROM THE PDL, MAKE SURE THAT THESE SOFTWARE COMPONENTS ARE UPLOADED TO THE PDL. IF YOU DO NOT OBEY THIS PRECAUTION, THERE IS A RISK OF FAILURE OF THE SOFTWARE UPLOADING.
CAUTION:
YOU MUST DO A CHECK OF THE INTEGRITY OF THE MEDIA USED FOR THE SOFTWARE UPLOADING. MAKE SURE THAT YOU CORRECTLY COPIED THE DIRECTORY WITH ALL THE HIDDEN FILES AND FOLDERS. IF YOU DO NOT OBEY THIS PRECAUTION, THERE IS A RISK OF FAILURE OF THE SOFTWARE UPLOADING.
CAUTION:
YOU MUST DO THE UPLOADING OF THE AOC APPLICATION SOFTWARE AND ASSOCIATED DATABASE AFTER UPLOADING OF THE ATSU A/C INTERFACE SOFTWARE. UPLOADING OF THE ATSU A/C INTERFACE SOFTWARE ERASES THE AOC APPLICATION SOFTWARE AND ASSOCIATED DATABASE.
CAUTION:
DO THE UPLOADING OF THE AOC SOFTWARE (22TX) BEFORE YOU DO THE UPLOADING OF THE AOC DATABASE SOFTWARE (24TX).
1. Reason for the JobSelf explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | LOADER - DATA, PORTABLE |
| ALT45200001 | 1 | PORTABLE DATA LOADER |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 210 | CKPT,FWD COMPT BHD TO FLT COMPT BULKHEAD |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-41-00-861-002-A | Energize the Aircraft Electrical Circuits from the External Power |
| TASK 24-41-00-861-002-A-01 | Energize the Aircraft Electrical Circuits from the APU |
| TASK 24-41-00-861-002-A-02 | Energize the Aircraft Electrical Circuits from Engine 1(2) |
| TASK 24-41-00-862-002-A | De-energize the Aircraft Electrical Circuits Supplied from the External Power |
| TASK 24-41-00-862-002-A-01 | De-energize the Aircraft Electrical Circuits Supplied from the APU |
| TASK 24-41-00-862-002-A-02 | De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2) |
| TASK 31-32-00-860-003-A | Procedure to Get Access to the SYSTEM REPORT/TEST/COM Page |
| TASK 31-32-00-860-013-A | Procedure to Get Access to the SYSTEM REPORT/TEST/INFO SYS Page |
Subtask 46-21-00-861-057-A ** ON A/C NOT FOR ALL Subtask 46-21-00-480-061-C ** ON A/C NOT FOR ALL
B. Installation of the PDL
(1) On the overhead panel, on DATA LOADING panel 52VU:
(a) Loosen the two middle quick-release fasteners of the access cover and remove it.
(b) Connect the cable to the ALT45200001 PORTABLE DATA LOADER or LOADER - DATA, PORTABLE and to the DATA LOADER connector (2TD).
Subtask 46-21-00-865-058-A ** ON A/C NOT FOR ALL (1) On the overhead panel, on DATA LOADING panel 52VU:
(a) Loosen the two middle quick-release fasteners of the access cover and remove it.
(b) Connect the cable to the ALT45200001 PORTABLE DATA LOADER or LOADER - DATA, PORTABLE and to the DATA LOADER connector (2TD).
C. Make sure that this(these) circuit breaker(s) is(are) closed:
Subtask 46-21-00-860-110-C ** ON A/C NOT FOR ALL | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 49VU | AUTO FLT/MCDU/1 | 11CA1 | B01 |
| 49VU | L/G/LGCIU/SYS1/NORM | 1GA | C09 |
| 49VU | FWS/FWC1/SPLY | 3WW | F01 |
| ** ON A/C NOT FOR ALL | |||
| 121VU | DATA/LOADER/SPLY | 3TD | J16 |
| ** ON A/C NOT FOR ALL | |||
| 121VU | CFDS/CFDIU/SPLY | 2TW | J18 |
| 121VU | DLS&/DLRB/SPLY | 5TD | J15 |
| 121VU | PDL/PWR/SPLY | 14TD | K19 |
| 121VU | ATSU 1 | 3TX1 | L16 |
| 121VU | ATSU 1/SWTG | 5TX1 | L15 |
| 121VU | AUTO FLT/MCDU/2 | 11CA2 | N20 |
| 121VU | HYDRAULIC/LGCIU/SYS2 | 2GA | Q35 |
| 121VU | EIS/FWC2/SPLY | 2WW | Q07 |
D. Start the PDL
(1) Start the ALT45200001 PORTABLE DATA LOADER or LOADER - DATA, PORTABLE (refer to the PDL user guide).
Subtask 46-21-00-860-067-A ** ON A/C NOT FOR ALL (1) Start the ALT45200001 PORTABLE DATA LOADER or LOADER - DATA, PORTABLE (refer to the PDL user guide).
E. Aircraft Maintenance Configuration
(1) Make sure that the aircraft is in the ground configuration.
(2) On the overhead panel, on the DLS, make sure that the ON/OFF control switch is set to OFF.
Subtask 46-21-00-280-076-A ** ON A/C NOT FOR ALL (1) Make sure that the aircraft is in the ground configuration.
(2) On the overhead panel, on the DLS, make sure that the ON/OFF control switch is set to OFF.
F. Refer to the Logic Diagram before the Uploading of the ATSU A/C INTERFACE Software (Part A)
Logic Diagram to Upload the ATSU Software ** ON A/C NOT FOR ALL
Logic Diagram to Upload the ATSU Software ** ON A/C NOT FOR ALL
Subtask 46-21-00-280-106-C ** ON A/C NOT FOR ALL
Logic Diagram to Upload the ATSU Software ** ON A/C NOT FOR ALL
Logic Diagram to Upload the ATSU Software ** ON A/C NOT FOR ALL G. Check of the Reference(s) of the Software Components (20TX, 21TX and 30TX) Pre-loaded in the ATSU, on the MCDU
(1) Do the procedure to get access to the SYSTEM REPORT/TEST/INFO SYS page (Ref. AMM TASK 31-32-00-860-013).
(2) If the access to the LRU IDENTIFICATION page is not possible (first condition):
Subtask 46-21-00-280-107-E ** ON A/C NOT FOR ALL (1) Do the procedure to get access to the SYSTEM REPORT/TEST/INFO SYS page (Ref. AMM TASK 31-32-00-860-013).
(2) If the access to the LRU IDENTIFICATION page is not possible (first condition):
- Do the uploading procedure of the ATSU software given in Para. 4.
- Do a check of the reference of the software components pre-loaded in the ATSU, on the MCDU:
| ACTION | RESULT |
|---|---|
1.On the MCDU:
| On the MCDU:
|
2.On the ATIMS page:
| On the MCDU:
|
| 3.On the LRU IDENTIFICATION page, before you do the uploading procedure in Para. 4.A: Make sure that the references shown below the software indications are not the same as the references read on the related disk(s):
NOTE: On the disk (20TX), the last number of the ATSU A/C INTERFACE software reference is F1, but on the LRU IDENTIFICATION page, the last number of this reference is 00. |
H. Check of the Reference(s) of the Software Components (ATC Application) Pre-loaded in the ATSU, on the MCDU
(1) Do the procedure to get access to the SYSTEM REPORT/TEST/INFO SYS page (Ref. AMM TASK 31-32-00-860-013).
(2) If the access to the LRU IDENTIFICATION page is not possible (first condition):
Subtask 46-21-00-280-092-B ** ON A/C NOT FOR ALL (1) Do the procedure to get access to the SYSTEM REPORT/TEST/INFO SYS page (Ref. AMM TASK 31-32-00-860-013).
(2) If the access to the LRU IDENTIFICATION page is not possible (first condition):
- Do the uploading procedure of the ATSU software given in Para. 4.
- Do a check of the reference of the software component pre-loaded in the ATSU, on the MCDU:
| ACTION | RESULT |
|---|---|
1.On the MCDU:
| On the MCDU:
|
2.On the ATIMS page:
| On the MCDU:
|
| 3.On the LRU IDENTIFICATION page, before you do the uploading procedure in Para. 4.B.: Make sure that the references shown below the software indications are not the same as the references read on the related disk(s):
|
I. Check of the Reference of the AOC Software Component and AOC DATABASE Software Component Pre-loaded in the ATSU, on the MCDU
Subtask 46-21-00-280-108-C ** ON A/C NOT FOR ALL | ACTION | RESULT |
|---|---|
1.On the MCDU:
| On the MCDU:
|
2.On the MCDU MENU page:
| On the MCDU:
|
3.On the ATSU DATALINK page:
| On the MCDU:
|
4.On the AOC MENU page:
| On the MCDU:
|
5.On the MISC MENU page:
| On the MCDU:
|
| 6.On the SYSTEM CONFIG page: Before you do the uploading procedure in Para. 4.C, make sure that:
|
J. Check of the Reference(s) of the Software Component (31TX) Loaded in the ATSU, on the MCDU
(1) Do the procedure to get access to the SYSTEM REPORT/TEST/INFO SYS page (Ref. AMM TASK 31-32-00-860-013).
(2) If the access to the LRU IDENTIFICATION page is not possible (first condition):
4. Procedure(1) Do the procedure to get access to the SYSTEM REPORT/TEST/INFO SYS page (Ref. AMM TASK 31-32-00-860-013).
(2) If the access to the LRU IDENTIFICATION page is not possible (first condition):
- Do the uploading procedure of the ATSU software given in Para. 4.
- Do a check of the reference of the software component loaded in the ATSU, on the MCDU:
| ACTION | RESULT |
|---|---|
1.On the MCDU:
| On the MCDU:
|
2.On the ATIMS page:
| On the MCDU:
|
| 3.On the LRU IDENTIFICATION page, before you do the uploading procedure in Para. 4.D.: Make sure that the reference shown below the software indication is not the same as the reference read on the related disk:
|
Subtask 46-21-00-970-053-A ** ON A/C NOT FOR ALL
A. Uploading of the ATSU Software Components (20TX, 21TX and 30TX)
Subtask 46-21-00-970-053-C ** ON A/C NOT FOR ALL CAUTION:
DURING THE UPLOADING OF THE SOFTWARE COMPONENTS TO THE ATSU (FIN'S 20TXSW1, 21TXSW1, 30TXSW1, 23TXSW1, 25TXSW1, 35TXSW1, 36TXSW1, 39TXSW1, 37TXSW1, 22TXSW1, 24TXSW1, 31TXSW1, 42TXSW1), MAKE SURE THAT: IF YOU DO NOT OBEY THESE TWO PRECAUTIONS, THERE CAN BE ERASURE OF ALL THE SOFTWARE COMPONENTS LOADED INTO THE ATSU. IT CAN THEN BE NECESSARY TO START THE UPLOADING PROCEDURE OF ALL THE ATSU SOFTWARE COMPONENTS AGAIN.
(1) Print the COMM CONFIG and VHF3 SCAN SELECT pages before you upload the ATSU software (Ref. AMM TASK 31-32-00-860-003) (Ref. AMM TASK 31-32-00-860-013). -
MAINTENANCE PERSONNEL DO NOT CHANGE THE SOURCE OF THE AIRCRAFT POWER SUPPLY (GROUND POWER UNIT, APU, ETC.) - MAINTENANCE PERSONNEL DO NOT TOUCH OR MOVE THE DATA LOADER SELECTOR(S)/DLRB AND THE MDDU/PDL.
NOTE: The uploading sequence is as follows:
- First, the ATSU A/C INTERFACE software component (20TX)
- Then, the ATSU CONFIGURATION software component (21TX) and the ATSU ROUTER PARAMETERS software component (30TX).
NOTE: The loading time for a full disk changes in relation to the software. The maximum loading time is 40 minutes.
(2) On the DLS, set the ON/OFF control switch to OFF position between each software uploading procedure. The ATSU does a Power On Self-Test (POST) to validate each uploading and to make sure that the software is operational. NOTE: After the uploading procedures, it is necessary to do a check of the reference of the data loaded in the computer, on the MCDU.
NOTE: When you upload software component 30TX, if the P/Ns of software components 20TX and 30TX are not compatible, it is necessary to upload ATSU software components 20TX and 21TX again.
| ACTION | RESULT |
|---|---|
1.On the overhead panel, on the DLS:
| On the display of the DLS:
|
| | On the MDDU:
|
2.On the overhead panel, on the DLS:
| On the display of the DLS:
|
3.On the overhead panel, on the DLS:
| On the display of the DLS:
|
| | On the MDDU:
|
4.On the MDDU:
| On the MDDU:
|
| | On the MDDU:
|
5.If the TRANS IN PROG indication is not shown after a short time:
| |
6.If a transfer fault occurs, wait for a minimum of three minutes:
| On the upper ECAM DU:
|
| | On the MCDU:
NOTE: If more than one disk is necessary for the uploading, the EJECT DISK and INSERT DISK indications are shown one after the other. They tell the operator to put a new disk into the MDDU
NOTE: If more than one disk is necessary to do the uploading and if a transfer fault occurs, it is necessary to do the uploading again (i.e. from disk 1). |
7.On the overhead panel, on the DLS:
| On the display of the DLS:
|
8.On the MDDU:
| On the MDDU:
|
9.On the overhead panel, on the DLS:
| On the upper ECAM DU:
NOTE: When the ON/OFF control switch on the DLS is set to OFF, the ATSU does a power on self-test. The DATALINK ATSU FAULT warning goes out of view at the end of the test. |
If the DATALINK ATSU FAULT warning stays displayed at the end of the test:
| |
On the MCDU MENU page:
NOTE: If the ATSU router is not initialized, the DATALINK ATSU FAULT + ATSU INIT FAULT warning comes into view on the upper ECAM DU. |
CAUTION:
DURING THE UPLOADING OF THE SOFTWARE COMPONENTS TO THE ATSU (FIN'S 20TXSW1, 21TXSW1, 30TXSW1, 23TXSW1, 25TXSW1, 35TXSW1, 36TXSW1, 39TXSW1, 37TXSW1, 22TXSW1, 24TXSW1, 31TXSW1, 42TXSW1), MAKE SURE THAT: IF YOU DO NOT OBEY THESE TWO PRECAUTIONS, THERE CAN BE ERASURE OF ALL THE SOFTWARE COMPONENTS LOADED INTO THE ATSU. IT CAN THEN BE NECESSARY TO START THE UPLOADING PROCEDURE OF ALL THE ATSU SOFTWARE COMPONENTS AGAIN.
A. Uploading of the ATSU Software Components (20TX, 21TX and 30TX) (with the PDL through ARINC 615) -
MAINTENANCE PERSONNEL DO NOT CHANGE THE SOURCE OF THE AIRCRAFT POWER SUPPLY (GROUND POWER UNIT, APU, ETC.) - MAINTENANCE PERSONNEL DO NOT TOUCH OR MOVE THE DATA LOADER SELECTOR(S)/DLRB AND THE MDDU/PDL.
NOTE: This procedure is used to upload software to the ATSU with the PDL.
NOTE: If the PDL has the digital signature check, the PDL can send two messages:
(1) Print the COMM CONFIG and VHF3 SCAN SELECT pages before you upload the ATSU software (Ref. AMM TASK 31-32-00-860-003) (Ref. AMM TASK 31-32-00-860-013). - One if the PDL detects that the software is not signed (refer to PDL user guide), you can ignore this message. It has no effect on the aircraft software uploading.
- One if the PDL detects an incorrect or corrupted signature (refer to PDL user guide), then the software uploading will not be possible and it will be necessary to use a different software.
NOTE: The uploading sequence is as follows:
- The ATSU A/C INTERFACE software component (20TX)
- The ATSU CONFIGURATION software component (21TX)
- The ATSU ROUTER PARAMETERS software component (30TX).
NOTE: The loading time for a full disk changes in relation to the software. The maximum loading time is 40 minutes.
NOTE: On the DLS, set the ON/OFF control switch to OFF position between each software uploading procedure. The ATSU does a Power On Self-Test (POST) to validate each uploading and to make sure that the software is operational.
NOTE: After the uploading procedures, it is necessary to do a check of the reference of the data loaded in the computer, on the MCDU.
NOTE: When you upload software component 30TX, if the P/Ns of software components 20TX and 30TX are not compatible, it is necessary to upload ATSU software components 20TX and 21TX again.
| ACTION | RESULT |
|---|---|
1.On the overhead panel, on the DLS:
| On the display of the DLS:
|
2.On the overhead panel, on the DLS:
| On the display of the DLS:
|
3.On the overhead panel, on the DLS:
| On the display of the DLS:
|
| 4.Upload the ATSU Software (refer to the PDL user guide). | |
5.On the overhead panel, on the DLS:
| On the display of the DLS:
|
6.On the overhead panel, on the DLS:
| On the upper ECAM DU:
NOTE: When the ON/OFF control switch on the DLS is set to OFF, the ATSU does a power on self-test. The DATALINK ATSU FAULT warning goes out of view at the end of the test. |
7.If the DATALINK ATSU FAULT warning stays displayed after one minute:
| |
On the MCDU MENU page:
NOTE: If the ATSU router is not initialized, the DATALINK ATSU FAULT + ATSU INIT FAULT warning comes into view on the upper ECAM DU. |
B. Uploading of the ATSU ATC Applications
(1) Print the COMM CONFIG and VHF3 SCAN SELECT pages before you upload the ATSU software (Ref. AMM TASK 31-32-00-860-003) (Ref. AMM TASK 31-32-00-860-013).
Subtask 46-21-00-970-072-B ** ON A/C NOT FOR ALL (1) Print the COMM CONFIG and VHF3 SCAN SELECT pages before you upload the ATSU software (Ref. AMM TASK 31-32-00-860-003) (Ref. AMM TASK 31-32-00-860-013).
NOTE: The uploading sequence is as follows:
- ATC HMI UTILITIES software component (25TX)
- ATSU FANS B APPLICATIONS software component (36TX)
- ATSU CMA CONFIGURATION software component (37TX).
NOTE: The loading time for a full disk is approximately 12 minutes.
NOTE: After the uploading procedures, it is necessary to do a check of the reference of the data loaded in the computer, on the MCDU.
| ACTION | RESULT |
|---|---|
1.On the overhead panel, on the DLS:
| On the display of the DLS:
|
2.On the overhead panel, on the DLS:
| On the display of the DLS:
|
3.On the overhead panel, on the DLS:
| On the display of the DLS:
|
| 4.Upload the ATSU Software (Refer to the PDL user guide). | |
5.On the overhead panel, on the DLS:
| On the display of the DLS:
|
6.On the overhead panel, on the DLS:
| On the upper ECAM DU:
NOTE: When the ON/OFF control switch on the DLS is set to OFF, the ATSU does a power on self-test. The COM ACARS FAULT or DATALINK ATSU FAULT warning goes out of view at the end of the test. |
| | On the MCDU MENU page:
NOTE: If the ATSU router is not initialized, the ACARS STBY memo or the DATALINK ATSU FAULT + ATSU INIT FAULT warning comes into view on the upper ECAM DU. |
| 7.Do the same operation again for each set of application disks that you must upload. |
C. Uploading of the ATSU AOC Applications
Subtask 46-21-00-970-072-C ** ON A/C NOT FOR ALL CAUTION:
DURING THE UPLOADING OF THE SOFTWARE COMPONENTS TO THE ATSU (FIN'S 20TXSW1, 21TXSW1, 30TXSW1, 23TXSW1, 25TXSW1, 35TXSW1, 36TXSW1, 39TXSW1, 37TXSW1, 22TXSW1, 24TXSW1, 31TXSW1, 42TXSW1), MAKE SURE THAT: IF YOU DO NOT OBEY THESE TWO PRECAUTIONS, THERE CAN BE ERASURE OF ALL THE SOFTWARE COMPONENTS LOADED INTO THE ATSU. IT CAN THEN BE NECESSARY TO START THE UPLOADING PROCEDURE OF ALL THE ATSU SOFTWARE COMPONENTS AGAIN.
(1) Print the COMM CONFIG and VHF3 SCAN SELECT pages before you upload the ATSU software (Ref. AMM TASK 31-32-00-860-003) (Ref. AMM TASK 31-32-00-860-013). -
MAINTENANCE PERSONNEL DO NOT CHANGE THE SOURCE OF THE AIRCRAFT POWER SUPPLY (GROUND POWER UNIT, APU, ETC.) - MAINTENANCE PERSONNEL DO NOT TOUCH OR MOVE THE DATA LOADER SELECTOR(S)/DLRB AND THE MDDU/PDL.
NOTE: The uploading sequence is as follows:
- First, the AOC software component (22TX)
- Then, the AOC database component (24TX).
NOTE: The loading time for a full disk is 40 minutes maximum.
NOTE: After the uploading procedures, it is necessary to do a check of the reference of the data loaded in the computer, on the MCDU.
NOTE: During the uploading of the customized software component (24TX), if you disconnect the MDDU before the TRANSF COMPLETE or TRANSF FAILED indication is shown:
- It will be necessary to upload again all the software loaded in the ATSU (this is not applicable to FIN 20TX).
NOTE: If software components 22TX and 24TX were uploaded, then it is necessary to upload:
- First, ATSU A/C INTERFACE software component (20TX)
- Then, all the other ATSU software components.
| ACTION | RESULT |
|---|---|
1.On the overhead panel, on the DLS:
| On the display of the DLS:
|
| | On the MDDU:
|
2.On the overhead panel, on the DLS:
| On the display of the DLS:
|
3.On the overhead panel, on the DLS:
| On the display of the DLS:
|
| | On the MDDU:
|
4.On the MDDU:
| On the MDDU:
|
| | On the MDDU:
|
5.If a transfer fault occurs, wait for a minimum of three minutes:
NOTE: If more than one disk is necessary for the uploading, the EJECT DISK and INSERT DISK indications are shown one after the other. They tell the operator to put a new disk into the MDDU. NOTE: If more than one disk is necessary to do the uploading and if a transfer fault occurs, it is necessary to do the uploading again (i.e. from disk 1). | |
| | On the upper ECAM DU:
|
| | On the MCDU:
|
On the MDDU:
| |
6.On the overhead panel, on the DLS:
| On the display of the DLS:
|
7.On the MDDU:
| On the MDDU:
|
8.On the overhead panel, on the DLS:
| On the upper ECAM DU:
NOTE: When the ON/OFF control switch on the DLS is set to OFF, the ATSU does a power on self-test. The COM ACARS FAULT or DATALINK ATSU FAULT warning goes out of view at the end of the test. |
| | On the MCDU MENU page:
NOTE: If the ATSU router is not initialized, the ACARS STBY memo or the DATALINK ATSU FAULT + ATSU INIT FAULT warning comes into view on the upper ECAM DU. |
| 9.Do the same operation again for each set of application disks that you must upload. |
C. Uploading of the ATSU AOC Applications
Subtask 46-21-00-970-073-B ** ON A/C NOT FOR ALL CAUTION:
DURING THE UPLOADING OF THE SOFTWARE COMPONENTS TO THE ATSU (FIN'S 20TXSW1, 21TXSW1, 30TXSW1, 23TXSW1, 25TXSW1, 35TXSW1, 36TXSW1, 39TXSW1, 37TXSW1, 22TXSW1, 24TXSW1, 31TXSW1, 42TXSW1), MAKE SURE THAT: IF YOU DO NOT OBEY THESE TWO PRECAUTIONS, THERE CAN BE ERASURE OF ALL THE SOFTWARE COMPONENTS LOADED INTO THE ATSU. IT CAN THEN BE NECESSARY TO START THE UPLOADING PROCEDURE OF ALL THE ATSU SOFTWARE COMPONENTS AGAIN.
(1) Print the COMM CONFIG and VHF3 SCAN SELECT pages before you upload the ATSU software (Ref. AMM TASK 31-32-00-860-003) (Ref. AMM TASK 31-32-00-860-013). -
MAINTENANCE PERSONNEL DO NOT CHANGE THE SOURCE OF THE AIRCRAFT POWER SUPPLY (GROUND POWER UNIT, APU, ETC.) - MAINTENANCE PERSONNEL DO NOT TOUCH OR MOVE THE DATA LOADER SELECTOR(S)/DLRB AND THE MDDU/PDL.
NOTE: The uploading sequence is as follows:
- First, the AOC software component (22TX)
- Then, the AOC database software component (24TX).
NOTE: The maximum loading time for a full disk is 40 minutes.
NOTE: After the uploading procedures, it is necessary for the operator to do a check of the reference of the data loaded in the computer, on the MCDU.
NOTE: During the uploading of the customized software component (24TX), if you disconnect the PDL before the TRANSF COMPLETE or TRANSF FAILED indication is shown:
- It will be necessary to upload all the software loaded in the ATSU (this is applicable to FIN 20TX).
NOTE: If software components 22TX and 24TX were uploaded, then it is necessary to upload:
- First, ATSU A/C INTERFACE software component (20TX)
- Then, all the other ATSU software components.
| ACTION | RESULT |
|---|---|
1.On the overhead panel, on the DLS:
| On the display of the DLS:
|
2.On the overhead panel, on the DLS:
| On the display of the DLS:
|
3.On the overhead panel, on the DLS:
| On the display of the DLS:
|
| 4.Upload the ATSU software (refer to the PDL user guide). | |
5.On the overhead panel, on the DLS:
| On the display of the DLS:
|
6.On the overhead panel, on the DLS:
| On the upper ECAM DU:
NOTE: When the ON/OFF control switch on the DLS is set to OFF, the ATSU does a power on self-test. The COM ACARS FAULT or DATALINK ATSU FAULT warning goes out of view at the end of the test. |
| | On the MCDU MENU page:
NOTE: If the ATSU router is not initialized, the ACARS STBY memo or the DATALINK ATSU FAULT + ATSU INIT FAULT warning comes into view on the upper ECAM DU. |
| 7.Do the same operation again for each set of application disks that you must upload. |
D. Uploading of the ATSU ISM Applications
(1) Print the COMM CONFIG and VHF3 SCAN SELECT pages before you upload the ATSU software (Ref. AMM TASK 31-32-00-860-003) (Ref. AMM TASK 31-32-00-860-013).
Subtask 46-21-00-970-073-C ** ON A/C NOT FOR ALL (1) Print the COMM CONFIG and VHF3 SCAN SELECT pages before you upload the ATSU software (Ref. AMM TASK 31-32-00-860-003) (Ref. AMM TASK 31-32-00-860-013).
NOTE: The uploading sequence is as follows:
- First, ATSU ISM related to the ATSU ISM APPLICATION software component 31TX
- Then, all the other ATSU software components.
NOTE: The loading time for a full disk is approximately 12 minutes.
NOTE: After the uploading procedures, it is necessary to do a check of the reference of the data loaded in the computer, on the MCDU.
| ACTION | RESULT |
|---|---|
1.On the overhead panel, on the DLS:
| On the display of the DLS:
|
| | On the MDDU:
|
2.On the overhead panel, on the DLS:
| On the display of the DLS:
|
3.On the overhead panel, on the DLS:
| On the display of the DLS:
|
| | On the MDDU:
|
4.On the MDDU:
| On the MDDU:
|
| | On the MDDU:
|
5.If a transfer fault occurs, wait for a minimum of three minutes:
NOTE: If more than one disk is necessary for the uploading, the EJECT DISK and INSERT DISK indications are shown one after the other. They tell the operator to put a new disk into the MDDU. NOTE: If more than one disk is necessary to do the uploading and if a transfer fault occurs, it is necessary to do the uploading again (from disk 1). | On the upper ECAM DU:
|
| | On the MCDU:
|
On the MDDU:
| |
6.On the overhead panel, on the DLS:
| On the display of the DLS:
|
7.On the MDDU:
| On the MDDU:
|
8.On the overhead panel, on the DLS:
| On the upper ECAM DU:
NOTE: When the ON/OFF control switch on the DLS is set to OFF, the ATSU does a power-on self-test. The COM ACARS FAULT or DATALINK ATSU FAULT warning goes out of view at the end of the test. |
| | On the MCDU MENU page:
NOTE: If the ATSU router is not initialized, the ACARS STBY memo or the DATALINK ATSU FAULT + ATSU INIT FAULT warning comes into view on the upper ECAM DU. |
| 9.Do the same procedure again for each set of application disks that you must upload. |
D. Uploading of the ATSU ISM Applications
(1) Print the COMM CONFIG and VHF3 SCAN SELECT pages before you upload the ATSU software (Ref. AMM TASK 31-32-00-860-003) (Ref. AMM TASK 31-32-00-860-013).
Subtask 46-21-00-280-109-C ** ON A/C NOT FOR ALL (1) Print the COMM CONFIG and VHF3 SCAN SELECT pages before you upload the ATSU software (Ref. AMM TASK 31-32-00-860-003) (Ref. AMM TASK 31-32-00-860-013).
NOTE: The loading time for a full disk is approximately 12 minutes.
NOTE: After the uploading procedures, it is necessary to do a check of the reference of the data loaded in the computer, on the MCDU.
| ACTION | RESULT |
|---|---|
1.On the overhead panel, on the DLS:
| On the display of the DLS:
|
2.On the overhead panel, on the DLS:
| On the display of the DLS:
|
3.On the overhead panel, on the DLS:
| On the display of the DLS:
|
| 4.Upload the ATSU Software (Refer to PDL user guide). | |
5.On the overhead panel, on the DLS:
| On the display of the DLS:
|
6.On the overhead panel, on the DLS:
| On the upper ECAM DU:
NOTE: When the ON/OFF control switch on the DLS is set to OFF, the ATSU does a power on self-test. The COM ACARS FAULT or DATALINK ATSU FAULT warning goes out of view at the end of the test. |
| | On the MCDU MENU page:
NOTE: If the ATSU router is not initialized, the ACARS STBY memo or the DATALINK ATSU FAULT + ATSU INIT FAULT warning comes into view on the upper ECAM DU. |
E. Check of the Reference(s) of the Software Components (20TX, 21TX and 30TX) Uploaded in the ATSU, on the MCDU
(2) Do a check of the reference of the software components uploaded in the ATSU, on the MCDU:
Subtask 46-21-00-280-110-E ** ON A/C NOT FOR ALL NOTE: Approximately one minute is necessary for the ATSU software to be operational after the uploading procedure.
(1) Do the procedure to get access to the SYSTEM REPORT/TEST/INFO SYS page (Ref. AMM TASK 31-32-00-860-013). (2) Do a check of the reference of the software components uploaded in the ATSU, on the MCDU:
| ACTION | RESULT |
|---|---|
1.On the MCDU:
| On the MCDU:
|
2.On the ATIMS page:
| On the MCDU:
|
| 3.On the LRU IDENTIFICATION page: Make sure that the references shown below the related software indications are the same as the references read on the disk(s) uploaded in the ATSU:
NOTE: On the disk (20TX), the last number of the ATSU A/C INTERFACE software reference is F1, but on the LRU IDENTIFICATION page, the last number of this reference is 00. |
F. Check of the Reference(s) of the Software Components (ATC Application) Uploaded in the ATSU, on the MCDU
(2) Do a check of the reference of the software components uploaded in the ATSU, on the MCDU:
Subtask 46-21-00-280-093-B ** ON A/C NOT FOR ALL NOTE: Approximately one minute is necessary for the ATSU software to be operational after the uploading procedure.
(1) Do the procedure to get access to the SYSTEM REPORT/TEST/INFO SYS page (Ref. AMM TASK 31-32-00-860-013). (2) Do a check of the reference of the software components uploaded in the ATSU, on the MCDU:
| ACTION | RESULT |
|---|---|
1.On the MCDU:
| On the MCDU:
|
2.On the ATIMS page:
| On the MCDU:
|
| 3.On the LRU IDENTIFICATION page: Make sure that the references shown below the related software indications are the same as the references read on the disk(s) uploaded in the ATSU:
|
G. Check of the Reference of the AOC Software Component and AOC DATABASE Software Component Uploaded in the ATSU, on the MCDU
Subtask 46-21-00-280-111-C ** ON A/C NOT FOR ALL NOTE: Approximately one minute is necessary for the ATSU software to be operational after the uploading procedure.
| ACTION | RESULT |
|---|---|
1.On the MCDU:
| On the MCDU:
|
2.On the MCDU MENU page:
| On the MCDU:
|
3.On the ATSU DATALINK page:
| On the MCDU:
|
4.On the AOC MENU page:
| On the MCDU:
|
5.On the MISC MENU page:
| On the MCDU:
|
6.On the SYSTEM CONFIG page:
NOTE: After the AOC Database uploading, one or more part numbers XX2T0DXXXXXXXXX with the ATSU A/C INTERFACE DB/N or SA identification can be shown on the LRU IDENT page. |
H. Check of the Reference(s) of the Software Component (31TX) Uploaded in the ATSU, on the MCDU
(2) Do a check of the reference of the software component uploaded in the ATSU, on the MCDU:
Subtask 46-21-00-860-111-C ** ON A/C NOT FOR ALL NOTE: Approximately one minute is necessary for the ATSU software until it can operate after the uploading procedure.
(1) Do the procedure to get access to the SYSTEM REPORT/TEST/INFO SYS page (Ref. AMM TASK 31-32-00-860-013). (2) Do a check of the reference of the software component uploaded in the ATSU, on the MCDU:
| ACTION | RESULT |
|---|---|
1.On the MCDU:
| On the MCDU:
|
2.On the ATIMS page:
| On the MCDU:
|
| 3.On the LRU IDENTIFICATION page: Make sure that the reference shown below the related software indication is the same as the reference on the disk(s) uploaded in the ATSU:
|
I. Stop the PDL
(1) Stop the ALT45200001 PORTABLE DATA LOADER or LOADER - DATA, PORTABLE (refer to the PDL user guide).
Subtask 46-21-00-080-063-C ** ON A/C NOT FOR ALL (1) Stop the ALT45200001 PORTABLE DATA LOADER or LOADER - DATA, PORTABLE (refer to the PDL user guide).
J. Removal of the PDL
(1) On the overhead panel, on DATA LOADING panel 52VU:
(a) Disconnect the cable from the ALT45200001 PORTABLE DATA LOADER or LOADER - DATA, PORTABLE and from the DATA LOADER connector (2TD).
(b) Install the access cover and tighten the two middle quick-release fasteners.
5. Close-up(1) On the overhead panel, on DATA LOADING panel 52VU:
(a) Disconnect the cable from the ALT45200001 PORTABLE DATA LOADER or LOADER - DATA, PORTABLE and from the DATA LOADER connector (2TD).
(b) Install the access cover and tighten the two middle quick-release fasteners.
Subtask 46-21-00-860-068-A ** ON A/C NOT FOR ALL
A. Put the aircraft back to its initial configuration.
(1) On the MCDU, push the line select key adjacent to the RETURN indication until the CFDS menu page comes into view.
(2) On the MCDU, fully decrease the intensity of light of the MCDU screen (display off).
(3) Put the disk(s) in the storage box.
Subtask 46-21-00-862-056-A ** ON A/C NOT FOR ALL (1) On the MCDU, push the line select key adjacent to the RETURN indication until the CFDS menu page comes into view.
(2) On the MCDU, fully decrease the intensity of light of the MCDU screen (display off).
(3) Put the disk(s) in the storage box.