W DOC AIRBUS | AMM A320F

Download Engineering Data to the USB flash drive with the Maintenance Laptop


TASK 44-33-00-720-811-A
Download Engineering Data to the USB flash drive with the Maintenance Laptop


ZONE: 200
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
200
UPPER HALF FUSELAGE
 B. Referenced Information
REFERENCE
DESIGNATION
TASK 24-41-00-861-002-A
Energize the Aircraft Electrical Circuits from the External Power
TASK 24-41-00-861-002-A-01
Energize the Aircraft Electrical Circuits from the APU
TASK 24-41-00-861-002-A-02
Energize the Aircraft Electrical Circuits from Engine 1(2)
TASK 24-41-00-862-002-A
De-energize the Aircraft Electrical Circuits Supplied from the External Power
TASK 24-41-00-862-002-A-01
De-energize the Aircraft Electrical Circuits Supplied from the APU
TASK 24-41-00-862-002-A-02
De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2)
TASK 46-41-00-720-822-A
Download Engineering Data to the USB flash drive with the Maintenance Laptop
TASK 46-41-00-860-801-A
Connection of the Maintenance Laptop to the Cabin Plug
3. Job Set-up
Subtask 44-33-00-861-103-A ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
   (1) Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002)
   (2) Connect the maintenance laptop to the cabin plug (Ref. AMM TASK 46-41-00-860-801).
Subtask 44-33-00-865-104-A ** ON A/C NOT FOR ALL
B. Make sure that this(these) circuit breaker(s) is(are) closed:
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
2000VUWAP27MHD07
2000VUCINS-HESU21RFE02
4. Procedure
Subtask 44-33-00-720-062-A ** ON A/C NOT FOR ALL
A. Download the Engineering Data to the USB flash drive with the Maintenance Laptop (Ref. AMM TASK 46-41-00-720-822).
5. Close-up
Subtask 44-33-00-862-103-A ** ON A/C NOT FOR ALL
A. Put the aircraft back to its initial configuration.
   (1) Remove the ground support and maintenance equipment, the special and standard tools and all other items.
   (2) Shut down the maintenance laptop and disconnect it from the cabin plug.
NOTE: It is not necessary to shut down or disconnect the maintenance laptop, if you continue with a different procedure.
   (3) De-energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-862-002).
[Rev.10 from 2021] 2026.04.02 06:26:02 UTC