W DOC AIRBUS | AMM A320F

Functional Test of the Pressure Switch


TASK 38-42-00-720-001-A
Functional Test of the Pressure Switch


1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
1
ACCESS PLATFORM 2M (6 FT)
No specific
1
GAGE 5 BAR (75 PSI) - PRESSURE
No specific
AR
SAFETY CLIP - CIRCUIT BREAKER
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
162DW
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 12-15-38-613-001-A
Fill the Potable Water Tank System (Aircraft Electrical Power Available)
TASK 24-41-00-861-002-A
Energize the Aircraft Electrical Circuits from the External Power
TASK 24-41-00-861-002-A-01
Energize the Aircraft Electrical Circuits from the APU
TASK 24-41-00-861-002-A-02
Energize the Aircraft Electrical Circuits from Engine 1(2)
TASK 24-41-00-862-002-A
De-energize the Aircraft Electrical Circuits Supplied from the External Power
TASK 24-41-00-862-002-A-01
De-energize the Aircraft Electrical Circuits Supplied from the APU
TASK 24-41-00-862-002-A-02
De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2)
TASK 25-55-12-000-001-A
Removal of the Aft Cargo-Compartment Partition at FR65
TASK 25-55-12-400-001-A
Installation of the Aft Cargo-Compartment Partition at FR65
TASK 52-30-00-860-001-A
Open the FWD or Aft Cargo-Compartment Door with the Yellow Electric Pump
TASK 52-30-00-860-002-A
Close the FWD or Aft Cargo-Compartment Door with the Yellow Electric Pump
3. Job Set-up
Subtask 38-42-00-861-056-A ** ON A/C NOT FOR ALL
A. Energize the aircraft electrical circuit (Ref. AMM TASK 24-41-00-861-002).
Subtask 38-42-00-010-056-C ** ON A/C NOT FOR ALL
B. Get Access
   (1) Open the aft cargo-compartment door (Ref. AMM TASK 52-30-00-860-001).
   (2) Put an ACCESS PLATFORM 2M (6 FT) at the aft cargo-compartment door.
   (3) Remove partition 162DW (Ref. AMM TASK 25-55-12-000-001).
Subtask 38-42-00-865-060-A ** ON A/C NOT FOR ALL
C. Open, safety and tag this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
2001VUWATER SYS-AIR-COMPRESSOR19MDF01
Subtask 38-42-00-480-051-A ** ON A/C NOT FOR ALL
D. Connect a GAGE 5 BAR (75 PSI) - PRESSURE:
  • To the test port installed on top of the potable water tank. Use a T-connection to connect it, or
  • To the test port installed at the pressure reducing and relief valve.
Subtask 38-42-00-865-061-A ** ON A/C NOT FOR ALL
E. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
2001VUWATER SYS-AIR-COMPRESSOR19MDF01
Subtask 38-42-00-613-053-A ** ON A/C NOT FOR ALL
F. Fill the potable water tank (Ref. AMM TASK 12-15-38-613-001).
4. Procedure
Subtask 38-42-00-720-050-B ** ON A/C NOT FOR ALL
A. Do this test.
NOTE: Before you start the test, make sure that there are no leaks in the compressor.
ACTION
RESULT
1.In an aft lavatory:
  • Turn the water faucet to the open to release the pressure in the potable water system.
  • Close the water faucet again when the pressure is released.
In the lavatory:
  • Water flows into the wash basin.
  • The flow rate of the water decreases.
2.At service panel 2023VU:
  • Push and hold limit switch 5MA until the manometer shows 25 psi (1.7237 bar).
In the air boost system:
  • Pressure switch 10MD closes.
  • Relay 9MD is energized.
  • Air compressor 8MD starts to operate.
  • The potable water system starts to pressurize.

In the lavatory:
  • The water flow increases.
3.At service panel 2023VU:
  • Continue to hold limit switch 5MA pushed in.
In the air boost system:
  • When the manometer shows 28 psi (1.9305 bar)
  • Pressure switch 10MD opens.
  • Relay 9MD is de-energized.
  • The operation of air compressor 8MD stops.
4.Do step 1 to 3 again and make sure that the air compressor:
  • Starts at 25 psi (1.7237 bar)
  • Stops at 28 psi (1.9305 bar).

5.At service panel 2023VU:
  • Release limit switch 5MA.
In the air boost system:
  • Relay 9MD is de-energized.
  • Air compressor 8MD does not operate.
5. Close-up
Subtask 38-42-00-080-051-A ** ON A/C NOT FOR ALL
A. Remove the pressure gauge and install the blanking plug on the test connection.
Subtask 38-42-00-613-054-A ** ON A/C NOT FOR ALL
B. If necessary fill the potable water tank (Ref. AMM TASK 12-15-38-613-001).
Subtask 38-42-00-410-056-C ** ON A/C NOT FOR ALL
C. Close Access
   (1) Make sure that the work area is clean and clear of tools and other items.
   (2) Install partition 162DW (Ref. AMM TASK 25-55-12-400-001).
   (3) Close the aft cargo-compartment door (Ref. AMM TASK 52-30-00-860-002).
   (4) Remove the access platform(s).
Subtask 38-42-00-862-056-A ** ON A/C NOT FOR ALL
D. De-energize the aircraft electrical circuit (Ref. AMM TASK 24-41-00-862-002).