Removal of the Shuttle Valve
TASK 38-41-44-000-001-A
Removal of the Shuttle Valve
Self Explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 38-41-44-861-050-A Subtask 38-41-44-614-050-A Subtask 38-41-44-941-050-A
Subtask 38-41-44-020-050-A
[Rev.10 from 2021]
2026.04.02 06:26:00 UTC
Removal of the Shuttle Valve
WARNING:
MAKE SURE THAT THE PNEUMATIC SYSTEM IS DEPRESSURIZED BEFORE YOU START WORK. PRESSURIZED AIR CAN CAUSE INJURY TO PERSONNEL.
1. Reason for the JobSelf Explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE |
| No specific | 1 | PLUG - BLANKING |
| No specific | AR | SAFETY CLIP - CIRCUIT BREAKER |
| No specific | 1 | WARNING NOTICE(S) |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 130 | FWD CARGO COMPT AFT BULKHEAD OF AVNCS COMPT TO FWD PRESSURE BULKHEAD OF WING CENTER BOX |
| 170 | AFT CAB U/FLOOR COMPT AFT BHD OF BULK |
| 131PW | |
| 161DW |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-41-00-861-002-A | Energize the Aircraft Electrical Circuits from the External Power |
| TASK 24-41-00-861-002-A-01 | Energize the Aircraft Electrical Circuits from the APU |
| TASK 24-41-00-861-002-A-02 | Energize the Aircraft Electrical Circuits from Engine 1(2) |
| TASK 25-54-12-000-001-A | Removal of the Forward Cargo-Compartment Partition |
| TASK 25-55-12-000-001-A | Removal of the Aft Cargo-Compartment Partition at FR65 |
| TASK 38-10-00-614-002-A | Depressurization of the Potable Water System |
| TASK 52-30-00-860-001-A | Open the FWD or Aft Cargo-Compartment Door with the Yellow Electric Pump |
| TASK 52-30-00-860-003-A | Open the FWD or Aft Cargo-Compartment Door with the Hand Pump |
Subtask 38-41-44-861-050-A Subtask 38-41-44-614-050-A Subtask 38-41-44-941-050-A
C. Safety Precautions
(1) Put a WARNING NOTICE(S) in position to tell persons not to pressurize the potable water system.
Subtask 38-41-44-865-050-A (1) Put a WARNING NOTICE(S) in position to tell persons not to pressurize the potable water system.
D. Open, safety and tag this(these) circuit breaker(s):
Subtask 38-41-44-010-050-A ** ON A/C NOT FOR ALL | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 2001VU | WATER SYS-AIR-COMPRESSOR | 19MD | F01 |
E. Get Access
(1) Open the aft cargo-compartment door (Ref. AMM TASK 52-30-00-860-001) (Ref. AMM TASK 52-30-00-860-003).
(2) Put the ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position.
(3) Remove partition 161DW (Ref. AMM TASK 25-55-12-000-001).
Subtask 38-41-44-010-050-B ** ON A/C NOT FOR ALL (1) Open the aft cargo-compartment door (Ref. AMM TASK 52-30-00-860-001) (Ref. AMM TASK 52-30-00-860-003).
(2) Put the ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position.
(3) Remove partition 161DW (Ref. AMM TASK 25-55-12-000-001).
E. Get Access
(1) Open the forward cargo-compartment door (Ref. AMM TASK 52-30-00-860-001) (Ref. AMM TASK 52-30-00-860-003).
(2) Put the ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position.
(3) Remove partition 131PW (Ref. AMM TASK 25-54-12-000-001).
4. Procedure(1) Open the forward cargo-compartment door (Ref. AMM TASK 52-30-00-860-001) (Ref. AMM TASK 52-30-00-860-003).
(2) Put the ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position.
(3) Remove partition 131PW (Ref. AMM TASK 25-54-12-000-001).
Subtask 38-41-44-020-050-A
A. Removal of Shuttle Valve 4215MM
(2) If necessary, remove the nut (6), the screw (3), the washer (4) and the clamp (5).
(3) Remove shuttle valve 4215MM (2).
(4) Put the PLUG - BLANKING in each disconnected line end.
WARNING:
DO NOT TOUCH THE UNIT UNTIL IT IS SUFFICIENTLY COOL TO PREVENT BURNS WHEN YOU DO THE MAINTENANCE TASK(S).
(1) Disconnect the hose connections (1). (2) If necessary, remove the nut (6), the screw (3), the washer (4) and the clamp (5).
(3) Remove shuttle valve 4215MM (2).
(4) Put the PLUG - BLANKING in each disconnected line end.
Shuttle Valve