W DOC AIRBUS | AMM A320F

Removal of the Drain Valve Control


TASK 38-32-42-000-004-A
Removal of the Drain Valve Control


1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
TASK 24-42-00-861-001-A
Energize the Ground Service Network from the External Power
TASK 38-30-00-510-001-A
Decontamination of Components of the Waste/Water and Toilet System for Shipping and/or Installation
3. Job Set-up
Subtask 38-32-42-861-052-A ** ON A/C NOT FOR ALL
A. Energize the ground service network
(Ref. AMM TASK 24-42-00-861-001).
Subtask 38-32-42-010-057-A ** ON A/C NOT FOR ALL
B. Get Access
F Shutoff Valve ** ON A/C NOT FOR ALL
   (1) Open the door of the related lavatory.
   (2) Open the sanitary cabinet door.
   (3) Close the potable-water shutoff valve (30).
4. Procedure
Subtask 38-32-42-020-053-A ** ON A/C NOT FOR ALL
A. Remove the Drain Valve Control
F Washbasin Drain Valve Control ** ON A/C NOT FOR ALL
   (1) Disengage the control rod (15) and the connecting block (11) from the drain valve control:
     (a) Remove the locknut (14), the stud (13) and the lock spring (12).
     (b) Hold the connecting block (11) and pull the lever (1) up until it is free from the connecting block (11).
     (c) Remove the plastic stop (10).
   (2) Remove the locknut (6) and the stud (7).
   (3) Remove the nut (9), the wave spring (8) and the washer (5).
   (4) Remove the plunger (2) and the gasket (3).
   (5) Discard the gasket (3).
   (6) If you will use the removed parts again, clean and disinfect them (Ref. AMM TASK 38-30-00-510-001).
[Rev.10 from 2021] 2026.04.02 06:25:59 UTC