W DOC AIRBUS | AMM A320F

Removal of the Washbasin Drain Valve


TASK 38-32-42-000-002-A
Removal of the Washbasin Drain Valve


NOTE: The removal of a drain valve in a lavatory is given. The procedure is the same for all the lavatories.
ZONE: 260
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
1
ALLEN KEY 1 INCH
No specific
1
CONTAINER 1 L (1/4 USGAL)
No specific
AR
PLUG - BLANKING
No specific
AR
SAFETY CLIP - CIRCUIT BREAKER
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
260
AFT CABIN UTILITY AREA
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 24-42-00-861-001-A
Energize the Ground Service Network from the External Power
TASK 38-30-00-510-001-A
Decontamination of Components of the Waste/Water and Toilet System for Shipping and/or Installation
F Shutoff Valve ** ON A/C NOT FOR ALL
F Shutoff Valve ** ON A/C NOT FOR ALL
F Washbasin Drain Valve ** ON A/C NOT FOR ALL
F Washbasin Drain Valve ** ON A/C NOT FOR ALL
3. Job Set-up
Subtask 38-32-42-861-051-A
A. Energize the ground service network
(Ref. AMM TASK 24-42-00-861-001).
Subtask 38-32-42-865-059-A
B. Open, safety and tag this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
2000VULAV FWD & MID-HOT WATER-A1MBF02
** ON A/C NOT FOR ALL
2000VULAV FWD-HOT WATER-A1MBF02
** ON A/C NOT FOR ALL
2001VULAVATORY AFT-HOT WATER-D2MBB02
** ON A/C NOT FOR ALL
2001VULAV AFT-HOT WATER-E9MBB03
** ON A/C NOT FOR ALL
2001VULAV AFT-HOT WATER-D2MBB02
** ON A/C NOT FOR ALL
2001VULAV AFT-HOT WATER-G9MBB03
2001VULAV AFT-HOT WATER-D/F2MBB02
** ON A/C NOT FOR ALL
2001VULAV AFT-HOT WATER9MBB03
2001VULAV AFT-HOT WATER2MBB02
** ON A/C NOT FOR ALL
2001VULAV AFT-HOT WATER-E/L9MBB03
** ON A/C NOT FOR ALL
2001VULAV AFT-HOT WATER-L9MBC04
** ON A/C NOT FOR ALL
2001VULAV AFT-HOT WATER-D/L2MBB02
** ON A/C NOT FOR ALL
2001VULAV AFT-HOT WATER-M9MBB03
Subtask 38-32-42-010-054-C ** ON A/C NOT FOR ALL
C. Get Access
F Shutoff Valve ** ON A/C NOT FOR ALL
   (1) Open the door of the related lavatory.
   (2) Open the sanitary cabinet door.
   (3) Close the potable-water shutoff valve (30).
   (4) Put the CONTAINER 1 L (1/4 USGAL) below the washbasin to collect unwanted water.
Subtask 38-32-42-010-054-H ** ON A/C NOT FOR ALL
C. Get Access
F Shutoff Valve ** ON A/C NOT FOR ALL
   (1) Open the related lavatory door.
   (2) Open the sanitary cabinet door.
   (3) For the standard lavatory:
     (a) Turn the control handle (2) to close the potable-water shutoff valve (1).
   (4) For the space flex lavatory:
     (a) Turn the control handle (4) to close the potable-water shutoff valve (3).
   (5) For the smart lavatory:
     (a) Turn the control handle (6) to close the potable-water shutoff valve (5).
   (6) Put a CONTAINER 1 L (1/4 USGAL) below the washbasin to collect the unwanted material.
4. Procedure
Subtask 38-32-42-020-051-F ** ON A/C NOT FOR ALL
A. Removal of the Drain valve in the Washbasin
F Washbasin Drain Valve ** ON A/C NOT FOR ALL
   (1) Remove the clamps (12).
   (2) Remove the hoses (13) and (11).
   (3) Put an identification mark on the valve body (5) and the washbasin for the correct installation position.
   (4) Remove the plug (1).
   (5) Remove the locknut (10) and the nut (9).
   (6) Remove the washer (8) and the spacer (7).
   (7) Remove and discard the O-ring (6).
   (8) Remove the bolt (2).
   (9) Remove the collar (3).
   (10) Remove the valve body (5) from the washbasin.
   (11) Remove and discard the packing (4).
   (12) If you will use the removed parts again, clean and disinfect them (Ref. AMM TASK 38-30-00-510-001).
Subtask 38-32-42-020-051-G ** ON A/C NOT FOR ALL
A. Removal of the Washbasin Drain Valve
F Washbasin Drain Valve ** ON A/C NOT FOR ALL
   (1) Make the match marks on the components that you disconnect/remove to record their connection/position.
NOTE: This is important for the subsequent installation procedure.
   (2) Remove the clamp (9).
   (3) Disconnect the hose (8) from the drain housing (7).
   (4) Put the PLUG-BLANKING in each disconnected line end.
   (5) Remove the stopper (10), if installed.
   (6) Remove the sieve (1) from the flange (4).
   (7) Remove and discard the packing (2).
   (8) Remove the filter assembly (3).
   (9) Hold the drain housing (7) and use an ALLEN KEY 1 INCH to remove the flange (4) from the drain housing (7).
   (10) Remove the drain housing (7) and discard the gasket (6).
   (11) If you use the removed parts again, use disinfectant to clean them (Ref. AMM TASK 38-30-00-510-001).
[Rev.10 from 2021] 2026.04.02 06:25:58 UTC