W DOC AIRBUS | AMM A320F

Installation of the Drain Valve (Air Stop Valve) in the Lavatories


TASK 38-32-41-400-001-A
Installation of the Drain Valve (Air Stop Valve) in the Lavatories


WARNING: ALWAYS USE RUBBER GLOVES WHEN YOU DO WORK:
  • ON THE TOILET WASTE SYSTEM, OR
  • ON PARTS THAT HAVE CONTAMINATION FROM THE WASTE SYSTEM.
WHEN YOU COMPLETE THE WORK PROCEDURE, CLEAN YOUR HANDS WITH SOAP AND WATER. THIS WILL PREVENT INFECTION (TOILET WASTE IS DANGEROUS FOR HEALTH).
WARNING: DO NOT DO WORK ON THE TOILET WASTE SYSTEM AND THE POTABLE WATER SYSTEM AT THE SAME TIME. THIS WILL PREVENT CONTAMINATION OF THE POTABLE WATER SYSTEM. SUCH CONTAMINATION CAN BE DANGEROUS TO HEALTH.
NOTE: The procedure for the installation of all the drain valves in the lavatories is the same.
ZONE: 260
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
1
CONTAINER 3 L(3/4 USGAL)
No specific
AR
WARNING NOTICE(S)
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
260
AFT CABIN UTILITY AREA
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 24-42-00-861-001-A
Energize the Ground Service Network from the External Power
TASK 24-42-00-862-001-A
De-energize the Ground Service Network Supplied from the External Power
TASK 38-32-00-710-002-A
Operational Test of the Waste/Water Drain System
F Drain Valve ** ON A/C NOT FOR ALL
F Drain Valve ** ON A/C NOT FOR ALL
3. Job Set-up
Subtask 38-32-41-860-050-A
A. Aircraft Maintenance Configuration
F Drain Valve ** ON A/C NOT FOR ALL
F Drain Valve ** ON A/C NOT FOR ALL
   (1) Make sure that the ground service network is energized
(Ref. AMM TASK 24-42-00-861-001).
   (2) Make sure that the door of the related lavatory is open.
   (3) Make sure that the access door of the related potable-water shutoff valve (8) is open.
   (4) Make sure that the related potable-water shutoff valve (8) is closed.
   (5) Make sure that the WARNING NOTICE(S) is(are) in position to tell persons not to open the potable-water shutoff valve (8).
Subtask 38-32-41-865-053-A
B. Make sure that this(these) circuit breaker(s) is(are) open, safetied and tagged:
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
2000VULAV FWD & MID-HOT WATER-A1MBF02
** ON A/C NOT FOR ALL
2000VULAV FWD-HOT WATER-A1MBF02
** ON A/C NOT FOR ALL
2001VULAVATORY AFT-HOT WATER-D2MBB02
** ON A/C NOT FOR ALL
2001VULAV AFT-HOT WATER-E9MBB03
** ON A/C NOT FOR ALL
2001VULAV AFT-HOT WATER-D2MBB02
** ON A/C NOT FOR ALL
2001VULAV AFT-HOT WATER-G9MBB03
2001VULAV AFT-HOT WATER-D/F2MBB02
** ON A/C NOT FOR ALL
2001VULAV AFT-HOT WATER9MBB03
2001VULAV AFT-HOT WATER2MBB02
** ON A/C NOT FOR ALL
2001VULAV AFT-HOT WATER-E/L9MBB03
** ON A/C NOT FOR ALL
2001VULAV AFT-HOT WATER-L9MBC04
** ON A/C NOT FOR ALL
2001VULAV AFT-HOT WATER-D/L2MBB02
** ON A/C NOT FOR ALL
2001VULAV AFT-HOT WATER-M9MBB03
4. Procedure
Subtask 38-32-41-420-051-B ** ON A/C NOT FOR ALL
A. Installation of the Drain Valve 4251MM
   (1) Clean the component interfaces and the adjacent area.
   (2) Do an inspection of the component interfaces and the adjacent area.
   (3) Make sure that the parts retained from the removed component are clean and in the correct condition.
   (4) Put the drain valve (5) in position.
   (5) Install the washers (4) and the screws (3).
   (6) Remove the blanking plugs and install the hoses (2) and (6).
   (7) Install the clamps (1).
   (8) Open the shut off valve (7).
   (9) Close the access panel to the potable water shut off valve.
Subtask 38-32-41-420-051-D ** ON A/C NOT FOR ALL
A. Installation of the Drain Valve 4251MM
   (1) Clean the component interfaces and the adjacent area.
   (2) Do an inspection of the component interfaces and the adjacent area.
   (3) Make sure that the parts retained from the removed component are clean and in the correct condition.
   (4) Put drain valve (5) in its installation position.
   (5) Install the washers (4) and the screws (3).
   (6) Remove the blanking plugs and connect the hoses (6) and (2).
   (7) Install the clamps (7) and (1).
Subtask 38-32-41-420-051-R ** ON A/C NOT FOR ALL
A. Installation of the Drain Valve
   (1) Make sure that the CONTAINER 3 L(3/4 USGAL) is below the washbasin to collect the water.
   (2) Clean the component interfaces and the adjacent area.
   (3) Do an inspection of the component interfaces and the adjacent area.
   (4) Make sure that the parts retained from the removed component are clean and in the correct condition.
   (5) Put the drain valve (6) in its installation position.
   (6) Install the washers (2), the screws (1) and the nuts (3).
   (7) Tighten the nuts (3).
   (8) Remove the PLUG-BLANKING from each disconnected line end.
   (9) Connect the hoses (5) and (7) to the drain valve (6).
   (10) Put the clamps (4) on the hoses (5) and (7).
   (11) Tighten the screws of the clamps (4).
   (12) Remove the WARNING NOTICE(S) related to the potable-water shutoff valve (8).
   (13) Turn the control handle to open the related potable-water shutoff valve (8).
Subtask 38-32-41-865-054-A
B. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
2000VULAV FWD & MID-HOT WATER-A1MBF02
** ON A/C NOT FOR ALL
2000VULAV FWD-HOT WATER-A1MBF02
** ON A/C NOT FOR ALL
2001VULAVATORY AFT-HOT WATER-D2MBB02
** ON A/C NOT FOR ALL
2001VULAV AFT-HOT WATER-E9MBB03
** ON A/C NOT FOR ALL
2001VULAV AFT-HOT WATER-D2MBB02
** ON A/C NOT FOR ALL
2001VULAV AFT-HOT WATER-G9MBB03
2001VULAV AFT-HOT WATER-D/F2MBB02
** ON A/C NOT FOR ALL
2001VULAV AFT-HOT WATER9MBB03
2001VULAV AFT-HOT WATER2MBB02
** ON A/C NOT FOR ALL
2001VULAV AFT-HOT WATER-E/L9MBB03
** ON A/C NOT FOR ALL
2001VULAV AFT-HOT WATER-L9MBC04
** ON A/C NOT FOR ALL
2001VULAV AFT-HOT WATER-D/L2MBB02
** ON A/C NOT FOR ALL
2001VULAV AFT-HOT WATER-M9MBB03
Subtask 38-32-41-710-050-A
C. Do the operational test of the waste/water drain system (Ref. AMM TASK 38-32-00-710-002).
5. Close-up
Subtask 38-32-41-410-052-A
A. Close Access
F Drain Valve ** ON A/C NOT FOR ALL
F Drain Valve ** ON A/C NOT FOR ALL
   (1) Remove the CONTAINER 3 L(3/4 USGAL).
   (2) Make sure that the work area is clean and clear of tools and other items.
   (3) Close the access door of the related potable-water shutoff valve (8).
   (4) Close the related lavatory door.
Subtask 38-32-41-862-051-A
B. De-energize the ground service network
(Ref. AMM TASK 24-42-00-862-001).
[Rev.10 from 2021] 2026.04.02 06:25:58 UTC