Removal of the Waste Drain-Line Valve
TASK 38-31-72-000-001-A
Removal of the Waste Drain-Line Valve
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 38-31-72-861-050-A Subtask 38-31-72-680-050-A Subtask 38-31-72-865-063-A
Subtask 38-31-72-020-050-A
[Rev.10 from 2021]
2026.04.01 01:21:01 UTC
Removal of the Waste Drain-Line Valve
WARNING:
DO NOT DO WORK ON THE TOILET WASTE SYSTEM AND THE POTABLE WATER SYSTEM AT THE SAME TIME. THIS WILL PREVENT CONTAMINATION OF THE POTABLE WATER SYSTEM. SUCH CONTAMINATION CAN BE DANGEROUS TO HEALTH.
WARNING:
ALWAYS USE RUBBER GLOVES WHEN YOU DO WORK:
- ON THE TOILET WASTE SYSTEM, OR
- ON PARTS THAT HAVE CONTAMINATION FROM THE WASTE SYSTEM.
WARNING:
WHEN YOU REMOVE A COMPONENT OF THE TOILET WASTE SYSTEM, ALWAYS DISINFECT THE PART BEFORE YOU PUT IT IN A PLASTIC BAG, THEN SEAL THE BAG.
DO NOT PUT DOCUMENTS INTO THE PLASTIC BAG. SEAL THE BAG FIRST,THEN ATTACH THE DOCUMENTS TO IT.
THIS WILL PREVENT INFECTION OR ILLNESS. CONTAMINATION FROM THE WASTE CAN BE DANGEROUS TO HEALTH.
FIN: 3345MM
1. Reason for the JobSelf explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | ACCESS PLATFORM 2M (6 FT) |
| No specific | AR | SAFETY CLIP - CIRCUIT BREAKER |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 172AR |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-42-00-861-001-A | Energize the Ground Service Network from the External Power |
| TASK 38-30-00-510-001-A | Decontamination of Components of the Waste/Water and Toilet System for Shipping and/or Installation |
| TASK 38-31-00-680-001-A | Draining of the Toilet System |
Subtask 38-31-72-861-050-A Subtask 38-31-72-680-050-A Subtask 38-31-72-865-063-A
C. Open, safety and tag this(these) circuit breaker(s):
Subtask 38-31-72-010-050-A | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 2001VU | VACU TOIL SYS-VACUUM-SYS | 35MG | A06 |
| ** ON A/C NOT FOR ALL | |||
| 2001VU | VACU TOIL SYS-VACUUM-GEN | 33MG | A08 |
| ** ON A/C NOT FOR ALL | |||
| 2001VU | VACU TOIL SYS-LAV PWR-E | 34MG | A04 |
| ** ON A/C NOT FOR ALL | |||
| 2001VU | VACU TOIL SYS-LAV PWR-D | 39MG | A03 |
| ** ON A/C ALL | |||
| 2001VU | VACU TOIL SYS-LAV PWR-A | 32MG | A01 |
| ** ON A/C NOT FOR ALL | |||
| 2001VU | VACU TOIL SYS-VACU-SYS | 35MG | A06 |
| ** ON A/C NOT FOR ALL | |||
| 2001VU | VACU TOIL SYS-VACU-GEN | 33MG | A08 |
| ** ON A/C NOT FOR ALL | |||
| 2001VU | VACU TOIL SYS-LAV PWR-G | 34MG | A04 |
| 2001VU | VACU TOIL SYS-LAV PWR-F | 39MG | A03 |
| 2001VU | VACU TOIL SYS-LAV PWR-D | 45MG | A02 |
| ** ON A/C NOT FOR ALL | |||
| 2001VU | VACU TOIL SYS-LAV PWR-L | 45MG | A02 |
| ** ON A/C NOT FOR ALL | |||
| 2001VU | VACU TOIL SYS-LAV PWR-L | 23MG | A05 |
| ** ON A/C NOT FOR ALL | |||
| 2001VU | VACU TOIL SYS-LAV PWR-M | 34MG | A04 |
D. Get Access
(1) Put the ACCESS PLATFORM 2M (6 FT) in position at the waste service panel 172AR.
(2) Open the waste service panel 172AR.
(3) Open the waste outlet cover.
4. Procedure(1) Put the ACCESS PLATFORM 2M (6 FT) in position at the waste service panel 172AR.
(2) Open the waste service panel 172AR.
(3) Open the waste outlet cover.
Subtask 38-31-72-020-050-A
A. Removal of the Waste Drain-Line Valve 3345MM
(2) Remove the waste drain-line valve 3345MM (1).
(3) Remove and discard the packing (3).
(4) If you use removed parts again, clean and disinfect them (Ref. AMM TASK 38-30-00-510-001).
WARNING:
ALWAYS WEAR RUBBER GLOVES, GOGGLES AND PROTECTIVE CLOTHES WHEN YOU DO THIS TASK.
(1) Remove the screws (2). (2) Remove the waste drain-line valve 3345MM (1).
(3) Remove and discard the packing (3).
(4) If you use removed parts again, clean and disinfect them (Ref. AMM TASK 38-30-00-510-001).
Waste Drain-line valve