Installation of the Waste Drain Valve
TASK 38-31-71-400-001-A
Installation of the Waste Drain Valve
Self explanatory
2. Job Set-up Information
A. Work Zones and Access Panels
B. Expendable Parts
C. Referenced Information
3. Job Set-up
Subtask 38-31-71-860-050-A
Subtask 38-31-71-420-050-A
Subtask 38-31-71-410-050-C
[Rev.10 from 2021]
2026.04.01 01:21:00 UTC
Installation of the Waste Drain Valve
WARNING:
DO NOT DO WORK ON THE TOILET WASTE SYSTEM AND THE POTABLE WATER SYSTEM AT THE SAME TIME. THIS WILL PREVENT CONTAMINATION OF THE POTABLE WATER SYSTEM. SUCH CONTAMINATION CAN BE DANGEROUS TO HEALTH.
WARNING:
ALWAYS USE RUBBER GLOVES WHEN YOU DO WORK:
- ON THE TOILET WASTE SYSTEM, OR
- ON PARTS THAT HAVE CONTAMINATION FROM THE WASTE SYSTEM.
FIN: 3340MM
1. Reason for the JobSelf explanatory
2. Job Set-up Information
A. Work Zones and Access Panels
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 162DW |
| FIG.ITEM | DESIGNATION | IPC-CSN |
|---|---|---|
| 4 | PACKING | AIPC 38-31-04-32-070 |
| 4 | PACKING | AIPC 38-31-84-40-110 |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 12-16-38-613-001-A | Servicing of the Toilet System |
| TASK 24-41-00-861-002-A | Energize the Aircraft Electrical Circuits from the External Power |
| TASK 24-41-00-861-002-A-01 | Energize the Aircraft Electrical Circuits from the APU |
| TASK 24-41-00-861-002-A-02 | Energize the Aircraft Electrical Circuits from Engine 1(2) |
| TASK 24-41-00-862-002-A | De-energize the Aircraft Electrical Circuits Supplied from the External Power |
| TASK 24-41-00-862-002-A-01 | De-energize the Aircraft Electrical Circuits Supplied from the APU |
| TASK 24-41-00-862-002-A-02 | De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2) |
| TASK 25-55-12-400-001-A | Installation of the Aft Cargo-Compartment Partition at FR65 |
| TASK 38-31-00-680-001-A | Draining of the Toilet System |
| TASK 38-31-74-400-001-A | Installation of the Waste Tank Drain Line |
| TASK 52-30-00-860-002-A | Close the FWD or Aft Cargo-Compartment Door with the Yellow Electric Pump |
Subtask 38-31-71-860-050-A
A. Aircraft Maintenance Configuration
(1) Make sure that the aircraft electrical circuits are energized (Ref. AMM TASK 24-41-00-861-002).
(2) Make sure that the toilet system is drained (Ref. AMM TASK 38-31-00-680-001).
Subtask 38-31-71-865-063-A (1) Make sure that the aircraft electrical circuits are energized (Ref. AMM TASK 24-41-00-861-002).
(2) Make sure that the toilet system is drained (Ref. AMM TASK 38-31-00-680-001).
B. Make sure that this(these) circuit breaker(s) is(are) open, safetied and tagged:
4. Procedure| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 2001VU | VACU TOIL SYS-VACUUM-SYS | 35MG | A06 |
| ** ON A/C NOT FOR ALL | |||
| 2001VU | VACU TOIL SYS-VACUUM-GEN | 33MG | A08 |
| ** ON A/C NOT FOR ALL | |||
| 2001VU | VACU TOIL SYS-LAV PWR-E | 34MG | A04 |
| ** ON A/C NOT FOR ALL | |||
| 2001VU | VACU TOIL SYS-LAV PWR-D | 39MG | A03 |
| ** ON A/C ALL | |||
| 2001VU | VACU TOIL SYS-LAV PWR-A | 32MG | A01 |
| ** ON A/C NOT FOR ALL | |||
| 2001VU | VACU TOIL SYS-VACU-SYS | 35MG | A06 |
| ** ON A/C NOT FOR ALL | |||
| 2001VU | VACU TOIL SYS-VACU-GEN | 33MG | A08 |
| ** ON A/C NOT FOR ALL | |||
| 2001VU | VACU TOIL SYS-LAV PWR-G | 34MG | A04 |
| 2001VU | VACU TOIL SYS-LAV PWR-F | 39MG | A03 |
| 2001VU | VACU TOIL SYS-LAV PWR-D | 45MG | A02 |
| ** ON A/C NOT FOR ALL | |||
| 2001VU | VACU TOIL SYS-LAV PWR-L | 45MG | A02 |
| ** ON A/C NOT FOR ALL | |||
| 2001VU | VACU TOIL SYS-LAV PWR-L | 23MG | A05 |
| ** ON A/C NOT FOR ALL | |||
| 2001VU | VACU TOIL SYS-LAV PWR-M | 34MG | A04 |
Subtask 38-31-71-420-050-A
A. Installation of the Waste Drain Valve 3340MM
(1) Remove the blanking plugs from the line ends.
(2) Install a new AIPC 38-31-04-32-070 PACKING (4) or AIPC 38-31-84-40-110 PACKING (4).
(3) Put the waste drain valve 3340 MM (9) in position.
(4) Install the bolts (6), the washers (7) and the nuts (8).
(5) Put the control lever (5) in position.
(6) Install the bolt (1).
(7) Install the washer (2) and the nut (3).
(8) Install the waste drain line (10) (Ref. AMM TASK 38-31-74-400-001).
Subtask 38-31-71-865-065-A (1) Remove the blanking plugs from the line ends.
(2) Install a new AIPC 38-31-04-32-070 PACKING (4) or AIPC 38-31-84-40-110 PACKING (4).
(3) Put the waste drain valve 3340 MM (9) in position.
(4) Install the bolts (6), the washers (7) and the nuts (8).
(5) Put the control lever (5) in position.
(6) Install the bolt (1).
(7) Install the washer (2) and the nut (3).
(8) Install the waste drain line (10) (Ref. AMM TASK 38-31-74-400-001).
B. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
Subtask 38-31-71-790-051-A | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 2001VU | VACU TOIL SYS-VACUUM-SYS | 35MG | A06 |
| ** ON A/C NOT FOR ALL | |||
| 2001VU | VACU TOIL SYS-VACUUM-GEN | 33MG | A08 |
| ** ON A/C NOT FOR ALL | |||
| 2001VU | VACU TOIL SYS-LAV PWR-E | 34MG | A04 |
| ** ON A/C NOT FOR ALL | |||
| 2001VU | VACU TOIL SYS-LAV PWR-D | 39MG | A03 |
| ** ON A/C ALL | |||
| 2001VU | VACU TOIL SYS-LAV PWR-A | 32MG | A01 |
| ** ON A/C NOT FOR ALL | |||
| 2001VU | VACU TOIL SYS-VACU-SYS | 35MG | A06 |
| ** ON A/C NOT FOR ALL | |||
| 2001VU | VACU TOIL SYS-VACU-GEN | 33MG | A08 |
| ** ON A/C NOT FOR ALL | |||
| 2001VU | VACU TOIL SYS-LAV PWR-G | 34MG | A04 |
| 2001VU | VACU TOIL SYS-LAV PWR-F | 39MG | A03 |
| 2001VU | VACU TOIL SYS-LAV PWR-D | 45MG | A02 |
| ** ON A/C NOT FOR ALL | |||
| 2001VU | VACU TOIL SYS-LAV PWR-L | 45MG | A02 |
| ** ON A/C NOT FOR ALL | |||
| 2001VU | VACU TOIL SYS-LAV PWR-L | 23MG | A05 |
| ** ON A/C NOT FOR ALL | |||
| 2001VU | VACU TOIL SYS-LAV PWR-M | 34MG | A04 |
C. Do this Leak Test
(1) Make sure that the drain cap 3345MM is close.
(2) Put the drain lever 3341MM to the drain position.
(3) Fill the waste tank with approximately 10 l of water.
(4) Examine the waste drain valve 3340MM and the valve attachments for leaks.
Subtask 38-31-71-613-050-A 5. Close-up(1) Make sure that the drain cap 3345MM is close.
(2) Put the drain lever 3341MM to the drain position.
(3) Fill the waste tank with approximately 10 l of water.
(4) Examine the waste drain valve 3340MM and the valve attachments for leaks.
NOTE: Leaks are not permitted.
(5) Drain the waste holding tank (Ref. AMM TASK 38-31-00-680-001). Subtask 38-31-71-410-050-C
A. Close Access
(1) Install the insulation around the waste drain valve.
(2) Make sure that the work area is clean and clear of tools and other items.
(3) Install access panel 162DW (Ref. AMM TASK 25-55-12-400-001).
(4) Close the aft cargo compartment door (Ref. AMM TASK 52-30-00-860-002).
(5) Remove the access platform(s).
Subtask 38-31-71-862-050-A (1) Install the insulation around the waste drain valve.
(2) Make sure that the work area is clean and clear of tools and other items.
(3) Install access panel 162DW (Ref. AMM TASK 25-55-12-400-001).
(4) Close the aft cargo compartment door (Ref. AMM TASK 52-30-00-860-002).
(5) Remove the access platform(s).
Waste Drain Valve