W DOC AIRBUS | AMM A320F

Installation of the Altitude Pressure Switch


TASK 38-31-69-400-001-A
Installation of the Altitude Pressure Switch


FIN: 43MG ** ON A/C NOT FOR ALL
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
312AR
 B. Referenced Information
REFERENCE
DESIGNATION
TASK 24-42-00-861-001-A
Energize the Ground Service Network from the External Power
TASK 24-42-00-862-001-A
De-energize the Ground Service Network Supplied from the External Power
TASK 38-31-00-710-002-A
Operational Test of the Vacuum Toilet System
3. Job Set-up
Subtask 38-31-69-860-050-A ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
   (1) Make sure that the ground service network is energized from the external power (Ref. AMM TASK 24-42-00-861-001).
Subtask 38-31-69-865-059-A ** ON A/C NOT FOR ALL
B. Make sure that this(these) circuit breaker(s) is(are) open, safetied and tagged:
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
2001VUVACU TOIL SYS-VACUUM-SYS35MGA06
** ON A/C NOT FOR ALL
2001VUVACU TOIL SYS-VACUUM-GEN33MGA08
2001VUVACU TOIL SYS-LAV PWR-E34MGA04
2001VUVACU TOIL SYS-LAV PWR-D39MGA03
2001VUVACU TOIL SYS-LAV PWR-A32MGA01
** ON A/C NOT FOR ALL
2001VUVACU TOIL SYS-VACU-SYS35MGA06
2001VUVACU TOIL SYS-LAV PWR-L45MGA02
4. Procedure
Subtask 38-31-69-420-050-A ** ON A/C NOT FOR ALL
A. Installation of the Altitude Pressure Switch 43MG
   (1) Clean the component interfaces and the adjacent area.
   (2) Do an inspection of the component interfaces and the adjacent area.
   (3) Install the altitude pressure switch (1).
   (4) Install the washers (3) and the bolts (4).
   (5) Make sure that all the electrical connections are clean and in the correct condition.
   (6) Connect the electrical connector (5).
Subtask 38-31-69-865-060-A ** ON A/C NOT FOR ALL
B. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
2001VUVACU TOIL SYS-VACUUM-SYS35MGA06
** ON A/C NOT FOR ALL
2001VUVACU TOIL SYS-VACUUM-GEN33MGA08
2001VUVACU TOIL SYS-LAV PWR-E34MGA04
2001VUVACU TOIL SYS-LAV PWR-D39MGA03
2001VUVACU TOIL SYS-LAV PWR-A32MGA01
** ON A/C NOT FOR ALL
2001VUVACU TOIL SYS-VACU-SYS35MGA06
2001VUVACU TOIL SYS-LAV PWR-L45MGA02
Subtask 38-31-69-710-050-A ** ON A/C NOT FOR ALL
C. Do the operational test of the toilet system (Ref. AMM TASK 38-31-00-710-002).
5. Close-up
Subtask 38-31-69-410-050-A ** ON A/C NOT FOR ALL
A. Close Access
   (1) Make sure that the work area is clean and clear of tools and other items.
   (2) Close the access door 312AR.
   (3) Remove the access platform(s).
Subtask 38-31-69-862-050-A ** ON A/C NOT FOR ALL
B. De-energize the ground service network
(Ref. AMM TASK 24-42-00-862-001).