Installation of the Liquid Level Transmitter


TASK 38-31-62-400-001-A
Installation of the Liquid Level Transmitter


WARNING: DO NOT DO WORK ON THE TOILET WASTE SYSTEM AND THE POTABLE WATER SYSTEM AT THE SAME TIME. THIS WILL PREVENT CONTAMINATION OF THE POTABLE WATER SYSTEM. SUCH CONTAMINATION CAN BE DANGEROUS TO HEALTH.
WARNING: ALWAYS USE RUBBER GLOVES WHEN YOU DO WORK:
  • ON THE TOILET WASTE SYSTEM, OR
  • ON PARTS THAT HAVE CONTAMINATION FROM THE WASTE SYSTEM.
WHEN YOU COMPLETE THE WORK PROCEDURE, CLEAN YOUR HANDS WITH SOAP AND WATER. THIS WILL PREVENT INFECTION (TOILET WASTE IS DANGEROUS FOR HEALTH).
FIN: 40MG
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
Torque wrench: range to between 0.11 and 0.09 m.daN (9.73 and 7.96 lbf.in ) T
No specific
Torque wrench: range to between 0.16 and 0.14 m.daN (14.16 and 12.39 lbf.in ) T
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
162DW
 C. Expendable Parts
FIG.ITEM
DESIGNATION
IPC-CSN
2
PACKING
AIPC 38-31-04-34-050
2
PACKING
AIPC 38-31-84-44-140
 D. Referenced Information
REFERENCE
DESIGNATION
TASK 12-16-38-613-001-A
Servicing of the Toilet System
TASK 20-23-38-400-003-A
Installation of the Tube Assembly of the Potable Water and the associated Air Supply System
TASK 24-42-00-861-001-A
Energize the Ground Service Network from the External Power
TASK 25-55-12-400-001-A
Installation of the Aft Cargo-Compartment Partition at FR65
TASK 38-31-00-680-001-A
Draining of the Toilet System
TASK 38-31-00-720-002-A
Functional Test of the Liquid Level Sensor and Transmitter
TASK 52-30-00-860-002-A
Close the FWD or Aft Cargo-Compartment Door with the Yellow Electric Pump
F Liquid Level Transmitter 40MG ** ON A/C NOT FOR ALL
F Liquid Level Transmitter 40MG ** ON A/C NOT FOR ALL
3. Job Set-up
Subtask 38-31-62-860-050-A
A. Aircraft Maintenance Configuration
   (1) Make sure that the ground service network is energized from the external power (Ref. AMM TASK 24-42-00-861-001).
   (2) Make sure that the toilet system is drained (Ref. AMM TASK 38-31-00-680-001).
Subtask 38-31-62-865-064-A
B. Make sure that this(these) circuit breaker(s) is(are) open, safetied and tagged:
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
2001VUVACU TOIL SYS-VACUUM-SYS35MGA06
** ON A/C NOT FOR ALL
2001VUVACU TOIL SYS-VACUUM-GEN33MGA08
** ON A/C NOT FOR ALL
2001VUVACU TOIL SYS-LAV PWR-E34MGA04
** ON A/C NOT FOR ALL
2001VUVACU TOIL SYS-LAV PWR-D39MGA03
** ON A/C ALL
2001VUVACU TOIL SYS-LAV PWR-A32MGA01
** ON A/C NOT FOR ALL
2001VUVACU TOIL SYS-VACU-SYS35MGA06
** ON A/C NOT FOR ALL
2001VUVACU TOIL SYS-VACU-GEN33MGA08
** ON A/C NOT FOR ALL
2001VUVACU TOIL SYS-LAV PWR-G34MGA04
2001VUVACU TOIL SYS-LAV PWR-F39MGA03
2001VUVACU TOIL SYS-LAV PWR-D45MGA02
** ON A/C NOT FOR ALL
2001VUVACU TOIL SYS-LAV PWR-L45MGA02
** ON A/C NOT FOR ALL
2001VUVACU TOIL SYS-LAV PWR-L23MGA05
** ON A/C NOT FOR ALL
2001VUVACU TOIL SYS-LAV PWR-M34MGA04
4. Procedure
Subtask 38-31-62-420-050-A ** ON A/C NOT FOR ALL Subtask 38-31-62-420-050-B ** ON A/C NOT FOR ALL Subtask 38-31-62-865-065-A
B. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
2001VUVACU TOIL SYS-VACUUM-SYS35MGA06
** ON A/C NOT FOR ALL
2001VUVACU TOIL SYS-VACUUM-GEN33MGA08
** ON A/C NOT FOR ALL
2001VUVACU TOIL SYS-LAV PWR-E34MGA04
** ON A/C NOT FOR ALL
2001VUVACU TOIL SYS-LAV PWR-D39MGA03
** ON A/C ALL
2001VUVACU TOIL SYS-LAV PWR-A32MGA01
** ON A/C NOT FOR ALL
2001VUVACU TOIL SYS-VACU-SYS35MGA06
** ON A/C NOT FOR ALL
2001VUVACU TOIL SYS-VACU-GEN33MGA08
** ON A/C NOT FOR ALL
2001VUVACU TOIL SYS-LAV PWR-G34MGA04
2001VUVACU TOIL SYS-LAV PWR-F39MGA03
2001VUVACU TOIL SYS-LAV PWR-D45MGA02
** ON A/C NOT FOR ALL
2001VUVACU TOIL SYS-LAV PWR-L45MGA02
** ON A/C NOT FOR ALL
2001VUVACU TOIL SYS-LAV PWR-L23MGA05
** ON A/C NOT FOR ALL
2001VUVACU TOIL SYS-LAV PWR-M34MGA04
Subtask 38-31-62-720-050-A
C. Functional Test
   (1) Do the functional test of the liquid level sensor and the transmitter (Ref. AMM TASK 38-31-00-720-002).
     (a) Make sure that there is no water leak at the liquid-level transmitter flange during this test.
Subtask 38-31-62-790-050-A
DELETED
5. Close-up
Subtask 38-31-62-680-051-A
A. Draining of the Waste Holding Tank
   (1) Drain the waste holding tank (Ref. AMM TASK 38-31-00-680-001).
Subtask 38-31-62-613-050-A
B. Servicing of the Waste Holding Tank
   (1) Service the waste holding tank (Ref. AMM TASK 12-16-38-613-001).
Subtask 38-31-62-410-050-C
C. Close Access
   (1) Install the insulation around the liquid level transmitter.
   (2) Remove the container.
   (3) Make sure that the work area is clean and clear of tools and other items.
   (4) Install access panel 162DW (Ref. AMM TASK 25-55-12-400-001).
   (5) Remove the ground support and maintenance equipment, the special and standard tools and all other items.
   (6) Close the AFT cargo compartment door (Ref. AMM TASK 52-30-00-860-002).