Installation of the Waste Holding Tank


TASK 38-31-61-400-001-A
Installation of the Waste Holding Tank


WARNING: DO NOT DO WORK ON THE TOILET WASTE SYSTEM AND THE POTABLE WATER SYSTEM AT THE SAME TIME. THIS WILL PREVENT CONTAMINATION OF THE POTABLE WATER SYSTEM. SUCH CONTAMINATION CAN BE DANGEROUS TO HEALTH.
WARNING: ALWAYS USE RUBBER GLOVES WHEN YOU DO WORK:
  • ON THE TOILET WASTE SYSTEM, OR
  • ON PARTS THAT HAVE CONTAMINATION FROM THE WASTE SYSTEM.
WHEN YOU COMPLETE THE WORK PROCEDURE, CLEAN YOUR HANDS WITH SOAP AND WATER. THIS WILL PREVENT INFECTION (TOILET WASTE IS DANGEROUS FOR HEALTH).
WARNING: BE CAREFUL WHEN YOU USE CONSUMABLE MATERIALS. OBEY THE MATERIAL MANUFACTURER'S INSTRUCTIONS AND YOUR LOCAL REGULATIONS.
WARNING: BE CAREFUL WHEN YOU REMOVE OR INSTALL THIS EQUIPMENT. THIS EQUIPMENT IS HEAVY (MORE THAN 12 KG (26.5 lb)) AND CAN CAUSE INJURY AND/OR DAMAGE.
ZONE: 160
ZONE: 170
FIN: 3300MM
1. Reason for the Job
NOTE: The installation of only one quick-coupler clamp is given. The installation is applicable to all the clamps of this type.
NOTE: More than one person is necessary for this procedure.
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
1
ACCESS PLATFORM 2M (6 FT)
No specific
Torque wrench: range to between 10.16 and 9.04 m.N (89.91 and 80.00 lbf.in ) T
 B. Consumable Materials
REFERENCE
DESIGNATION
(Material No.03FAB1)
Mineral Oil base Grease-- Vaseline or Petrolatum -
(Material No.03PEB1)
Lubricant-Rubber seal Glycerin -
 C. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
160
BULK CARGO COMPARTMENT AFT BULKHEAD OF AFT CARGO COMPARTMENT TO AFT BULKHEAD OF BULK CARGO COMPARTMENT
170
AFT CAB U/FLOOR COMPT AFT BHD OF BULK
161DW, 162DW
 D. Expendable Parts
FIG.ITEM
DESIGNATION
IPC-CSN
13
PACKING
AIPC 38-31-04-26-100
28
PACKING
AIPC 38-31-04-26-100
13
PACKING
AIPC 38-31-04-27-070
28
PACKING
AIPC 38-31-04-27-070
28
PACKING
AIPC 38-31-84-32-010
13
PACKING
AIPC 38-31-84-32-013
28
PACKING
AIPC 38-31-84-32-013
13
PACKING
AIPC 38-31-84-32-300
28
PACKING
AIPC 38-31-84-32-300
28
PACKING
AIPC 38-31-84-32-305
 E. Referenced Information
REFERENCE
DESIGNATION
TASK 20-28-00-912-802-A
Electrical Bonding - General Maintenance Procedure
TASK 20-28-00-912-803-A
Bonding Surface Preparation
TASK 24-42-00-861-001-A
Energize the Ground Service Network from the External Power
TASK 24-42-00-862-001-A
De-energize the Ground Service Network Supplied from the External Power
TASK 25-55-12-000-001-A
Removal of the Aft Cargo-Compartment Partition at FR65
TASK 25-55-12-400-001-A
Installation of the Aft Cargo-Compartment Partition at FR65
TASK 38-31-00-680-001-A
Draining of the Toilet System
TASK 38-31-00-710-009-A
Operational Test of the Toilet Unit
TASK 38-31-00-790-002-A
Leak Test of the Vacuum Toilet System (VTS)
TASK 38-31-62-400-001-A
Installation of the Liquid Level Transmitter
TASK 38-31-63-400-001-A
Installation of the Liquid Level Sensor
TASK 38-31-67-400-001-A
Installation of the Water Separator
TASK 38-31-74-400-001-A
Installation of the Waste Tank Drain Line
TASK 52-30-00-860-001-A
Open the FWD or Aft Cargo-Compartment Door with the Yellow Electric Pump
TASK 52-30-00-860-002-A
Close the FWD or Aft Cargo-Compartment Door with the Yellow Electric Pump
TASK 52-30-00-860-003-A
Open the FWD or Aft Cargo-Compartment Door with the Hand Pump
TASK 52-30-00-860-004-A
Close the FWD or Aft Cargo-Compartment Door with the Hand Pump
TASK 53-43-11-000-001-A
Removal of the Support Strut
TASK 53-43-11-400-001-A
Installation of the Support Strut
F Waste Holding Tank 3300MM ** ON A/C NOT FOR ALL
F Waste Holding Tank 3300MM ** ON A/C NOT FOR ALL
F Waste Holding Tank 3300MM ** ON A/C NOT FOR ALL
3. Job Set-up
Subtask 38-31-61-860-052-A
A. Aircraft Maintenance Configuration
   (1) Make sure that the ground service network is energized
(Ref. AMM TASK 24-42-00-861-001).
   (2) Make sure that the waste holding tank is drained (Ref. AMM TASK 38-31-00-680-001).
   (3) Make sure that aft cargo-compartment door 826 is open (Ref. AMM TASK 52-30-00-860-001) or (Ref. AMM TASK 52-30-00-860-003).
   (4) Make sure that the ACCESS PLATFORM 2M (6 FT) is in position at aft cargo-compartment door 826.
   (5) Make sure that cargo-compartment light switch 8LU is set to ON.
   (6) Make sure that partitions 161DW and 162DW are removed (Ref. AMM TASK 25-55-12-000-001).
   (7) Make sure that the center support strut is removed at FR65 (Ref. AMM TASK 53-43-11-000-001).
   (8) Make sure that the insulation around the waste holding tank is removed.
Subtask 38-31-61-860-051-A ** ON A/C NOT FOR ALL
B. Installation of the Removed Components
   (1) If removed, install level sensor 41MG onto waste holding tank 3300MM (Ref. AMM TASK 38-31-63-400-001).
Subtask 38-31-61-860-051-C ** ON A/C NOT FOR ALL
B. Installation of the Removed Components
F Waste Holding Tank 3300MM ** ON A/C NOT FOR ALL
F Waste Holding Tank 3300MM ** ON A/C NOT FOR ALL
   (1) If removed, install level sensor 41MG (10) onto waste holding tank 3300MM (Ref. AMM TASK 38-31-63-400-001).
Subtask 38-31-61-865-068-A
C. Make sure that this(these) circuit breaker(s) is(are) open, safetied and tagged:
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
2001VUVACU TOIL SYS-VACUUM-SYS35MGA06
** ON A/C NOT FOR ALL
2001VUVACU TOIL SYS-VACUUM-GEN33MGA08
** ON A/C NOT FOR ALL
2001VUVACU TOIL SYS-LAV PWR-E34MGA04
** ON A/C NOT FOR ALL
2001VUVACU TOIL SYS-LAV PWR-D39MGA03
** ON A/C ALL
2001VUVACU TOIL SYS-LAV PWR-A32MGA01
** ON A/C NOT FOR ALL
2001VUVACU TOIL SYS-VACU-SYS35MGA06
** ON A/C NOT FOR ALL
2001VUVACU TOIL SYS-VACU-GEN33MGA08
** ON A/C NOT FOR ALL
2001VUVACU TOIL SYS-LAV PWR-G34MGA04
2001VUVACU TOIL SYS-LAV PWR-F39MGA03
2001VUVACU TOIL SYS-LAV PWR-D45MGA02
** ON A/C NOT FOR ALL
2001VUVACU TOIL SYS-LAV PWR-L45MGA02
** ON A/C NOT FOR ALL
2001VUVACU TOIL SYS-LAV PWR-L23MGA05
** ON A/C NOT FOR ALL
2001VUVACU TOIL SYS-LAV PWR-M34MGA04
4. Procedure
Subtask 38-31-61-420-052-A ** ON A/C NOT FOR ALL
A. Installation of Waste Holding Tank 3300MM
F Clamp Installation Requirements ** ON A/C NOT FOR ALL
   (1) Clean the component interfaces and the adjacent area.
   (2) Do an inspection of the component interfaces and the adjacent area.
   (3) Prepare the surface of the bonding point(s)
(Ref. AMM TASK 20-28-00-912-803).
   (4) Remove the PLUG-BLANKING from each disconnected line end.
   (5) Put waste holding tank 3300MM (1) in its correct installation position.
   (6) Install the quick coupler clamps (2) but do not tighten them.
   (7) Install the tank drain line (6) (Ref. AMM TASK 38-31-74-400-001).
CAUTION: MAKE SURE THAT THE BONDING STRAP(S) IS(ARE) CONNECTED BEFORE YOU CONNECT THE ELECTRICAL WIRE(S).
   (8) If applicable, install the bonding strap (9) as follows:
     (a) Put the bonding strap (9) in its correct installation position.
     (b) Install the bolt (10), the washer (11) and the nut (12).
     (c) Tighten the nut (12).
   (9) Do the electrical resistance measurement and the final protection of the bonding point(s)
(Ref. AMM TASK 20-28-00-912-802):
  • Make sure that the maximum bonding value at the bonding strap (9) is not more than 20 milliohms.
   (10) Connect the connections (29) of the rinse lines.
   (11) Install the water separator (Ref. AMM TASK 38-31-67-400-001).
   (12) Select the applicable new packings (28):
   (13) Apply a thin layer of Lubricant-Rubber seal Glycerin - (Material No.03PEB1) on the packings (28).
   (14) Install the packings (28) on the waste pipe ends.
   (15) Put the waste pipes (3), (4), (5), (7) and (8) in their correct installation positions.
   (16) Install the clamps (26) as follows:
     (a) Put the sleeves (27) in their correct installation positions.
     (b) Put the clamps (26) in their correct installation positions.
     (c) Install the clamps (26) and lock them.
     (d) Make sure that the clamps (26) are locked correctly:
  • The axial adjustment is not more than 6.35 mm (0.25 in.).
  • The angular misalignment is not more than +/- 4 degrees in all directions around the centerline.
   (17) Put the bracket (20) in its correct installation position.
   (18) Install the washers (19) and the screws (18).
   (19) Tighten the screws (18).
   (20) Put the clamps (23) in their correct installation positions.
   (21) Install the washers (22) and the screws (21).
   (22) Install the washers (24) and the nuts (25).
   (23) Tighten the nuts (25).
   (24) Install liquid level transmitter 40MG (Ref. AMM TASK 38-31-62-400-001).
   (25) Connect the pipe (15).
   (26) Remove the CAP-BLANKING from each electrical connector and receptacle.
CAUTION: MAKE SURE THAT THE ELECTRICAL CONNECTORS ARE CLEAN BEFORE YOU DISCONNECT OR CONNECT THEM. CONTAMINATION ON THE ELECTRICAL CONNECTORS CAN CAUSE DAMAGE TO EQUIPMENT.
   (27) Connect the electrical connectors (16) and (17).
   (28) Tighten the quick coupler clamps (2).
Subtask 38-31-61-420-052-C ** ON A/C NOT FOR ALL
A. Installation of Waste Holding Tank 3300MM
F Clamp Installation Requirements ** ON A/C NOT FOR ALL
   (1) Clean the component interfaces and the adjacent area.
   (2) Do an inspection of the component interfaces and the adjacent area.
   (3) Prepare the surface of the bonding point(s)
(Ref. AMM TASK 20-28-00-912-803).
   (4) Remove the PLUG-BLANKING from each disconnected line end.
   (5) Put waste holding tank 3300MM (1) in its correct installation position.
   (6) Install the quick coupler clamps (2) but do not tighten them.
   (7) Install the tank drain line (6) (Ref. AMM TASK 38-31-74-400-001).
CAUTION: MAKE SURE THAT THE BONDING STRAP(S) IS(ARE) CONNECTED BEFORE YOU CONNECT THE ELECTRICAL WIRE(S).
   (8) If applicable, install the bonding strap (9) as follows:
     (a) Put the bonding strap (9) in its correct installation position.
     (b) Install the bolt (10), the washer (11) and the nut (12).
     (c) Tighten the nut (12).
   (9) Do the electrical resistance measurement and the final protection of the bonding point(s)
(Ref. AMM TASK 20-28-00-912-802):
  • Make sure that the maximum bonding value at the bonding strap (9) is not more than 20 milliohms.
   (10) Connect the connections (29) of the rinse lines.
   (11) Install the water separator (Ref. AMM TASK 38-31-67-400-001).
   (12) Select the applicable new packings (28):
   (13) Apply a thin layer of Lubricant-Rubber seal Glycerin - (Material No.03PEB1) on the packings (28).
   (14) Install the packings (28) on the waste pipe ends.
   (15) Put the waste pipes (3), (4), (5), (7) and (8) in their correct installation positions.
   (16) Install the clamps (26) as follows:
     (a) Put the sleeves (27) in their correct installation positions.
     (b) Put the clamps (26) in their correct installation positions.
     (c) Install the clamps (26) and lock them.
     (d) Make sure that the clamps (26) are locked correctly:
  • The axial adjustment is not more than 6.35 mm (0.25 in.).
  • The angular misalignment is not more than +/- 4 degrees in all directions around the centerline.
   (17) Put the bracket (20) in its correct installation position.
   (18) Install the washers (19) and the screws (18).
   (19) Tighten the screws (18).
   (20) Put the clamps (23) in their correct installation positions.
   (21) Install the washers (22) and the screws (21).
   (22) Install the washers (24) and the nuts (25).
   (23) Tighten the nuts (25).
   (24) Install liquid level transmitter 40MG (Ref. AMM TASK 38-31-62-400-001).
   (25) Connect the pipe (15).
   (26) Remove the CAP-BLANKING from each electrical connector and receptacle.
CAUTION: MAKE SURE THAT THE ELECTRICAL CONNECTORS ARE CLEAN BEFORE YOU DISCONNECT OR CONNECT THEM. CONTAMINATION ON THE ELECTRICAL CONNECTORS CAN CAUSE DAMAGE TO EQUIPMENT.
   (27) Connect the electrical connectors (16) and (17).
   (28) Tighten the quick coupler clamps (2).
Subtask 38-31-61-420-052-D ** ON A/C NOT FOR ALL
A. Installation of Waste Holding Tank 3300MM
F Clamp Installation Requirements ** ON A/C NOT FOR ALL
   (1) Clean the component interfaces and the adjacent area.
   (2) Do an inspection of the component interfaces and the adjacent area.
   (3) When you connect/install the components, refer to the match marks made during the removal procedure.
   (4) Put waste holding tank 3300MM (1) in its installation position.
   (5) Install the clamps (4) but do not tighten them.
   (6) Install the waste tank drain-line (Ref. AMM TASK 38-31-74-400-001).
   (7) Connect the bonding strap:
     (a) Protect the bonding (Ref. AMM TASK 20-28-00-912-802).
CAUTION: MAKE SURE THAT THE BONDING STRAP(S) IS(ARE) CONNECTED BEFORE YOU CONNECT THE ELECTRICAL WIRE(S).
     (b) Put the bonding strap (5) in its installation position.
     (c) Install the bolt (19), the washer (20) and the nut (21).
   (8) Remove the PLUG-BLANKING from each disconnected line end.
   (9) Connect the rinse line connections (12) to the waste tank (1).
   (10) Install the water separator (Ref. AMM TASK 38-31-67-400-001).
   (11) Install the waste pipes (2), (3) and (6):
     (a) Install the waste pipe (3):
       1 Remove the PLUG-BLANKING from each disconnected line end.
       2 Put the waste pipe (3) in its installation position.
       3 Install the clamps (16).
       4 Install the washers (17) and the screws (18).
     (b) Connect the waste pipes (2), (3) and (6):
       1 Remove the PLUG-BLANKING from each disconnected line end.
       2 Select the applicable new packings (13):
       3 Apply a thin layer of Mineral Oil base Grease-- Vaseline or Petrolatum - (Material No.03FAB1) to the new packings (13).
       4 Put the waste pipes (2) and (6) in their installation positions.
       5 Put the packings (13) and the sleeves (15) in their installation positions.
       6 Connect the waste pipes (2), (3) and (6).
       7 Install the quick-coupler clamps (14) and lock them.
       8 Make sure that the quick-coupler clamps (14) are locked correctly:
  • The axial adjustment is not more than 6.35 mm (0.25 in.).
  • The angular misalignment is not more than +/- 4 deg. in all the directions around the centerline.
   (12) Install liquid level transmitter 40MG (8) (Ref. AMM TASK 38-31-62-400-001).
   (13) Remove the PLUG-BLANKING from each disconnected line end.
   (14) Connect the connection (7) to liquid level transmitter 40MG (8).
   (15) Connect the electrical connectors:
     (a) Remove the CAP-BLANKING from each electrical connector and receptacle.
CAUTION: MAKE SURE THAT THE ELECTRICAL CONNECTORS ARE CLEAN BEFORE YOU DISCONNECT OR CONNECT THEM. CONTAMINATION ON THE ELECTRICAL CONNECTORS CAN CAUSE DAMAGE TO EQUIPMENT.
     (b) Connect the electrical connectors (9) and (11).
   (16) Tighten the clamps (4).
Subtask 38-31-61-420-052-E ** ON A/C NOT FOR ALL
A. Installation of Waste Holding Tank 3300MM
F Clamp Installation Requirements ** ON A/C NOT FOR ALL
   (1) Clean the component interfaces and the adjacent area.
   (2) Do an inspection of the component interfaces and the adjacent area.
   (3) When you connect/install the components, refer to the match marks made during the removal procedure.
   (4) Put waste holding tank 3300MM (1) in its installation position.
   (5) Install the clamps (4) but do not tighten them.
   (6) Install the waste tank drain-line (Ref. AMM TASK 38-31-74-400-001).
   (7) Remove the PLUG-BLANKING from each disconnected line end.
   (8) Connect the rinse line connections (12) to the waste tank (1).
   (9) Install the water separator (Ref. AMM TASK 38-31-67-400-001).
   (10) Install the waste pipes (2), (3) and (6):
     (a) Install the waste pipes (3) and (6):
       1 Remove the PLUG-BLANKING from each disconnected line end.
       2 Put the waste pipes (3) and (6) in their installation positions.
       3 Hold the waste pipes (3) and (6).
       4 Install the clamps (16).
       5 Install the washers (17) and the screws (18).
     (b) Connect the waste pipes (2), (3) and (6):
       1 Remove the PLUG-BLANKING from each disconnected line end.
       2 Apply a thin layer of Mineral Oil base Grease-- Vaseline or Petrolatum - (Material No.03FAB1) to the new AIPC 38-31-84-32-013 PACKING (13).
       3 Put the waste pipe (2) in its installation position.
       4 Put the O-rings (13) and the sleeves (15) in their installation position.
       5 Connect the waste pipes (2), (3) and (6).
       6 Install the quick-coupler clamps (14) and lock them.
       7 Make sure that the quick-coupler clamps (14) are locked correctly:
  • The axial adjustment is not more than 6.35 mm (0.25 in.).
  • The angular misalignment is not more than +/- 4 deg. in all the directions around the centerline.
   (11) Install liquid level transmitter 40MG (8) (
Ref. AMM TASK 38-31-62-400-001).
   (12) Remove the PLUG-BLANKING from each disconnected line end.
   (13) Connect the connection (7) to liquid level transmitter 40MG (8).
   (14) Connect the bonding strap:
     (a) Protect the bonding (Ref. AMM TASK 20-28-00-912-802).
CAUTION: MAKE SURE THAT THE BONDING STRAP(S) IS(ARE) CONNECTED BEFORE YOU CONNECT THE ELECTRICAL WIRE(S).
     (b) Put the bonding strap (5) in its installation position.
     (c) Install the bolt (19), the washer (20) and the nut (21).
   (15) Connect the electrical connectors:
     (a) Remove the CAP-BLANKING from each electrical connector and receptacle.
CAUTION: MAKE SURE THAT THE ELECTRICAL CONNECTORS ARE CLEAN BEFORE YOU DISCONNECT OR CONNECT THEM. CONTAMINATION ON THE ELECTRICAL CONNECTORS CAN CAUSE DAMAGE TO EQUIPMENT.
     (b) Connect the electrical connectors (9) and (11).
   (16) TORQUE the clamps (4) to between 10.16 and 9.04 m.N (89.91 and 80.00 lbf.in ) T.
Subtask 38-31-61-865-072-A
B. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
2001VUVACU TOIL SYS-VACUUM-SYS35MGA06
** ON A/C NOT FOR ALL
2001VUVACU TOIL SYS-VACUUM-GEN33MGA08
** ON A/C NOT FOR ALL
2001VUVACU TOIL SYS-LAV PWR-E34MGA04
** ON A/C NOT FOR ALL
2001VUVACU TOIL SYS-LAV PWR-D39MGA03
** ON A/C ALL
2001VUVACU TOIL SYS-LAV PWR-A32MGA01
** ON A/C NOT FOR ALL
2001VUVACU TOIL SYS-VACU-SYS35MGA06
** ON A/C NOT FOR ALL
2001VUVACU TOIL SYS-VACU-GEN33MGA08
** ON A/C NOT FOR ALL
2001VUVACU TOIL SYS-LAV PWR-G34MGA04
2001VUVACU TOIL SYS-LAV PWR-F39MGA03
2001VUVACU TOIL SYS-LAV PWR-D45MGA02
** ON A/C NOT FOR ALL
2001VUVACU TOIL SYS-LAV PWR-L45MGA02
** ON A/C NOT FOR ALL
2001VUVACU TOIL SYS-LAV PWR-L23MGA05
** ON A/C NOT FOR ALL
2001VUVACU TOIL SYS-LAV PWR-M34MGA04
Subtask 38-31-61-790-051-A
C. Leak Test
   (1) Do the leak test of the vacuum toilet system (
Ref. AMM TASK 38-31-00-790-002).
   (2) Record the results of the test.
   (3) Compare the results of the leak test recorded before the removal and after the installation of the component.
   (4) Make sure that the test results recorded after the installation are not more than 10% of the test results recorded before the removal.
Subtask 38-31-61-710-050-A
D. Operational Test
   (1) Operate the toilet and make sure that it flushes correctly (Ref. AMM TASK 38-31-00-710-009).
5. Close-up
Subtask 38-31-61-410-054-C
A. Close Access
   (1) If you removed the insulation around the waste holding tank, install it.
   (2) Make sure that the work area is clean and clear of tools and other items.
   (3) Install the center support strut at FR65 (Ref. AMM TASK 53-43-11-400-001).
   (4) Install partitions 161DW and 162DW (Ref. AMM TASK 25-55-12-400-001).
   (5) Set cargo-compartment light switch 8LU to OFF.
   (6) Remove the access platform(s).
   (7) Close aft cargo-compartment door 826 (Ref. AMM TASK 52-30-00-860-002) or (Ref. AMM TASK 52-30-00-860-004).
Subtask 38-31-61-862-050-A
B. De-energize the ground service network (Ref. AMM TASK 24-42-00-862-001).