Removal of the Vacuum System Controller
TASK 38-31-34-000-001-A
Removal of the Vacuum System Controller
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 38-31-34-861-050-A ** ON A/C NOT FOR ALL Subtask 38-31-34-865-058-A ** ON A/C NOT FOR ALL
Subtask 38-31-34-020-050-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.01 01:20:21 UTC
Removal of the Vacuum System Controller
FIN: 31MG ** ON A/C NOT FOR ALL
1. Reason for the JobSelf explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | ACCESS PLATFORM 1M(3 FT) |
| No specific | AR | SAFETY CLIP - CIRCUIT BREAKER |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 162AW, 162BW | |
| 162GW |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-42-00-861-001-A | Energize the Ground Service Network from the External Power |
| TASK 52-30-00-860-001-A | Open the FWD or Aft Cargo-Compartment Door with the Yellow Electric Pump |
Subtask 38-31-34-861-050-A ** ON A/C NOT FOR ALL Subtask 38-31-34-865-058-A ** ON A/C NOT FOR ALL
B. Open, safety and tag this(these) circuit breaker(s):
Subtask 38-31-34-010-050-A ** ON A/C NOT FOR ALL | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 2001VU | VACU TOIL SYS-VACUUM-SYS | 35MG | A06 |
| ** ON A/C NOT FOR ALL | |||
| 2001VU | VACU TOIL SYS-VACUUM-GEN | 33MG | A08 |
| 2001VU | VACU TOIL SYS-LAV PWR-E | 34MG | A04 |
| 2001VU | VACU TOIL SYS-LAV PWR-D | 39MG | A03 |
| 2001VU | VACU TOIL SYS-LAV PWR-A | 32MG | A01 |
| ** ON A/C NOT FOR ALL | |||
| 2001VU | VACU TOIL SYS-VACU-SYS | 35MG | A06 |
| 2001VU | VACU TOIL SYS-LAV PWR-L | 45MG | A02 |
C. Get Access
(1) Put the ACCESS PLATFORM 1M(3 FT) in position.
(2) Open the AFT cargo-compartment door (Ref. AMM TASK 52-30-00-860-001).
(3) Remove the access panel 162BW and if necessary the access panel 162AW.
Subtask 38-31-34-010-050-B ** ON A/C NOT FOR ALL (1) Put the ACCESS PLATFORM 1M(3 FT) in position.
(2) Open the AFT cargo-compartment door (Ref. AMM TASK 52-30-00-860-001).
(3) Remove the access panel 162BW and if necessary the access panel 162AW.
C. Get Access
(1) Put the ACCESS PLATFORM 1M(3 FT) in position.
(2) Open the BULK cargo-compartment door.
(3) Remove the aft corner section and the access panel 162GW.
4. Procedure(1) Put the ACCESS PLATFORM 1M(3 FT) in position.
(2) Open the BULK cargo-compartment door.
(3) Remove the aft corner section and the access panel 162GW.
Subtask 38-31-34-020-050-A ** ON A/C NOT FOR ALL
A. Removal of the Vacuum System Controller 31MG
(1) Loosen the fastener (1).
(2) Remove the vacuum controller (2).
(1) Loosen the fastener (1).
(2) Remove the vacuum controller (2).
Vacuum System Controller