W DOC AIRBUS | AMM A320F

Removal of the Vacuum System Controller


TASK 38-31-34-000-001-A
Removal of the Vacuum System Controller


FIN: 31MG ** ON A/C NOT FOR ALL
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
1
ACCESS PLATFORM 1M(3 FT)
No specific
AR
SAFETY CLIP - CIRCUIT BREAKER
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
162AW, 162BW
162GW
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 24-42-00-861-001-A
Energize the Ground Service Network from the External Power
TASK 52-30-00-860-001-A
Open the FWD or Aft Cargo-Compartment Door with the Yellow Electric Pump
3. Job Set-up
Subtask 38-31-34-861-050-A ** ON A/C NOT FOR ALL
A. Energize the ground service network
(Ref. AMM TASK 24-42-00-861-001).
Subtask 38-31-34-865-058-A ** ON A/C NOT FOR ALL
B. Open, safety and tag this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
2001VUVACU TOIL SYS-VACUUM-SYS35MGA06
** ON A/C NOT FOR ALL
2001VUVACU TOIL SYS-VACUUM-GEN33MGA08
2001VUVACU TOIL SYS-LAV PWR-E34MGA04
2001VUVACU TOIL SYS-LAV PWR-D39MGA03
2001VUVACU TOIL SYS-LAV PWR-A32MGA01
** ON A/C NOT FOR ALL
2001VUVACU TOIL SYS-VACU-SYS35MGA06
2001VUVACU TOIL SYS-LAV PWR-L45MGA02
Subtask 38-31-34-010-050-A ** ON A/C NOT FOR ALL
C. Get Access
   (1) Put the ACCESS PLATFORM 1M(3 FT) in position.
   (2) Open the AFT cargo-compartment door (Ref. AMM TASK 52-30-00-860-001).
   (3) Remove the access panel 162BW and if necessary the access panel 162AW.
Subtask 38-31-34-010-050-B ** ON A/C NOT FOR ALL
C. Get Access
   (1) Put the ACCESS PLATFORM 1M(3 FT) in position.
   (2) Open the BULK cargo-compartment door.
   (3) Remove the aft corner section and the access panel 162GW.
4. Procedure
Subtask 38-31-34-020-050-A ** ON A/C NOT FOR ALL
A. Removal of the Vacuum System Controller 31MG
   (1) Loosen the fastener (1).
   (2) Remove the vacuum controller (2).
[Rev.10 from 2021] 2026.04.01 01:20:21 UTC