W DOC AIRBUS | AMM A320F

Operational Test of the Door Limit Switch


TASK 38-31-00-710-008-A
Operational Test of the Door Limit Switch


FIN: 44MG
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
1
ACCESS PLATFORM 3M (10 FT)
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
172AR
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 24-42-00-861-001-A
Energize the Ground Service Network from the External Power
TASK 24-42-00-862-001-A
De-energize the Ground Service Network Supplied from the External Power
3. Job Set-up
Subtask 38-31-00-861-059-A
A. Energize the ground service network
(Ref. AMM TASK 24-42-00-861-001).
Subtask 38-31-00-865-123-A
B. Make sure that this(these) circuit breaker(s) is(are) closed:
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
2001VUVACU TOIL SYS-VACUUM-SYS35MGA06
** ON A/C NOT FOR ALL
2001VUVACU TOIL SYS-VACUUM-GEN33MGA08
** ON A/C NOT FOR ALL
2001VUVACU TOIL SYS-LAV PWR-E34MGA04
** ON A/C NOT FOR ALL
2001VUVACU TOIL SYS-LAV PWR-D39MGA03
** ON A/C ALL
2001VUVACU TOIL SYS-LAV PWR-A32MGA01
** ON A/C NOT FOR ALL
2001VUVACU TOIL SYS-VACU-SYS35MGA06
** ON A/C NOT FOR ALL
2001VUVACU TOIL SYS-VACU-GEN33MGA08
** ON A/C NOT FOR ALL
2001VUVACU TOIL SYS-LAV PWR-G34MGA04
2001VUVACU TOIL SYS-LAV PWR-F39MGA03
2001VUVACU TOIL SYS-LAV PWR-D45MGA02
** ON A/C NOT FOR ALL
2001VUVACU TOIL SYS-LAV PWR-L45MGA02
** ON A/C NOT FOR ALL
2001VUVACU TOIL SYS-LAV PWR-L23MGA05
** ON A/C NOT FOR ALL
2001VUVACU TOIL SYS-LAV PWR-M34MGA04
Subtask 38-31-00-010-071-A
C. Get Access
   (1) Put an ACCESS PLATFORM 3M (10 FT) in position under the waste service panel.
   (2) Open the waste service-panel door 172AR.
4. Procedure
Subtask 38-31-00-710-061-A
A. Operational Test of the Waste-Service Panel Door-Switch 44MG
ACTION
RESULT
1.At the waste service panel:
  • make sure that the waste service-panel door 172AR is open.
On the Forward Attendants Panel (FAP) 120RH/miscellaneous panel WATER AND WASTE 124RH:
  • the SYSTEM INOP message is shown.
2.In a lavatory:
  • push the toilet flush switch.
In the Zone 170:
  • the vacuum generator 37MG does not operate.

In the lavatory:
  • the toilet does not flush.
3.At the waste service panel:
  • close the waste service-panel door 172AR.
On the FAP 120RH/miscellaneous panel WATER AND WASTE 124RH:
  • the SYSTEM INOP message goes off.
4.In a lavatory:
  • push the toilet flush switch.
In the Zone 170:
  • the vacuum generator 37MG starts to operate.

In the lavatory:
  • the toilet flushes.
NOTE: If the potable water tank is empty the toilet flush will operate but there will be no water spray in the toilet bowl.
5. Close-up
Subtask 38-31-00-410-069-A
A. Close Access
   (1) Make sure that the work area is clean and clear of tools and other items.
   (2) Close the waste service-panel door 172AR.
NOTE: Make sure that the latches are correctly locked and that the door makes a continuous surface with the skin of the aircraft.
   (3) Remove the access platform(s).
Subtask 38-31-00-862-059-A
B. De-energize the ground service network
(Ref. AMM TASK 24-42-00-862-001).
[Rev.10 from 2021] 2026.04.01 01:19:51 UTC