Operational Test of the Vacuum Toilet System (vacuum generator not working)
TASK 38-31-00-710-007-A
Operational Test of the Vacuum Toilet System (vacuum generator not working)
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Referenced Information
3. Job Set-up
Subtask 38-31-00-861-057-A Subtask 38-31-00-010-066-A
Subtask 38-31-00-710-057-A
Subtask 38-31-00-680-054-A Subtask 38-31-00-613-059-A Subtask 38-31-00-410-065-A
[Rev.10 from 2021]
2026.04.01 01:19:46 UTC
Operational Test of the Vacuum Toilet System (vacuum generator not working)
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| TASK 12-16-38-613-001-A | Servicing of the Toilet System |
| TASK 24-42-00-861-001-A | Energize the Ground Service Network from the External Power |
| TASK 24-42-00-862-001-A | De-energize the Ground Service Network Supplied from the External Power |
| TASK 38-31-00-680-001-A | Draining of the Toilet System |
Subtask 38-31-00-861-057-A Subtask 38-31-00-010-066-A
B. Get Access
(1) Get access to the cabin.
(2) Open the lavatory door (s).
Subtask 38-31-00-865-120-A (1) Get access to the cabin.
(2) Open the lavatory door (s).
C. Make sure that this(these) circuit breaker(s) is(are) closed:
4. Procedure| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 2001VU | VACU TOIL SYS-VACUUM-SYS | 35MG | A06 |
| ** ON A/C NOT FOR ALL | |||
| 2001VU | VACU TOIL SYS-VACUUM-GEN | 33MG | A08 |
| ** ON A/C NOT FOR ALL | |||
| 2001VU | VACU TOIL SYS-LAV PWR-E | 34MG | A04 |
| ** ON A/C NOT FOR ALL | |||
| 2001VU | VACU TOIL SYS-LAV PWR-D | 39MG | A03 |
| ** ON A/C ALL | |||
| 2001VU | VACU TOIL SYS-LAV PWR-A | 32MG | A01 |
| ** ON A/C NOT FOR ALL | |||
| 2001VU | VACU TOIL SYS-VACU-SYS | 35MG | A06 |
| ** ON A/C NOT FOR ALL | |||
| 2001VU | VACU TOIL SYS-VACU-GEN | 33MG | A08 |
| ** ON A/C NOT FOR ALL | |||
| 2001VU | VACU TOIL SYS-LAV PWR-G | 34MG | A04 |
| 2001VU | VACU TOIL SYS-LAV PWR-F | 39MG | A03 |
| 2001VU | VACU TOIL SYS-LAV PWR-D | 45MG | A02 |
| ** ON A/C NOT FOR ALL | |||
| 2001VU | VACU TOIL SYS-LAV PWR-L | 45MG | A02 |
| ** ON A/C NOT FOR ALL | |||
| 2001VU | VACU TOIL SYS-LAV PWR-L | 23MG | A05 |
| ** ON A/C NOT FOR ALL | |||
| 2001VU | VACU TOIL SYS-LAV PWR-M | 34MG | A04 |
Subtask 38-31-00-710-057-A
A. Do this test.
5. Close-up| ACTION | RESULT |
|---|---|
1.In one lavatory:
| In the vacuum toilet system:
|
NOTE: Make sure that the toilet flush valve of each lavatory opens and closes correctly.
Subtask 38-31-00-680-054-A Subtask 38-31-00-613-059-A Subtask 38-31-00-410-065-A
C. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the lavatory door (s).
Subtask 38-31-00-862-057-A (1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the lavatory door (s).