W DOC AIRBUS | AMM A320F

Operational Test of the Vacuum Toilet System (vacuum generator not working)


TASK 38-31-00-710-007-A
Operational Test of the Vacuum Toilet System (vacuum generator not working)


1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
TASK 12-16-38-613-001-A
Servicing of the Toilet System
TASK 24-42-00-861-001-A
Energize the Ground Service Network from the External Power
TASK 24-42-00-862-001-A
De-energize the Ground Service Network Supplied from the External Power
TASK 38-31-00-680-001-A
Draining of the Toilet System
3. Job Set-up
Subtask 38-31-00-861-057-A
A. Energize the ground service network
(Ref. AMM TASK 24-42-00-861-001).
Subtask 38-31-00-010-066-A
B. Get Access
   (1) Get access to the cabin.
   (2) Open the lavatory door (s).
Subtask 38-31-00-865-120-A
C. Make sure that this(these) circuit breaker(s) is(are) closed:
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
2001VUVACU TOIL SYS-VACUUM-SYS35MGA06
** ON A/C NOT FOR ALL
2001VUVACU TOIL SYS-VACUUM-GEN33MGA08
** ON A/C NOT FOR ALL
2001VUVACU TOIL SYS-LAV PWR-E34MGA04
** ON A/C NOT FOR ALL
2001VUVACU TOIL SYS-LAV PWR-D39MGA03
** ON A/C ALL
2001VUVACU TOIL SYS-LAV PWR-A32MGA01
** ON A/C NOT FOR ALL
2001VUVACU TOIL SYS-VACU-SYS35MGA06
** ON A/C NOT FOR ALL
2001VUVACU TOIL SYS-VACU-GEN33MGA08
** ON A/C NOT FOR ALL
2001VUVACU TOIL SYS-LAV PWR-G34MGA04
2001VUVACU TOIL SYS-LAV PWR-F39MGA03
2001VUVACU TOIL SYS-LAV PWR-D45MGA02
** ON A/C NOT FOR ALL
2001VUVACU TOIL SYS-LAV PWR-L45MGA02
** ON A/C NOT FOR ALL
2001VUVACU TOIL SYS-LAV PWR-L23MGA05
** ON A/C NOT FOR ALL
2001VUVACU TOIL SYS-LAV PWR-M34MGA04
4. Procedure
Subtask 38-31-00-710-057-A
A. Do this test.
ACTION
RESULT
1.In one lavatory:
  • push the flush switch 51MG.
In the vacuum toilet system:
  • approx. 0.2 l (0.05 USgal) of water flows into the toilet bowl.
  • the toilet flush valve opens and the water drains out of the toilet bowl.
  • you hear the toilet flush valve close when the water is drained.
  • no indication on the FAP and no CFDS data.
NOTE: Make sure that the toilet flush valve of each lavatory opens and closes correctly.
5. Close-up
Subtask 38-31-00-680-054-A
A. If necessary drain the toilet system (Ref. AMM TASK 38-31-00-680-001).
Subtask 38-31-00-613-059-A
B. If necessary do the servicing of the toilet system (Ref. AMM TASK 12-16-38-613-001).
Subtask 38-31-00-410-065-A
C. Close Access
   (1) Make sure that the work area is clean and clear of tools and other items.
   (2) Close the lavatory door (s).
Subtask 38-31-00-862-057-A
D. De-energize the ground service network
(Ref. AMM TASK 24-42-00-862-001).
[Rev.10 from 2021] 2026.04.01 01:19:46 UTC