W DOC AIRBUS | AMM A320F

Cleaning of Vacuum Waste Lines with Chemical Cleaning Agent (and Crushed Ice)


TASK 38-31-00-100-805-A
Cleaning of Vacuum Waste Lines with Chemical Cleaning Agent (and Crushed Ice)


WARNING: BE CAREFUL WHEN YOU USE CONSUMABLE MATERIALS. OBEY THE MATERIAL MANUFACTURER'S INSTRUCTIONS AND YOUR LOCAL REGULATIONS.
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Consumable Materials
REFERENCE
DESIGNATION
(Material No.08AHB1)
Aqueous Cleaner-Toilet System Preventive De-scaling -
(Material No.08CEB8)
Cleaner-Toilet System Specific -
(Material No.11GCA1)
Deodorant-Aircraft Toilets - -
(Material No.14SBA1)
Textile-Lint free Cotton -
 B. Referenced Information
REFERENCE
DESIGNATION
TASK 12-16-38-613-001-A
Servicing of the Toilet System
TASK 24-42-00-861-001-A
Energize the Ground Service Network from the External Power
TASK 24-42-00-862-001-A
De-energize the Ground Service Network Supplied from the External Power
TASK 38-10-00-614-001-A
Pressurization of the Potable Water System from a Ground Air Supply
TASK 38-10-00-614-003-A
Pressurization of the Potable Water System with the Compressor
3. Job Set-up
Subtask 38-31-00-861-090-A
A. Aircraft Maintenance Configuration
   (1) Energize the ground service network
(Ref. AMM TASK 24-42-00-861-001).
Subtask 38-31-00-010-106-A
B. Get Access
   (1) Get access to the lavatories.
Subtask 38-31-00-865-140-A
C. Make sure that this(these) circuit breaker(s) is(are) closed:
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
2001VUVACU TOIL SYS-VACUUM-SYS35MGA06
** ON A/C NOT FOR ALL
2001VUVACU TOIL SYS-VACUUM-GEN33MGA08
** ON A/C NOT FOR ALL
2001VUVACU TOIL SYS-LAV PWR-E34MGA04
** ON A/C NOT FOR ALL
2001VUVACU TOIL SYS-LAV PWR-D39MGA03
** ON A/C ALL
2001VUVACU TOIL SYS-LAV PWR-A32MGA01
** ON A/C NOT FOR ALL
2001VUVACU TOIL SYS-VACU-SYS35MGA06
** ON A/C NOT FOR ALL
2001VUVACU TOIL SYS-VACU-GEN33MGA08
** ON A/C NOT FOR ALL
2001VUVACU TOIL SYS-LAV PWR-G34MGA04
2001VUVACU TOIL SYS-LAV PWR-F39MGA03
2001VUVACU TOIL SYS-LAV PWR-D45MGA02
** ON A/C NOT FOR ALL
2001VUVACU TOIL SYS-LAV PWR-L45MGA02
** ON A/C NOT FOR ALL
2001VUVACU TOIL SYS-LAV PWR-L23MGA05
** ON A/C NOT FOR ALL
2001VUVACU TOIL SYS-LAV PWR-M34MGA04
Subtask 38-31-00-860-079-A
D. Aircraft Maintenance Configuration
   (1) Do the servicing of the waste holding tank (Ref. AMM TASK 12-16-38-613-001).
   (2) Make sure that the potable water system is pressurized (Ref. AMM TASK 38-10-00-614-001) (Ref. AMM TASK 38-10-00-614-003).
4. Procedure
Subtask 38-31-00-100-066-A
A. Cleaning the Toilet Waste Lines
WARNING: ALWAYS WEAR RUBBER GLOVES, GOGGLES AND PROTECTIVE CLOTHES WHEN YOU DO THIS TASK.
   (1) Use the Cleaner-Toilet System Specific - (Material No.08CEB8) or Deodorant-Aircraft Toilets - - (Material No.11GCA1) or Aqueous Cleaner-Toilet System Preventive De-scaling - (Material No.08AHB1) .
   (2) Refer to the recommendation of the cleaning agent supplier and to the airline experience.
5. Close-up
Subtask 38-31-00-613-077-A
A. Aircraft Maintenance Configuration
   (1) Do the servicing of the waste system (Ref. AMM TASK 12-16-38-613-001).
Subtask 38-31-00-410-112-A
B. Close Access
   (1) Dry the area around the toilet with Textile-Lint free Cotton - (Material No.14SBA1) .
   (2) Make sure that the work area is clean and clear of tools and other items.
   (3) Close the lavatory door(s).
Subtask 38-31-00-862-088-A
C. Put the aircraft back to its initial configuration.
   (1) De-energize the ground service network
(Ref. AMM TASK 24-42-00-862-001).
[Rev.10 from 2021] 2026.04.01 01:20:12 UTC