Cleaning of Vacuum Waste Lines with Chemical Cleaning Agent (and Crushed Ice)
TASK 38-31-00-100-805-A
Cleaning of Vacuum Waste Lines with Chemical Cleaning Agent (and Crushed Ice)
Self explanatory
2. Job Set-up Information
A. Consumable Materials
B. Referenced Information
3. Job Set-up
Subtask 38-31-00-861-090-A
Subtask 38-31-00-100-066-A
Subtask 38-31-00-613-077-A
[Rev.10 from 2021]
2026.04.01 01:20:12 UTC
Cleaning of Vacuum Waste Lines with Chemical Cleaning Agent (and Crushed Ice)
WARNING:
BE CAREFUL WHEN YOU USE CONSUMABLE MATERIALS. OBEY THE MATERIAL MANUFACTURER'S INSTRUCTIONS AND YOUR LOCAL REGULATIONS.
1. Reason for the JobSelf explanatory
2. Job Set-up Information
A. Consumable Materials
| REFERENCE | DESIGNATION |
|---|---|
| (Material No.08AHB1) | Aqueous Cleaner-Toilet System Preventive De-scaling - |
| (Material No.08CEB8) | Cleaner-Toilet System Specific - |
| (Material No.11GCA1) | Deodorant-Aircraft Toilets - - |
| (Material No.14SBA1) | Textile-Lint free Cotton - |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 12-16-38-613-001-A | Servicing of the Toilet System |
| TASK 24-42-00-861-001-A | Energize the Ground Service Network from the External Power |
| TASK 24-42-00-862-001-A | De-energize the Ground Service Network Supplied from the External Power |
| TASK 38-10-00-614-001-A | Pressurization of the Potable Water System from a Ground Air Supply |
| TASK 38-10-00-614-003-A | Pressurization of the Potable Water System with the Compressor |
Subtask 38-31-00-861-090-A
A. Aircraft Maintenance Configuration
(1) Energize the ground service network
(Ref. AMM TASK 24-42-00-861-001).
Subtask 38-31-00-010-106-A (1) Energize the ground service network
(Ref. AMM TASK 24-42-00-861-001).
B. Get Access
(1) Get access to the lavatories.
Subtask 38-31-00-865-140-A (1) Get access to the lavatories.
C. Make sure that this(these) circuit breaker(s) is(are) closed:
Subtask 38-31-00-860-079-A | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 2001VU | VACU TOIL SYS-VACUUM-SYS | 35MG | A06 |
| ** ON A/C NOT FOR ALL | |||
| 2001VU | VACU TOIL SYS-VACUUM-GEN | 33MG | A08 |
| ** ON A/C NOT FOR ALL | |||
| 2001VU | VACU TOIL SYS-LAV PWR-E | 34MG | A04 |
| ** ON A/C NOT FOR ALL | |||
| 2001VU | VACU TOIL SYS-LAV PWR-D | 39MG | A03 |
| ** ON A/C ALL | |||
| 2001VU | VACU TOIL SYS-LAV PWR-A | 32MG | A01 |
| ** ON A/C NOT FOR ALL | |||
| 2001VU | VACU TOIL SYS-VACU-SYS | 35MG | A06 |
| ** ON A/C NOT FOR ALL | |||
| 2001VU | VACU TOIL SYS-VACU-GEN | 33MG | A08 |
| ** ON A/C NOT FOR ALL | |||
| 2001VU | VACU TOIL SYS-LAV PWR-G | 34MG | A04 |
| 2001VU | VACU TOIL SYS-LAV PWR-F | 39MG | A03 |
| 2001VU | VACU TOIL SYS-LAV PWR-D | 45MG | A02 |
| ** ON A/C NOT FOR ALL | |||
| 2001VU | VACU TOIL SYS-LAV PWR-L | 45MG | A02 |
| ** ON A/C NOT FOR ALL | |||
| 2001VU | VACU TOIL SYS-LAV PWR-L | 23MG | A05 |
| ** ON A/C NOT FOR ALL | |||
| 2001VU | VACU TOIL SYS-LAV PWR-M | 34MG | A04 |
D. Aircraft Maintenance Configuration
(1) Do the servicing of the waste holding tank (Ref. AMM TASK 12-16-38-613-001).
(2) Make sure that the potable water system is pressurized (Ref. AMM TASK 38-10-00-614-001) (Ref. AMM TASK 38-10-00-614-003).
4. Procedure(1) Do the servicing of the waste holding tank (Ref. AMM TASK 12-16-38-613-001).
(2) Make sure that the potable water system is pressurized (Ref. AMM TASK 38-10-00-614-001) (Ref. AMM TASK 38-10-00-614-003).
Subtask 38-31-00-100-066-A
A. Cleaning the Toilet Waste Lines
(2) Refer to the recommendation of the cleaning agent supplier and to the airline experience.
5. Close-upWARNING:
ALWAYS WEAR RUBBER GLOVES, GOGGLES AND PROTECTIVE CLOTHES WHEN YOU DO THIS TASK.
(1) Use the Cleaner-Toilet System Specific - (Material No.08CEB8) or Deodorant-Aircraft Toilets - - (Material No.11GCA1) or Aqueous Cleaner-Toilet System Preventive De-scaling - (Material No.08AHB1) . (2) Refer to the recommendation of the cleaning agent supplier and to the airline experience.
Subtask 38-31-00-613-077-A
A. Aircraft Maintenance Configuration
(1) Do the servicing of the waste system (Ref. AMM TASK 12-16-38-613-001).
Subtask 38-31-00-410-112-A (1) Do the servicing of the waste system (Ref. AMM TASK 12-16-38-613-001).
B. Close Access
(1) Dry the area around the toilet with Textile-Lint free Cotton - (Material No.14SBA1) .
(2) Make sure that the work area is clean and clear of tools and other items.
(3) Close the lavatory door(s).
Subtask 38-31-00-862-088-A (1) Dry the area around the toilet with Textile-Lint free Cotton - (Material No.14SBA1) .
(2) Make sure that the work area is clean and clear of tools and other items.
(3) Close the lavatory door(s).
C. Put the aircraft back to its initial configuration.
(1) De-energize the ground service network
(Ref. AMM TASK 24-42-00-862-001).
(1) De-energize the ground service network
(Ref. AMM TASK 24-42-00-862-001).