W DOC AIRBUS | AMM A320F

Special Cleaning of the Waste Tank Area and Related Component Inspections


TASK 38-31-00-100-014-A
Special Cleaning of the Waste Tank Area and Related Component Inspections


WARNING: DO NOT DO WORK ON THE TOILET WASTE SYSTEM AND THE POTABLE WATER SYSTEM AT THE SAME TIME. THIS WILL PREVENT CONTAMINATION OF THE POTABLE WATER SYSTEM. SUCH CONTAMINATION CAN BE DANGEROUS TO HEALTH.
WARNING: ALWAYS USE RUBBER GLOVES WHEN YOU DO WORK:
  • ON THE TOILET WASTE SYSTEM, OR
  • ON PARTS THAT HAVE CONTAMINATION FROM THE WASTE SYSTEM.
WHEN YOU COMPLETE THE WORK PROCEDURE, CLEAN YOUR HANDS WITH SOAP AND WATER. THIS WILL PREVENT INFECTION (TOILET WASTE IS DANGEROUS FOR HEALTH).
WARNING: WHEN YOU REMOVE A COMPONENT OF THE TOILET WASTE SYSTEM, ALWAYS DISINFECT THE PART BEFORE YOU PUT IT IN A PLASTIC BAG, THEN SEAL THE BAG. DO NOT PUT DOCUMENTS INTO THE PLASTIC BAG. SEAL THE BAG FIRST,THEN ATTACH THE DOCUMENTS TO IT. THIS WILL PREVENT INFECTION OR ILLNESS. CONTAMINATION FROM THE WASTE CAN BE DANGEROUS TO HEALTH.
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
1
ACCESS PLATFORM 2M (6 FT)
No specific
1
GUN - SPRAY
No specific
AR
SAFETY BARRIER(S)
 B. Consumable Materials
REFERENCE
DESIGNATION
(Material No.08BAA9)
Non Aqueous Cleaner-General - -
(Material No.11AAA2)
Disinfectant-Aircraft General - -
 C. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
161DW, 162DW
 D. Referenced Information
REFERENCE
DESIGNATION
TASK 12-21-12-670-001-A
Disinfection of the Aircraft Equipment and Furnishing
TASK 21-31-51-000-001-A
Removal of the Outflow Valve (From Inside)
TASK 21-31-51-400-001-A
Installation of the Outflow Valve (From Inside)
TASK 24-42-00-861-001-A
Energize the Ground Service Network from the External Power
TASK 24-42-00-862-001-A
De-energize the Ground Service Network Supplied from the External Power
TASK 38-31-61-000-001-A
Removal of the Waste Holding Tank
TASK 38-31-61-400-001-A
Installation of the Waste Holding Tank
TASK 38-31-62-000-001-A
Removal of the Liquid Level Transmitter
TASK 38-31-62-400-001-A
Installation of the Liquid Level Transmitter
TASK 38-31-63-000-001-A
Removal of the Liquid Level Sensor
TASK 38-31-63-400-001-A
Installation of the Liquid Level Sensor
TASK 38-31-64-000-001-A
Removal of the Vacuum Generator
TASK 38-31-64-400-001-A
Installation of the Vacuum Generator
TASK 38-31-67-000-001-A
Removal of the Water Separator
TASK 38-31-67-400-001-A
Installation of the Water Separator
TASK 51-78-00-615-001-A
Aircraft Cleaning after a Sewage Leakage
TASK 52-30-00-860-001-A
Open the FWD or Aft Cargo-Compartment Door with the Yellow Electric Pump
SRM 517815
(for corrective action)
3. Job Set-up
Subtask 38-31-00-861-078-A
A. Energize the ground service network
(Ref. AMM TASK 24-42-00-861-001).
Subtask 38-31-00-941-069-A
B. Safety Precautions
   (1) As necessary, use the applicable SAFETY BARRIERS, specified by the operator's instructions and your local regulations.
   (2) Put the warning notices in position to tell persons not to use the toilet system.
Subtask 38-31-00-010-094-A
C. Get Access
   (1) Open the AFT cargo-compartment door (Ref. AMM TASK 52-30-00-860-001).
   (2) Put the ACCESS PLATFORM 2M (6 FT) in position at Zone 172.
   (3) Remove the access panels 161DW and 162DW.
Subtask 38-31-00-860-070-A
D. Aircraft Configuration
   (1) Make sure the waste holding tank is removed (Ref. AMM TASK 38-31-61-000-001).
   (2) Remove the insulation blankets from the contaminated area.
4. Procedure
Subtask 38-31-00-615-050-A ** ON A/C NOT FOR ALL
A. Cleaning of the Contaminated Area
   (1) In the AFT cargo compartment, clean the contaminated area at waste holding tank and or the area of the potable water tank (Ref. AMM TASK 51-78-00-615-001).
Subtask 38-31-00-670-050-A ** ON A/C NOT FOR ALL
B. Disinfection of the AFT Cargo Compartment
   (1) Use a GUN - SPRAY and apply Disinfectant-Aircraft General - - (Material No.11AAA2) in the AFT cargo compartment, the area of the waste holding tank and the area of the potable water tank (Ref. AMM TASK 12-21-12-670-001).
   (2) After the disinfection, dry the area and the compartment floor with hot air at 40 DEG.C (104.00 DEG.F).
Subtask 38-31-00-615-050-C ** ON A/C NOT FOR ALL
C. Cleaning of the Contaminated Area
   (1) In the AFT cargo compartment, clean the contaminated area of the waste holding tank (Ref. AMM TASK 51-78-00-615-001).
Subtask 38-31-00-670-050-C ** ON A/C NOT FOR ALL
D. Disinfection of the AFT Cargo Compartment
   (1) Use a GUN - SPRAY and apply Disinfectant-Aircraft General - - (Material No.11AAA2) in the AFT cargo compartment and the area of the waste holding tank (Ref. AMM TASK 12-21-12-670-001).
   (2) After the disinfection, dry the area and the compartment floor with hot air at 40 DEG.C (104.00 DEG.F).
Subtask 38-31-00-210-063-A
E. Inspection Check
   (1) Do a check of the insulation blankets for signs of contamination.
   (2) If the blankets are contaminated and in a bad condition, you must replace them.
Subtask 38-31-00-110-052-A
F. Clean the aircraft structure with Non Aqueous Cleaner-General - - (Material No.08BAA9) and follow the recommendations as for SRM 517815.
Subtask 38-31-00-210-064-A
G. Inspection Check
   (1) Do an inspection of the outflow valve.
     (a) If there is contamination, replace the outflow valve (Ref. AMM TASK 21-31-51-000-001) and (Ref. AMM TASK 21-31-51-400-001).
   (2) Do a check of the vacuum generator.
     (a) If there is too much contamination:
   (3) Do a check of the water separator.
     (a) If there is too much contamination:
   (4) Do a check of the LLT.
     (a) If there is too much contamination:
   (5) Do a check of the LLS.
     (a) If there is too much contamination:
5. Close-up
Subtask 38-31-00-410-096-A
A. Close Access
   (1) Make sure that the work area is clean and clear of tools and other items.
   (2) Install the insulation blankets.
   (3) Install the waste holding tank (Ref. AMM TASK 38-31-61-400-001).
   (4) Install the access panels 161DW and 162DW.
Subtask 38-31-00-942-070-A
B. Remove the WARNING NOTICE(S).
Subtask 38-31-00-862-077-A
C. De-energize the ground service network
(Ref. AMM TASK 24-42-00-862-001).
[Rev.10 from 2021] 2026.04.01 01:20:05 UTC