Cleaning of the Vacuum Waste Lines with Chemical Cleaning Agent and Crushed Ice
TASK 38-31-00-100-010-A
Cleaning of the Vacuum Waste Lines with Chemical Cleaning Agent and Crushed Ice
Self explanatory
2. Job Set-up Information
A. Consumable Materials
B. Referenced Information
3. Job Set-up
Subtask 38-31-00-861-074-A Subtask 38-31-00-865-114-A
Subtask 38-31-00-100-058-A
(2) Put 1 l (0.26 USgal) of Aqueous Cleaner-Toilet System Preventive De-scaling - (Material No.08AHB1) or a weak vinegar solution (0.5 l (0.13 USgal) of vinegar (10% acetic acid solution) and 0.5 l (0.13 USgal) of water) into the toilet bowl.
(3) Let the cleaning agent stay in the toilet bowl for 10 minutes.
(4) Put 2 l (0.53 USgal) of crushed ice into the toilet assembly and immediately flush the toilet assembly 2 times.
(6) After 30 minutes, flush the toilet assemblies 3 times.
5. Close-up
Subtask 38-31-00-613-069-A Subtask 38-31-00-410-091-A
[Rev.10 from 2021]
2026.04.01 01:20:05 UTC
Cleaning of the Vacuum Waste Lines with Chemical Cleaning Agent and Crushed Ice
WARNING:
BE CAREFUL WHEN YOU USE CONSUMABLE MATERIALS. OBEY THE MATERIAL MANUFACTURER'S INSTRUCTIONS AND YOUR LOCAL REGULATIONS.
1. Reason for the JobSelf explanatory
2. Job Set-up Information
A. Consumable Materials
| REFERENCE | DESIGNATION |
|---|---|
| (Material No.08AHB1) | Aqueous Cleaner-Toilet System Preventive De-scaling - |
| (Material No.14SBA1) | Textile-Lint free Cotton - |
| No specific | crushed ice |
| No specific | vinegar (10% acetic acid solution) |
| No specific | water |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 12-16-38-613-001-A | Servicing of the Toilet System |
| TASK 24-42-00-861-001-A | Energize the Ground Service Network from the External Power |
| TASK 24-42-00-862-001-A | De-energize the Ground Service Network Supplied from the External Power |
| TASK 38-10-00-614-001-A | Pressurization of the Potable Water System from a Ground Air Supply |
Subtask 38-31-00-861-074-A Subtask 38-31-00-865-114-A
B. Make sure that this(these) circuit breaker(s) is(are) closed:
Subtask 38-31-00-860-065-A | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 2001VU | VACU TOIL SYS-VACUUM-SYS | 35MG | A06 |
| ** ON A/C NOT FOR ALL | |||
| 2001VU | VACU TOIL SYS-VACUUM-GEN | 33MG | A08 |
| ** ON A/C NOT FOR ALL | |||
| 2001VU | VACU TOIL SYS-LAV PWR-E | 34MG | A04 |
| ** ON A/C NOT FOR ALL | |||
| 2001VU | VACU TOIL SYS-LAV PWR-D | 39MG | A03 |
| ** ON A/C ALL | |||
| 2001VU | VACU TOIL SYS-LAV PWR-A | 32MG | A01 |
| ** ON A/C NOT FOR ALL | |||
| 2001VU | VACU TOIL SYS-VACU-SYS | 35MG | A06 |
| ** ON A/C NOT FOR ALL | |||
| 2001VU | VACU TOIL SYS-VACU-GEN | 33MG | A08 |
| ** ON A/C NOT FOR ALL | |||
| 2001VU | VACU TOIL SYS-LAV PWR-G | 34MG | A04 |
| 2001VU | VACU TOIL SYS-LAV PWR-F | 39MG | A03 |
| 2001VU | VACU TOIL SYS-LAV PWR-D | 45MG | A02 |
| ** ON A/C NOT FOR ALL | |||
| 2001VU | VACU TOIL SYS-LAV PWR-L | 45MG | A02 |
| ** ON A/C NOT FOR ALL | |||
| 2001VU | VACU TOIL SYS-LAV PWR-L | 23MG | A05 |
| ** ON A/C NOT FOR ALL | |||
| 2001VU | VACU TOIL SYS-LAV PWR-M | 34MG | A04 |
C. Aircraft Maintenance Configuration
(1) Do the servicing of the waste holding tank (Ref. AMM TASK 12-16-38-613-001).
(2) Make sure that the potable water system is pressurized (Ref. AMM TASK 38-10-00-614-001).
Subtask 38-31-00-010-090-A (1) Do the servicing of the waste holding tank (Ref. AMM TASK 12-16-38-613-001).
(2) Make sure that the potable water system is pressurized (Ref. AMM TASK 38-10-00-614-001).
NOTE: TASK 38-10-00-614-003 is an alternative water pressurization procedure to this step. This task is applicable to aircrafts which have an air compressor installed.
D. Get Access
(1) Get access to the lavatories.
4. Procedure(1) Get access to the lavatories.
Subtask 38-31-00-100-058-A
WARNING:
ALWAYS WEAR RUBBER GLOVES, GOGGLES AND PROTECTIVE CLOTHES WHEN YOU DO THIS TASK.
A. Cleaning of the Toilet Waste Lines NOTE: Airbus recommends that you start the procedure in the most forward lavatory.
(1) Flush the toilet assembly. (2) Put 1 l (0.26 USgal) of Aqueous Cleaner-Toilet System Preventive De-scaling - (Material No.08AHB1) or a weak vinegar solution (0.5 l (0.13 USgal) of vinegar (10% acetic acid solution) and 0.5 l (0.13 USgal) of water) into the toilet bowl.
(3) Let the cleaning agent stay in the toilet bowl for 10 minutes.
(4) Put 2 l (0.53 USgal) of crushed ice into the toilet assembly and immediately flush the toilet assembly 2 times.
NOTE: Airbus recommends that you use only the crushed ice and not the ice cubes.
(5) Do this procedure in all the lavatories. (6) After 30 minutes, flush the toilet assemblies 3 times.
NOTE: Airbus recommends that you start the procedure in the most forward lavatory.
Subtask 38-31-00-613-069-A Subtask 38-31-00-410-091-A
B. Close Access
(1) Dry the area around the toilet with Textile-Lint free Cotton - (Material No.14SBA1) .
(2) Make sure that the work area is clean and clear of tools and other items.
(3) Close the lavatory door(s).
Subtask 38-31-00-862-073-A (1) Dry the area around the toilet with Textile-Lint free Cotton - (Material No.14SBA1) .
(2) Make sure that the work area is clean and clear of tools and other items.
(3) Close the lavatory door(s).