W DOC AIRBUS | AMM A320F

Cleaning of the Toilet Waste Lines with Crushed Ice


TASK 38-31-00-100-005-A
Cleaning of the Toilet Waste Lines with Crushed Ice


WARNING: BE CAREFUL WHEN YOU USE CONSUMABLE MATERIALS. OBEY THE MATERIAL MANUFACTURER'S INSTRUCTIONS AND YOUR LOCAL REGULATIONS.
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Consumable Materials
REFERENCE
DESIGNATION
(Material No.11GCA1)
Deodorant-Aircraft Toilets - -
(Material No.14SBA1)
Textile-Lint free Cotton -
No specific
crushed ice
No specific
vinegar (10% acetic acid solution)
 B. Referenced Information
REFERENCE
DESIGNATION
TASK 12-15-38-613-001-A
Fill the Potable Water Tank System (Aircraft Electrical Power Available)
TASK 12-16-38-613-001-A
Servicing of the Toilet System
TASK 24-42-00-861-001-A
Energize the Ground Service Network from the External Power
TASK 24-42-00-862-001-A
De-energize the Ground Service Network Supplied from the External Power
TASK 38-10-00-614-001-A
Pressurization of the Potable Water System from a Ground Air Supply
3. Job Set-up
Subtask 38-31-00-861-063-A
A. Energize the ground service network
(Ref. AMM TASK 24-42-00-861-001).
Subtask 38-31-00-680-051-A
B. Aircraft Maintenance Configuration
   (1) Do the servicing of the waste holding tank (Ref. AMM TASK 12-16-38-613-001).
   (2) Make sure that the potable water system contains water and is pressurized (Ref. AMM TASK 12-15-38-613-001) and (Ref. AMM TASK 38-10-00-614-001).
Subtask 38-31-00-865-094-A
C. Make sure that this(these) circuit breaker(s) is(are) closed:
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
2001VUVACU TOIL SYS-VACUUM-SYS35MGA06
** ON A/C NOT FOR ALL
2001VUVACU TOIL SYS-VACUUM-GEN33MGA08
** ON A/C NOT FOR ALL
2001VUVACU TOIL SYS-LAV PWR-E34MGA04
** ON A/C NOT FOR ALL
2001VUVACU TOIL SYS-LAV PWR-D39MGA03
** ON A/C ALL
2001VUVACU TOIL SYS-LAV PWR-A32MGA01
** ON A/C NOT FOR ALL
2001VUVACU TOIL SYS-VACU-SYS35MGA06
** ON A/C NOT FOR ALL
2001VUVACU TOIL SYS-VACU-GEN33MGA08
** ON A/C NOT FOR ALL
2001VUVACU TOIL SYS-LAV PWR-G34MGA04
2001VUVACU TOIL SYS-LAV PWR-F39MGA03
2001VUVACU TOIL SYS-LAV PWR-D45MGA02
** ON A/C NOT FOR ALL
2001VUVACU TOIL SYS-LAV PWR-L45MGA02
** ON A/C NOT FOR ALL
2001VUVACU TOIL SYS-LAV PWR-L23MGA05
** ON A/C NOT FOR ALL
2001VUVACU TOIL SYS-LAV PWR-M34MGA04
Subtask 38-31-00-010-077-A
D. Get access to the lavatories.
4. Procedure
Subtask 38-31-00-100-051-A
WARNING: ALWAYS WEAR RUBBER GLOVES, GOGGLES AND PROTECTIVE CLOTHES WHEN YOU DO THIS TASK.
A. Clean the Toilet Waste Lines
NOTE: It is necessary to start the procedure at the most forward lavatory.
   (1) Flush the toilet assembly.
   (2) Put 1 l (0.2642 USgal) of vinegar (10% acetic acid solution) and/or Deodorant-Aircraft Toilets - - (Material No.11GCA1) into each toilet bowl.
   (3) Let the toilet bowls soak for 10 minutes.
NOTE: It is important not to ignore the cleaning agent soaking.
   (4) Put 2 l (0.5 USgal) of crushed ice into the toilet assembly and flush the toilet immediately 2 times.
NOTE: The ice must be crushed, ice cubes are not permitted.
   (5) Do the procedure for all of the toilets.
   (6) After 30 minutes flush the toilet assemblies 3 times.
NOTE: It is necessary to start the procedure at the most forward lavatory.
5. Close-up
Subtask 38-31-00-613-062-A
A. Do the servicing of the waste system (Ref. AMM TASK 12-16-38-613-001).
Subtask 38-31-00-410-075-A
B. Close Access
   (1) Dry the area around the toilet with Textile-Lint free Cotton - (Material No.14SBA1) .
   (2) Make sure that the work area is clean and clear of tools and other items.
   (3) Close the lavatory door(s).
Subtask 38-31-00-862-063-A
C. De-energize the ground service network
(Ref. AMM TASK 24-42-00-862-001).
[Rev.10 from 2021] 2026.04.01 01:19:59 UTC