Deactivation of the Vacuum Generator of the Vacuum Toilet System
TASK 38-31-00-040-802-A
Deactivation of the Vacuum Generator of the Vacuum Toilet System
This procedure supplies the data to deactivate the vacuum generator of the vacuum toilet system.
A. Fixtures, Tools, Test and Support Equipment
B. Referenced Information
3. Job Set-up
Subtask 38-31-00-861-092-A
Subtask 38-31-00-865-142-A
Subtask 38-31-00-860-081-A
[Rev.10 from 2021]
2026.04.01 01:19:40 UTC
Deactivation of the Vacuum Generator of the Vacuum Toilet System
FIN: 37MG
1. Reason for the JobThis procedure supplies the data to deactivate the vacuum generator of the vacuum toilet system.
NOTE: This deactivation task is not related to an AFM-CDL/MMEL item.
2. Job Set-up InformationA. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | SAFETY CLIP - CIRCUIT BREAKER |
| No specific | AR | WARNING NOTICE(S) |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-42-00-861-001-A | Energize the Ground Service Network from the External Power |
| TASK 24-42-00-862-001-A | De-energize the Ground Service Network Supplied from the External Power |
Subtask 38-31-00-861-092-A
A. Aircraft Maintenance Configuration
(1) Energize the ground service network
(Ref. AMM TASK 24-42-00-861-001).
4. Procedure(1) Energize the ground service network
(Ref. AMM TASK 24-42-00-861-001).
Subtask 38-31-00-865-142-A
A. Open, safety and tag this(these) circuit breaker(s):
Subtask 38-31-00-941-075-A | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 2001VU | VACU TOIL SYS-VACUUM-GEN | 33MG | A08 |
| ** ON A/C NOT FOR ALL | |||
| 2001VU | VACU TOIL SYS-VACU-GEN | 33MG | A08 |
B. Safety Precautions
(1) In the cabin, on circuit breaker panel 2001VU, put a WARNING NOTICE(S) in position to tell persons not to close circuit breaker 33MG.
(2) Close and lock all lavatory doors from the outer side.
(3) Put a notice on all lavatory doors to tell persons that they only can use the toilets at an aircraft altitude of 16000 ft. and more.
5. Close-up(1) In the cabin, on circuit breaker panel 2001VU, put a WARNING NOTICE(S) in position to tell persons not to close circuit breaker 33MG.
(2) Close and lock all lavatory doors from the outer side.
(3) Put a notice on all lavatory doors to tell persons that they only can use the toilets at an aircraft altitude of 16000 ft. and more.
NOTE: At an aircraft altitude of 16000 ft. and more, the difference pressure between the cabin and the atmosphere gives a sufficient vacuum to operate the toilet flush.
Subtask 38-31-00-860-081-A
A. Aircraft Maintenance Configuration
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Make an entry in the logbook.
(3) De-energize the ground service network
(Ref. AMM TASK 24-42-00-862-001).
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Make an entry in the logbook.
(3) De-energize the ground service network
(Ref. AMM TASK 24-42-00-862-001).