Installation of the Control Handle
TASK 38-14-48-400-002-A
Installation of the Control Handle
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Consumable Materials
C. Work Zones and Access Panels
D. Expendable Parts
E. Referenced Information
3. Job Set-up
Subtask 38-14-48-860-051-A ** ON A/C NOT FOR ALL
Subtask 38-14-48-560-051-A ** ON A/C NOT FOR ALL
Subtask 38-14-48-613-051-A ** ON A/C NOT FOR ALL Subtask 38-14-48-410-053-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.02 06:25:45 UTC
Installation of the Control Handle
WARNING:
BE CAREFUL WHEN YOU USE CONSUMABLE MATERIALS. OBEY THE MATERIAL MANUFACTURER'S INSTRUCTIONS AND YOUR LOCAL REGULATIONS.
1. Reason for the JobSelf explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | ACCESS PLATFORM 1M(3 FT) |
| No specific | AR | ACCESS PLATFORM 2M (6 FT) |
| No specific | AR | ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE |
| No specific | AR | ACCESS PLATFORM 5M (16 FT)- ADJUSTABLE |
| No specific | AR | WARNING NOTICE(S) |
| REFERENCE | DESIGNATION |
|---|---|
| (Material No.03HBD9) | Synthetic Ester base Grease-General Purpose Low Temp - |
| (Material No.08BBB1) | Non Aqueous Cleaner-- Petroleum Based - |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 132PW, 171AL, 192NB, 825, 832, 842 |
| FIG.ITEM | DESIGNATION | IPC-CSN |
|---|---|---|
| 9 | SILICONE SEAL | AIPC 38-14-02-05-095 |
| 9 | SILICONE SEAL | AIPC 38-14-82-05-070 |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 12-15-38-613-001-A | Fill the Potable Water Tank System (Aircraft Electrical Power Available) |
| TASK 24-42-00-861-001-A | Energize the Ground Service Network from the External Power |
| TASK 24-42-00-862-001-A | De-energize the Ground Service Network Supplied from the External Power |
| TASK 25-54-12-000-001-A | Removal of the Forward Cargo-Compartment Partition |
| TASK 25-54-12-400-001-A | Installation of the Forward Cargo-Compartment Partition |
| TASK 38-10-00-614-001-A | Pressurization of the Potable Water System from a Ground Air Supply |
| TASK 38-10-00-614-002-A | Depressurization of the Potable Water System |
| TASK 52-10-00-010-001-A | Opening of the Passenger/Crew Door |
| TASK 52-10-00-410-001-A | Closing of the Passenger/Crew Door |
| TASK 52-30-00-860-001-A | Open the FWD or Aft Cargo-Compartment Door with the Yellow Electric Pump |
| TASK 52-30-00-860-002-A | Close the FWD or Aft Cargo-Compartment Door with the Yellow Electric Pump |
| TASK 06-41-53-00 | FUSELAGE-DESCRIPTION AND OPERATION |
Subtask 38-14-48-860-051-A ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
(1) Make sure that the ground service network is energized (Ref. AMM TASK 24-42-00-861-001).
(2) Make sure that the system potable water is depressurized (Ref. AMM TASK 38-10-00-614-002).
Subtask 38-14-48-010-055-A ** ON A/C NOT FOR ALL (1) Make sure that the ground service network is energized (Ref. AMM TASK 24-42-00-861-001).
(2) Make sure that the system potable water is depressurized (Ref. AMM TASK 38-10-00-614-002).
B. Get Access
(1) Make sure that the ACCESS PLATFORM 5M (16 FT)- ADJUSTABLE is in position in front of the applicable passenger/crew door 832 or 842.
(2) Make sure that the passenger/crew door 832 or 842 is open (Ref. AMM TASK 52-10-00-010-001).
(3) Make sure that the ACCESS PLATFORM 1M(3 FT) is in position at the drain and overflow panel 192NB.
(4) Make sure that the drain and overflow panel 192NB is open.
(5) Make sure that the WARNING NOTICE(S) is in position in the drain and overflow panel.
(6) Make sure that the ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE is in position at the service panel 2023VU.
(7) Make sure that the access door 171AL of the service panel 2023VU is open.
(8) Make sure that the WARNING NOTICE(S) is in position in the service panel 2023VU.
(9) Make sure that the ACCESS PLATFORM 2M (6 FT) is in position at the door 825.
(10) Make sure that the FWD cargo-compartment door 825 is open (Ref. AMM TASK 52-30-00-860-001).
(11) Make sure that the CARGO COMPT LIGHT switch 6LU is at ON.
(12) Make sure that the forward cargo-compartment partition panel 132PW is removed (Ref. AMM TASK 25-54-12-000-001) and (Ref. AMM D/O 06-41-53-00).
Subtask 38-14-48-865-054-A ** ON A/C NOT FOR ALL (1) Make sure that the ACCESS PLATFORM 5M (16 FT)- ADJUSTABLE is in position in front of the applicable passenger/crew door 832 or 842.
(2) Make sure that the passenger/crew door 832 or 842 is open (Ref. AMM TASK 52-10-00-010-001).
(3) Make sure that the ACCESS PLATFORM 1M(3 FT) is in position at the drain and overflow panel 192NB.
(4) Make sure that the drain and overflow panel 192NB is open.
(5) Make sure that the WARNING NOTICE(S) is in position in the drain and overflow panel.
(6) Make sure that the ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE is in position at the service panel 2023VU.
(7) Make sure that the access door 171AL of the service panel 2023VU is open.
(8) Make sure that the WARNING NOTICE(S) is in position in the service panel 2023VU.
(9) Make sure that the ACCESS PLATFORM 2M (6 FT) is in position at the door 825.
(10) Make sure that the FWD cargo-compartment door 825 is open (Ref. AMM TASK 52-30-00-860-001).
(11) Make sure that the CARGO COMPT LIGHT switch 6LU is at ON.
(12) Make sure that the forward cargo-compartment partition panel 132PW is removed (Ref. AMM TASK 25-54-12-000-001) and (Ref. AMM D/O 06-41-53-00).
C. Make sure that this(these) circuit breaker(s) is(are) open, safetied and tagged:
4. Procedure| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 2001VU | WATER SYS-DRAIN | 1MP | B05 |
| ** ON A/C NOT FOR ALL | |||
| 2001VU | WATER-SYS-DRAIN | 1MP | B05 |
Subtask 38-14-48-560-051-A ** ON A/C NOT FOR ALL
A. Preparation for Installation
(1) Clean the lever (10), the bush (8), the bearing assy (7) and the handle (6) with Non Aqueous Cleaner-- Petroleum Based - (Material No.08BBB1) .
(2) Apply Synthetic Ester base Grease-General Purpose Low Temp - (Material No.03HBD9) to the bush (8) and the bearing assy (7).
Subtask 38-14-48-420-051-B ** ON A/C NOT FOR ALL (1) Clean the lever (10), the bush (8), the bearing assy (7) and the handle (6) with Non Aqueous Cleaner-- Petroleum Based - (Material No.08BBB1) .
(2) Apply Synthetic Ester base Grease-General Purpose Low Temp - (Material No.03HBD9) to the bush (8) and the bearing assy (7).
B. Installation of the Control Handle
(1) Do an inspection of the component interfaces and the adjacent area.
(2) Install the new AIPC 38-14-02-05-095 SILICONE SEAL (9) or AIPC 38-14-82-05-070 SILICONE SEAL (9) on the bush (8).
(3) Outside the aircraft, assembly the bush (8), the handle (6), the bolt (5) and hold against the aircraft structure.
(4) Make sure that the overflow handle (drain handle) is in the closed position.
(5) Install the lever (10) and the nut (11).
Subtask 38-14-48-680-052-A ** ON A/C NOT FOR ALL Subtask 38-14-48-865-055-A ** ON A/C NOT FOR ALL (1) Do an inspection of the component interfaces and the adjacent area.
(2) Install the new AIPC 38-14-02-05-095 SILICONE SEAL (9) or AIPC 38-14-82-05-070 SILICONE SEAL (9) on the bush (8).
(3) Outside the aircraft, assembly the bush (8), the handle (6), the bolt (5) and hold against the aircraft structure.
(4) Make sure that the overflow handle (drain handle) is in the closed position.
(5) Install the lever (10) and the nut (11).
D. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
Subtask 38-14-48-720-051-A ** ON A/C NOT FOR ALL | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 2001VU | WATER SYS-DRAIN | 1MP | B05 |
| ** ON A/C NOT FOR ALL | |||
| 2001VU | WATER-SYS-DRAIN | 1MP | B05 |
E. Do this Test
5. Close-up| ACTION | RESULT |
|---|---|
1.At the drain and overflow panel:
| In the potable water system:
|
| In the potable water system:
|
Subtask 38-14-48-613-051-A ** ON A/C NOT FOR ALL Subtask 38-14-48-410-053-A ** ON A/C NOT FOR ALL
B. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the passenger/crew door 832 or 842 (Ref. AMM TASK 52-10-00-410-001).
(3) Close the drain and overflow panel 192NB.
(4) Close the access door 171AL of the service panel 2023VU.
(5) Install the forward cargo-compartment partition panel 132PW (Ref. AMM TASK 25-54-12-400-001) and (Ref. AMM D/O 06-41-53-00)
(6) Set the CARGO COMPT LIGHT switch 6LU to OFF.
(7) Close the FWD cargo-compartment door 825 (Ref. AMM TASK 52-30-00-860-002).
(8) Remove the WARNING NOTICE(S).
(9) Remove the access platform(s).
Subtask 38-14-48-862-051-A ** ON A/C NOT FOR ALL (1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the passenger/crew door 832 or 842 (Ref. AMM TASK 52-10-00-410-001).
(3) Close the drain and overflow panel 192NB.
(4) Close the access door 171AL of the service panel 2023VU.
(5) Install the forward cargo-compartment partition panel 132PW (Ref. AMM TASK 25-54-12-400-001) and (Ref. AMM D/O 06-41-53-00)
(6) Set the CARGO COMPT LIGHT switch 6LU to OFF.
(7) Close the FWD cargo-compartment door 825 (Ref. AMM TASK 52-30-00-860-002).
(8) Remove the WARNING NOTICE(S).
(9) Remove the access platform(s).
Control Handle - Overflow and Drain Valves