Removal of the Drain Valve
TASK 38-14-45-000-001-A
Removal of the Drain Valve
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 38-14-45-861-050-A ** ON A/C NOT FOR ALL Subtask 38-14-45-680-050-A ** ON A/C NOT FOR ALL Subtask 38-14-45-865-050-A ** ON A/C NOT FOR ALL
Subtask 38-14-45-020-052-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.02 06:25:43 UTC
Removal of the Drain Valve
FIN: 14MP ** ON A/C NOT FOR ALL
1. Reason for the JobSelf explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | ACCESS PLATFORM 2M (6 FT) |
| No specific | AR | CAP - BLANKING |
| No specific | AR | PLUG - BLANKING |
| No specific | AR | SAFETY CLIP - CIRCUIT BREAKER |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 132PW, 825 |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 12-24-38-680-001-A | Draining of the Potable Water System (with Electrical Power) |
| TASK 24-42-00-861-001-A | Energize the Ground Service Network from the External Power |
| TASK 25-54-12-000-001-A | Removal of the Forward Cargo-Compartment Partition |
| TASK 52-30-00-860-001-A | Open the FWD or Aft Cargo-Compartment Door with the Yellow Electric Pump |
Subtask 38-14-45-861-050-A ** ON A/C NOT FOR ALL Subtask 38-14-45-680-050-A ** ON A/C NOT FOR ALL Subtask 38-14-45-865-050-A ** ON A/C NOT FOR ALL
C. Open, safety and tag this(these) circuit breaker(s):
Subtask 38-14-45-010-050-A ** ON A/C NOT FOR ALL | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 2000VU | WATER SYSTEM-QANT-IND | 1MA | B01 |
| ** ON A/C NOT FOR ALL | |||
| 2001VU | WATER SYS-DRAIN | 1MP | B05 |
| ** ON A/C NOT FOR ALL | |||
| 2001VU | WATER-SYS-DRAIN | 1MP | B05 |
D. Get Access
(1) Put an ACCESS PLATFORM 2M (6 FT) in position at the FWD cargo-compartment door 825.
(2) Open FWD cargo-compartment door 825 (Ref. AMM TASK 52-30-00-860-001).
(3) Set CARGO COMPT LIGHT switch 6LU to ON position.
(4) Remove access panel 132PW (Ref. AMM TASK 25-54-12-000-001).
(5) Open the insulation sleeve (12).
4. Procedure(1) Put an ACCESS PLATFORM 2M (6 FT) in position at the FWD cargo-compartment door 825.
(2) Open FWD cargo-compartment door 825 (Ref. AMM TASK 52-30-00-860-001).
(3) Set CARGO COMPT LIGHT switch 6LU to ON position.
(4) Remove access panel 132PW (Ref. AMM TASK 25-54-12-000-001).
(5) Open the insulation sleeve (12).
Subtask 38-14-45-020-052-A ** ON A/C NOT FOR ALL
A. Removal of the Drain Valve Assembly
(2) Put the CAP-BLANKING on each disconnected electrical connector and receptacle.
(3) Disconnect the hose (2) and the pipe (5).
(4) Remove and discard the cotter pin (11) and remove the washer (10).
(5) Remove the pin (9) and disconnect the linkage (8).
(6) Remove the bolts (4) and the washers (3).
(7) Remove the drain valve assembly (6) and the spacers (1).
(8) Put the PLUG-BLANKING in each disconnected line end.
(9) If necessary, remove the insulation sleeve (12).
CAUTION:
MAKE SURE THAT THE ELECTRICAL CONNECTOR IS CLEAN BEFORE YOU DISCONNECT IT. DIRTY ELECTRICAL CONNECTORS CAN CAUSE THRUST REVERSER PROBLEMS.
(1) Disconnect the electrical connector (7) from the drain valve assembly (6). (2) Put the CAP-BLANKING on each disconnected electrical connector and receptacle.
(3) Disconnect the hose (2) and the pipe (5).
(4) Remove and discard the cotter pin (11) and remove the washer (10).
(5) Remove the pin (9) and disconnect the linkage (8).
(6) Remove the bolts (4) and the washers (3).
(7) Remove the drain valve assembly (6) and the spacers (1).
(8) Put the PLUG-BLANKING in each disconnected line end.
(9) If necessary, remove the insulation sleeve (12).
Drain Valve (14MP)