Installation of the Motorized Fill/Overflow-Drain Valve


TASK 38-14-43-400-001-A
Installation of the Motorized Fill/Overflow-Drain Valve


FIN: 8MA ** ON A/C NOT FOR ALL
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
161DW, 162DW
 B. Expendable Parts
FIG.ITEM
DESIGNATION
IPC-CSN
6
COTTER PIN
AIPC 38-14-47-01-190
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 12-15-38-613-001-A
Fill the Potable Water Tank System (Aircraft Electrical Power Available)
TASK 12-24-38-680-001-A
Draining of the Potable Water System (with Electrical Power)
TASK 20-28-00-912-802-A
Electrical Bonding - General Maintenance Procedure
TASK 24-42-00-861-001-A
Energize the Ground Service Network from the External Power
TASK 24-42-00-862-001-A
De-energize the Ground Service Network Supplied from the External Power
TASK 38-10-00-614-001-A
Pressurization of the Potable Water System from a Ground Air Supply
TASK 38-14-00-710-001-A
Operational Test of the Potable Water Drain-System
TASK 52-30-00-860-002-A
Close the FWD or Aft Cargo-Compartment Door with the Yellow Electric Pump
3. Job Set-up
Subtask 38-14-43-860-051-A ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
   (1) Make sure that the ground service network is energized from the external power (Ref. AMM TASK 24-42-00-861-001).
   (2) Make sure that the potable water tank is drained (Ref. AMM TASK 12-24-38-680-001).
Subtask 38-14-43-865-052-A ** ON A/C NOT FOR ALL
B. Make sure that this(these) circuit breaker(s) is(are) open, safetied and tagged:
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
2001VUWATER SYS-QUANT-IND1MAB06
2001VUWATER SYS-DRAIN1MPB05
4. Procedure
Subtask 38-14-43-420-051-C ** ON A/C NOT FOR ALL
A. Installation of the Motorized Fill/Overflow-Drain Valve 8MA
   (1) Remove the blanking plugs and the blanking caps.
   (2) Put the motorized fill/overflow-drain valve 8MA (18) in its installation position.
   (3) Install the bolts (16), the washers (17), the washers (4) and the nuts (5).
   (4) Install the bonding strap (12):
     (a) Put the bonding strap (12) in its installation position.
     (b) Install the screw (13) and the nut (11).
     (c) Protect the bonded connection (Ref. AMM TASK 20-28-00-912-802).
   (5) Install the control cable (8):
     (a) Put the control cable (8) in its installation position.
     (b) Install the pin (9) the washers (10) and (7).
     (c) Install the new AIPC 38-14-47-01-190 COTTER PIN (6).
   (6) Install the distribution lines:
     (a) Put the overflow lines in their installation positions and connect the connections (1) and (15).
     (b) Put the fill/drain lines in their installation positions and connect the connections (2) and (14).
   (7) Make sure that all the electrical connections are clean and in the correct condition.
   (8) Connect the electrical connector 8MA-A (3) to the fill/overflow-drain valve 8MA (18).
Subtask 38-14-43-860-050-A ** ON A/C NOT FOR ALL
B. Preparation for Test
   (1) Fill the potable water system with water (
Ref. AMM TASK 12-15-38-613-001).
   (2) Pressurize the potable water system (Ref. AMM TASK 38-10-00-614-001).
   (3) Examine the motorized fill/overflow-drain valve 8MA for leaks.
Subtask 38-14-43-865-051-A ** ON A/C NOT FOR ALL
C. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
2001VUWATER SYS-QUANT-IND1MAB06
2001VUWATER SYS-DRAIN1MPB05
Subtask 38-14-43-710-050-A ** ON A/C NOT FOR ALL
D. Do the operational test of the motorized fill/overflow-drain valve 8MA (Ref. AMM TASK 38-14-00-710-001).
5. Close-up
Subtask 38-14-43-410-050-A ** ON A/C NOT FOR ALL
A. Close Access
   (1) Make sure that the work area is clean and clear of tools and other items.
   (2) Close the access panels 161DW 162DW.
   (3) Close the AFT cargo-compartment door (Ref. AMM TASK 52-30-00-860-002).
   (4) Remove the access platform(s).
Subtask 38-14-43-862-050-A ** ON A/C NOT FOR ALL
B. De-energize the ground service network
(Ref. AMM TASK 24-42-00-862-001).
[Rev.10 from 2021] 2026.04.02 06:25:43 UTC