Removal of the Motorized Fill/Overflow-Drain Valve
TASK 38-14-43-000-001-A
Removal of the Motorized Fill/Overflow-Drain Valve
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 38-14-43-861-050-A ** ON A/C NOT FOR ALL Subtask 38-14-43-680-050-A ** ON A/C NOT FOR ALL Subtask 38-14-43-865-050-A ** ON A/C NOT FOR ALL
Subtask 38-14-43-020-050-B ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.02 06:25:43 UTC
Removal of the Motorized Fill/Overflow-Drain Valve
FIN: 8MA ** ON A/C NOT FOR ALL
1. Reason for the JobSelf explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE |
| No specific | AR | CAP - BLANKING |
| No specific | AR | PLUG - BLANKING |
| No specific | AR | SAFETY CLIP - CIRCUIT BREAKER |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 161DW, 162DW |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 12-24-38-680-001-A | Draining of the Potable Water System (with Electrical Power) |
| TASK 24-42-00-861-001-A | Energize the Ground Service Network from the External Power |
| TASK 52-30-00-860-001-A | Open the FWD or Aft Cargo-Compartment Door with the Yellow Electric Pump |
Subtask 38-14-43-861-050-A ** ON A/C NOT FOR ALL Subtask 38-14-43-680-050-A ** ON A/C NOT FOR ALL Subtask 38-14-43-865-050-A ** ON A/C NOT FOR ALL
C. Open, safety and tag this(these) circuit breaker(s):
Subtask 38-14-43-010-050-A ** ON A/C NOT FOR ALL | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 2001VU | WATER SYS-QUANT-IND | 1MA | B06 |
| 2001VU | WATER SYS-DRAIN | 1MP | B05 |
D. Get Access
(1) Put the ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE in position at the AFT cargo-compartment door.
(2) Open the AFT cargo-compartment door (Ref. AMM TASK 52-30-00-860-001).
(3) Open the access panels 161DW 162DW.
4. Procedure(1) Put the ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE in position at the AFT cargo-compartment door.
(2) Open the AFT cargo-compartment door (Ref. AMM TASK 52-30-00-860-001).
(3) Open the access panels 161DW 162DW.
Subtask 38-14-43-020-050-B ** ON A/C NOT FOR ALL
A. Removal of the Motorized Fill/Overflow-Drain Valve 8MA
(1) Disconnect the electrical connector 8MA-A (3).
(2) Put the CAP-BLANKING on each disconnected electrical connector and receptacle.
(3) Disconnect the distribution lines.
(a) Disconnect the overflow line connectors (1) and (15).
(b) Disconnect the fill/drain line connectors (2) and (14).
(4) Put the PLUG-BLANKING in each disconnected line end.
(5) Removal of the control cable.
(a) Remove and discard the cotter pin (6).
(b) Remove the pin (9) the washers (10) and the washer (7).
(c) Remove the control cable (8) from the lever of the motorized fill/overflow-drain valve 8MA (18).
(6) Removal of the bonding strap.
(a) Remove the nut (11) and the screw (13).
(b) Remove the bonding strap (12).
(7) Remove the bolts (16), the washers (17), the washers (4) and the nuts (5).
(8) Remove the fill/overflow-drain valve 8MA (18).
(1) Disconnect the electrical connector 8MA-A (3).
(2) Put the CAP-BLANKING on each disconnected electrical connector and receptacle.
(3) Disconnect the distribution lines.
(a) Disconnect the overflow line connectors (1) and (15).
(b) Disconnect the fill/drain line connectors (2) and (14).
(4) Put the PLUG-BLANKING in each disconnected line end.
(5) Removal of the control cable.
(a) Remove and discard the cotter pin (6).
(b) Remove the pin (9) the washers (10) and the washer (7).
(c) Remove the control cable (8) from the lever of the motorized fill/overflow-drain valve 8MA (18).
(6) Removal of the bonding strap.
(a) Remove the nut (11) and the screw (13).
(b) Remove the bonding strap (12).
(7) Remove the bolts (16), the washers (17), the washers (4) and the nuts (5).
(8) Remove the fill/overflow-drain valve 8MA (18).
Motorized Fill/Overflow-Drain Valve