Removal of the Fill - Condition Limit - Switch
TASK 38-14-19-000-001-A
Removal of the Fill - Condition Limit - Switch
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 38-14-19-861-050-A ** ON A/C NOT FOR ALL Subtask 38-14-19-010-050-A ** ON A/C NOT FOR ALL
Subtask 38-14-19-020-050-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.02 06:25:43 UTC
Removal of the Fill - Condition Limit - Switch
NOTE: The Fill-Condition Limit-Switch 5MP is refered to in the subsequent procedure as the Limit Switch 5MP.
FIN: 5MP ** ON A/C NOT FOR ALL
1. Reason for the JobSelf explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | ACCESS PLATFORM 2M (6 FT) |
| No specific | 1 | ACCESS PLATFORM 3M (10 FT) |
| No specific | AR | CAP - BLANKING |
| No specific | AR | SAFETY CLIP - CIRCUIT BREAKER |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 161DW |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-42-00-861-001-A | Energize the Ground Service Network from the External Power |
| TASK 52-30-00-860-001-A | Open the FWD or Aft Cargo-Compartment Door with the Yellow Electric Pump |
Subtask 38-14-19-861-050-A ** ON A/C NOT FOR ALL Subtask 38-14-19-010-050-A ** ON A/C NOT FOR ALL
B. Get Access
(1) Put the ACCESS PLATFORM 3M (10 FT) in position at the access door 171AL of the potable water-service panel.
(2) Open the AFT cargo compartment door (Ref. AMM TASK 52-30-00-860-001).
(3) Put the ACCESS PLATFORM 2M (6 FT) in position at the AFT cargo compartment door.
(4) In the AFT cargo compartment, on the control panel 5024VE set the light switch 30LU to the ON position.
(5) Remove the access panel 161DW.
(6) Open the access door 171AL.
Subtask 38-14-19-865-050-A ** ON A/C NOT FOR ALL (1) Put the ACCESS PLATFORM 3M (10 FT) in position at the access door 171AL of the potable water-service panel.
(2) Open the AFT cargo compartment door (Ref. AMM TASK 52-30-00-860-001).
(3) Put the ACCESS PLATFORM 2M (6 FT) in position at the AFT cargo compartment door.
(4) In the AFT cargo compartment, on the control panel 5024VE set the light switch 30LU to the ON position.
(5) Remove the access panel 161DW.
(6) Open the access door 171AL.
C. Open, safety and tag this(these) circuit breaker(s):
4. Procedure| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 2000VU | WATER SYSTEM-QANT-IND | 1MA | B01 |
| ** ON A/C NOT FOR ALL | |||
| 2001VU | WATER SYS-DRAIN | 1MP | B05 |
| ** ON A/C NOT FOR ALL | |||
| 2001VU | WATER-SYS-DRAIN | 1MP | B05 |
Subtask 38-14-19-020-050-A ** ON A/C NOT FOR ALL
A. Removal of the Limit Switch 5MP
(1) Disconnect the electrical connector 5MP-A (6).
(2) Put the CAP-BLANKING on each disconnected electrical connector and receptacle.
(3) Remove and discard the lockwire from the nut (1).
(4) Remove the nut (1), the washer (2) and the limit switch 5MP (5) and the O-ring (4).
(1) Disconnect the electrical connector 5MP-A (6).
(2) Put the CAP-BLANKING on each disconnected electrical connector and receptacle.
(3) Remove and discard the lockwire from the nut (1).
(4) Remove the nut (1), the washer (2) and the limit switch 5MP (5) and the O-ring (4).
Fill Condition Limit Switch