W DOC AIRBUS | AMM A320F

Removal of the Fill - Condition Limit - Switch


TASK 38-14-19-000-001-A
Removal of the Fill - Condition Limit - Switch


NOTE: The Fill-Condition Limit-Switch 5MP is refered to in the subsequent procedure as the Limit Switch 5MP.
FIN: 5MP ** ON A/C NOT FOR ALL
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
1
ACCESS PLATFORM 2M (6 FT)
No specific
1
ACCESS PLATFORM 3M (10 FT)
No specific
AR
CAP - BLANKING
No specific
AR
SAFETY CLIP - CIRCUIT BREAKER
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
161DW
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 24-42-00-861-001-A
Energize the Ground Service Network from the External Power
TASK 52-30-00-860-001-A
Open the FWD or Aft Cargo-Compartment Door with the Yellow Electric Pump
3. Job Set-up
Subtask 38-14-19-861-050-A ** ON A/C NOT FOR ALL
A. Energize the ground service network
(Ref. AMM TASK 24-42-00-861-001)
Subtask 38-14-19-010-050-A ** ON A/C NOT FOR ALL
B. Get Access
   (1) Put the ACCESS PLATFORM 3M (10 FT) in position at the access door 171AL of the potable water-service panel.
   (2) Open the AFT cargo compartment door (Ref. AMM TASK 52-30-00-860-001).
   (3) Put the ACCESS PLATFORM 2M (6 FT) in position at the AFT cargo compartment door.
   (4) In the AFT cargo compartment, on the control panel 5024VE set the light switch 30LU to the ON position.
   (5) Remove the access panel 161DW.
   (6) Open the access door 171AL.
Subtask 38-14-19-865-050-A ** ON A/C NOT FOR ALL
C. Open, safety and tag this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
2000VUWATER SYSTEM-QANT-IND1MAB01
** ON A/C NOT FOR ALL
2001VUWATER SYS-DRAIN1MPB05
** ON A/C NOT FOR ALL
2001VUWATER-SYS-DRAIN1MPB05
4. Procedure
Subtask 38-14-19-020-050-A ** ON A/C NOT FOR ALL
A. Removal of the Limit Switch 5MP
F Fill Condition Limit Switch ** ON A/C NOT FOR ALL
   (1) Disconnect the electrical connector 5MP-A (6).
   (2) Put the CAP-BLANKING on each disconnected electrical connector and receptacle.
   (3) Remove and discard the lockwire from the nut (1).
   (4) Remove the nut (1), the washer (2) and the limit switch 5MP (5) and the O-ring (4).