Removal of the Drain Limit Switch
TASK 38-14-17-000-001-A
Removal of the Drain Limit Switch
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 38-14-17-861-050-A Subtask 38-14-17-010-050-A
Subtask 38-14-17-020-050-A
[Rev.10 from 2021]
2026.04.02 06:25:43 UTC
Removal of the Drain Limit Switch
FIN: 3MP
1. Reason for the JobSelf explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | ACCESS PLATFORM 2M (6 FT) |
| No specific | 1 | ACCESS PLATFORM 3M (10 FT) |
| No specific | AR | CAP - BLANKING |
| No specific | AR | SAFETY CLIP - CIRCUIT BREAKER |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 161DW |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-42-00-861-001-A | Energize the Ground Service Network from the External Power |
| TASK 52-30-00-860-001-A | Open the FWD or Aft Cargo-Compartment Door with the Yellow Electric Pump |
Subtask 38-14-17-861-050-A Subtask 38-14-17-010-050-A
B. Get Access
(1) Put the ACCESS PLATFORM 3M (10 FT) in position at the potable water-service panel.
(2) Open the AFT cargo compartment door (Ref. AMM TASK 52-30-00-860-001).
(3) Put the ACCESS PLATFORM 2M (6 FT) in position at the AFT cargo compartment door.
(4) In the AFT cargo compartment, on the control panel 5024VE set the light switch 30LU to the ON position.
(5) Remove the access panel 161DW.
(6) Open the access door 171AL of the potable water-service panel.
Subtask 38-14-17-865-050-A (1) Put the ACCESS PLATFORM 3M (10 FT) in position at the potable water-service panel.
(2) Open the AFT cargo compartment door (Ref. AMM TASK 52-30-00-860-001).
(3) Put the ACCESS PLATFORM 2M (6 FT) in position at the AFT cargo compartment door.
(4) In the AFT cargo compartment, on the control panel 5024VE set the light switch 30LU to the ON position.
(5) Remove the access panel 161DW.
(6) Open the access door 171AL of the potable water-service panel.
C. Open, safety and tag this(these) circuit breaker(s):
4. Procedure| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 2000VU | WATER SYSTEM-QANT-IND | 1MA | B01 |
| ** ON A/C NOT FOR ALL | |||
| 2001VU | WATER SYS-QUANT-IND | 1MA | B06 |
| ** ON A/C NOT FOR ALL | |||
| 2001VU | WATER SYS-DRAIN | 1MP | B05 |
| ** ON A/C NOT FOR ALL | |||
| 2001VU | WATER-SYS-DRAIN | 1MP | B05 |
Subtask 38-14-17-020-050-A
A. Removal of the Drain Limit Switch 3MP
(1) Disconnect the electrical connector 3MP-A (5).
(2) Put the CAP-BLANKING on each disconnected electrical connector and receptacle.
(4) Remove the nut (1), the washer (2) and the drain limit switch 3MP (4).
(1) Disconnect the electrical connector 3MP-A (5).
(2) Put the CAP-BLANKING on each disconnected electrical connector and receptacle.
WARNING:
USE GOGGLES AND GLOVES WHEN YOU REMOVE OR INSTALL LOCKWIRE. EACH TIME YOU CUT LOCKWIRE, REMOVE AND DISCARD IT IMMEDIATELY. LOOSE LOCKWIRE CAN CUT YOU OR MAKE YOU BLIND, AND/OR CAN CAUSE DAMAGE.
(3) Remove and discard the lockwire from the nut (1). (4) Remove the nut (1), the washer (2) and the drain limit switch 3MP (4).
Drain Limit Switch