Adjustment of the Drain Limit Switch
TASK 38-14-00-820-002-A
Adjustment of the Drain Limit Switch
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 38-14-00-861-058-A ** ON A/C NOT FOR ALL Subtask 38-14-00-010-065-A ** ON A/C NOT FOR ALL
Subtask 38-14-00-820-051-A ** ON A/C NOT FOR ALL
Subtask 38-14-00-613-053-A ** ON A/C NOT FOR ALL Subtask 38-14-00-410-063-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.02 06:25:43 UTC
Adjustment of the Drain Limit Switch
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE |
| No specific | AR | SAFETY CLIP - CIRCUIT BREAKER |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 160 | BULK CARGO COMPARTMENT AFT BULKHEAD OF AFT CARGO COMPARTMENT TO AFT BULKHEAD OF BULK CARGO COMPARTMENT |
| 170 | AFT CAB U/FLOOR COMPT AFT BHD OF BULK |
| 161DW, 171AL |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 12-16-38-613-001-A | Servicing of the Toilet System |
| TASK 12-24-38-680-001-A | Draining of the Potable Water System (with Electrical Power) |
| TASK 24-42-00-861-001-A | Energize the Ground Service Network from the External Power |
| TASK 24-42-00-862-001-A | De-energize the Ground Service Network Supplied from the External Power |
| TASK 25-55-12-000-001-A | Removal of the Aft Cargo-Compartment Partition at FR65 |
| TASK 25-55-12-400-001-A | Installation of the Aft Cargo-Compartment Partition at FR65 |
| TASK 52-30-00-860-001-A | Open the FWD or Aft Cargo-Compartment Door with the Yellow Electric Pump |
| TASK 52-30-00-860-002-A | Close the FWD or Aft Cargo-Compartment Door with the Yellow Electric Pump |
| TASK 52-30-00-860-003-A | Open the FWD or Aft Cargo-Compartment Door with the Hand Pump |
| TASK 52-30-00-860-004-A | Close the FWD or Aft Cargo-Compartment Door with the Hand Pump |
Subtask 38-14-00-861-058-A ** ON A/C NOT FOR ALL Subtask 38-14-00-010-065-A ** ON A/C NOT FOR ALL
B. Get Access
(1) Open the aft cargo-compartment door (Ref. AMM TASK 52-30-00-860-001) or (Ref. AMM TASK 52-30-00-860-003).
(2) Put the ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position below the aft cargo-compartment door.
(3) Set CARGO COMPT LIGHT switch 8LU to ON.
(4) Remove partition 161DW (Ref. AMM TASK 25-55-12-000-001).
(5) Put the ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position below the Potable Water Service Panel (PWSP).
(6) Open access door 171AL of the PWSP.
Subtask 38-14-00-680-057-A ** ON A/C NOT FOR ALL Subtask 38-14-00-865-080-A ** ON A/C NOT FOR ALL (1) Open the aft cargo-compartment door (Ref. AMM TASK 52-30-00-860-001) or (Ref. AMM TASK 52-30-00-860-003).
(2) Put the ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position below the aft cargo-compartment door.
(3) Set CARGO COMPT LIGHT switch 8LU to ON.
(4) Remove partition 161DW (Ref. AMM TASK 25-55-12-000-001).
(5) Put the ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position below the Potable Water Service Panel (PWSP).
(6) Open access door 171AL of the PWSP.
D. Open, safety and tag this(these) circuit breaker(s):
4. Procedure| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 2001VU | WATER SYS-QUANT-IND | 1MA | B06 |
| 2001VU | WATER SYS-DRAIN | 1MP | B05 |
Subtask 38-14-00-820-051-A ** ON A/C NOT FOR ALL
A. Adjustment of the Limit Switch 3MP
(1) Adjust the drain limit switch 3MP.
(a) Turn the fill/drain and overflow handle (3254MM) to the right and pull it out 31.0 +2 mm or -2 mm (1.2205 +0.0787 in. or -0.0787 in.)
DIMENSION A.
(c) Move the switch assembly in the direction of the control cam (1) until you hear a click.
(d) Tighten the bolts (2).
(e) Make sure that the switch 3MP is aligned with the control cam (1).
(f) Release the fill/drain and overflow handle to the Normal position.
(g) Make sure that Dimension B has a minimum clearance of 2.0 +1 mm or -0 mm (0.0787 +0.0394 in. or +0.0000 in.) between the outer end of the switch and the spring (3).
Subtask 38-14-00-865-081-A ** ON A/C NOT FOR ALL (1) Adjust the drain limit switch 3MP.
(a) Turn the fill/drain and overflow handle (3254MM) to the right and pull it out 31.0 +2 mm or -2 mm (1.2205 +0.0787 in. or -0.0787 in.)
DIMENSION A.
NOTE: You must hold the fill/drain and overflow handle in this position to do the adjustment.
(b) Loosen the bolts (2) on the bracket of the switch. (c) Move the switch assembly in the direction of the control cam (1) until you hear a click.
(d) Tighten the bolts (2).
(e) Make sure that the switch 3MP is aligned with the control cam (1).
(f) Release the fill/drain and overflow handle to the Normal position.
(g) Make sure that Dimension B has a minimum clearance of 2.0 +1 mm or -0 mm (0.0787 +0.0394 in. or +0.0000 in.) between the outer end of the switch and the spring (3).
B. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
Subtask 38-14-00-720-051-B ** ON A/C NOT FOR ALL | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 2001VU | WATER SYS-QUANT-IND | 1MA | B06 |
| 2001VU | WATER SYS-DRAIN | 1MP | B05 |
C. Functional Test
(1) Do this test.
5. Close-up(1) Do this test.
| ACTION | RESULT |
|---|---|
1.At the service panel 2023VU:
| In the potable water system:
|
2.At the service panel 2023VU:
| In the potable water system:
|
Subtask 38-14-00-613-053-A ** ON A/C NOT FOR ALL Subtask 38-14-00-410-063-A ** ON A/C NOT FOR ALL
B. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Close access door 171AL of the PWSP.
(3) Install partition 161DW (Ref. AMM TASK 25-55-12-400-001).
(4) Set CARGO COMPT LIGHT switch 8LU to OFF.
(5) Remove the access platform(s).
(6) Close the aft cargo-compartment door (Ref. AMM TASK 52-30-00-860-002) or (Ref. AMM TASK 52-30-00-860-004).
(7) Remove the ground support and maintenance equipment, the special and standard tools and all other items.
Subtask 38-14-00-862-059-A ** ON A/C NOT FOR ALL (1) Make sure that the work area is clean and clear of tools and other items.
(2) Close access door 171AL of the PWSP.
(3) Install partition 161DW (Ref. AMM TASK 25-55-12-400-001).
(4) Set CARGO COMPT LIGHT switch 8LU to OFF.
(5) Remove the access platform(s).
(6) Close the aft cargo-compartment door (Ref. AMM TASK 52-30-00-860-002) or (Ref. AMM TASK 52-30-00-860-004).
(7) Remove the ground support and maintenance equipment, the special and standard tools and all other items.
Drain Limit-Switch 3MP Adjustment