Adjustment of the Limit Switches
TASK 38-14-00-820-001-A
Adjustment of the Limit Switches
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 38-14-00-861-053-A ** ON A/C NOT FOR ALL Subtask 38-14-00-010-058-B ** ON A/C NOT FOR ALL
Subtask 38-14-00-820-050-A ** ON A/C NOT FOR ALL
Subtask 38-14-00-613-052-A ** ON A/C NOT FOR ALL Subtask 38-14-00-410-059-B ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.02 06:25:43 UTC
Adjustment of the Limit Switches
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | ACCESS PLATFORM 2M (6 FT) |
| No specific | 1 | ACCESS PLATFORM 3M (10 FT) |
| No specific | AR | SAFETY CLIP - CIRCUIT BREAKER |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 161DW, 171AL |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 12-16-38-613-001-A | Servicing of the Toilet System |
| TASK 12-24-38-680-001-A | Draining of the Potable Water System (with Electrical Power) |
| TASK 24-42-00-861-001-A | Energize the Ground Service Network from the External Power |
| TASK 24-42-00-862-001-A | De-energize the Ground Service Network Supplied from the External Power |
| TASK 52-30-00-860-002-A | Close the FWD or Aft Cargo-Compartment Door with the Yellow Electric Pump |
Subtask 38-14-00-861-053-A ** ON A/C NOT FOR ALL Subtask 38-14-00-010-058-B ** ON A/C NOT FOR ALL
B. Get Access
(1) Put the warning notices in position to tell persons not to use the toilets.
(2) Put the ACCESS PLATFORM 3M (10 FT) in position at the potable water-service panel 171AL.
(3) Put the ACCESS PLATFORM 2M (6 FT) in position at the AFT cargo compartment door.
(4) Open the AFT cargo compartment door.
(5) Remove the access panel 161DW.
(6) Open the potable water-service panel 171AL.
Subtask 38-14-00-680-054-A ** ON A/C NOT FOR ALL Subtask 38-14-00-865-065-A ** ON A/C NOT FOR ALL (1) Put the warning notices in position to tell persons not to use the toilets.
(2) Put the ACCESS PLATFORM 3M (10 FT) in position at the potable water-service panel 171AL.
(3) Put the ACCESS PLATFORM 2M (6 FT) in position at the AFT cargo compartment door.
(4) Open the AFT cargo compartment door.
(5) Remove the access panel 161DW.
(6) Open the potable water-service panel 171AL.
D. Open, safety and tag this(these) circuit breaker(s):
4. Procedure| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 2000VU | WATER SYSTEM-QANT-IND | 1MA | B01 |
| ** ON A/C NOT FOR ALL | |||
| 2001VU | WATER SYS-DRAIN | 1MP | B05 |
| ** ON A/C NOT FOR ALL | |||
| 2001VU | WATER-SYS-DRAIN | 1MP | B05 |
Subtask 38-14-00-820-050-A ** ON A/C NOT FOR ALL
A. Adjustment of the Limit Switches 3MP and 5MP
(1) Adjust the overflow valve-limit switch 5MP.
(a) Turn the fill/drain handle (3254MM) to the left and pull it out 31.0 +2 mm or -2 mm (1.2205 +0.0787 in. or -0.0787 in.)
Dimension A.
(c) Move the switch assembly in the direction of the control cam (1) until you hear a click.
(d) Tighten the bolts (2).
(e) Make sure that the switch 5MP is aligned with the control cam (1).
(f) Release the control handle to the Normal position.
(g) Make sure that Dimension B has a minimum clearance of 2.0 +1 mm or -0 mm (0.0787 +0.0394 in. or +0.0000 in.) between the outer end of the switch and the spring (3).
(2) Adjust the drain limit switch 3MP.
(a) Turn the fill/drain handle (3254MM) to the right and pull it out 31.0 +2 mm or -2 mm (1.2205 +0.0787 in. or -0.0787 in.)
Dimension A.
(c) Move the switch assembly in the direction of the control cam (1) until you hear a click.
(d) Tighten the bolts (2).
(e) Make sure that the switch 3MP is aligned with the control cam (1).
(f) Release the fill/drain handle to the Normal position.
(g) Make sure that Dimension C has a minimum clearance of 2.0 +1 mm or -0 mm (0.0787 +0.0394 in. or +0.0000 in.) between the outer end of the switch and the spring (3).
Subtask 38-14-00-865-066-A ** ON A/C NOT FOR ALL (1) Adjust the overflow valve-limit switch 5MP.
(a) Turn the fill/drain handle (3254MM) to the left and pull it out 31.0 +2 mm or -2 mm (1.2205 +0.0787 in. or -0.0787 in.)
Dimension A.
NOTE: You must hold the fill/drain handle in this position to do the adjustment.
(b) Loosen the bolts (2) on the bracket of the switch. (c) Move the switch assembly in the direction of the control cam (1) until you hear a click.
(d) Tighten the bolts (2).
(e) Make sure that the switch 5MP is aligned with the control cam (1).
(f) Release the control handle to the Normal position.
(g) Make sure that Dimension B has a minimum clearance of 2.0 +1 mm or -0 mm (0.0787 +0.0394 in. or +0.0000 in.) between the outer end of the switch and the spring (3).
(2) Adjust the drain limit switch 3MP.
(a) Turn the fill/drain handle (3254MM) to the right and pull it out 31.0 +2 mm or -2 mm (1.2205 +0.0787 in. or -0.0787 in.)
Dimension A.
NOTE: You must hold the fill/drain handle in this position to do the adjustment.
(b) Loosen the bolts (2) on the bracket of the switch. (c) Move the switch assembly in the direction of the control cam (1) until you hear a click.
(d) Tighten the bolts (2).
(e) Make sure that the switch 3MP is aligned with the control cam (1).
(f) Release the fill/drain handle to the Normal position.
(g) Make sure that Dimension C has a minimum clearance of 2.0 +1 mm or -0 mm (0.0787 +0.0394 in. or +0.0000 in.) between the outer end of the switch and the spring (3).
B. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
Subtask 38-14-00-720-050-A ** ON A/C NOT FOR ALL | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 2000VU | WATER SYSTEM-QANT-IND | 1MA | B01 |
| ** ON A/C NOT FOR ALL | |||
| 2001VU | WATER SYS-DRAIN | 1MP | B05 |
| ** ON A/C NOT FOR ALL | |||
| 2001VU | WATER-SYS-DRAIN | 1MP | B05 |
C. Functional Test
(1) Do this test.
5. Close-up(1) Do this test.
| ACTION | RESULT |
|---|---|
1.At the service panel 2023VU:
| In the potable water system:
|
2.At the service panel 2023VU:
| In the potable water system:
|
3.At the service panel 2023VU:
| In the potable water system:
|
4.At the service panel 2023VU:
| In the potable water system:
|
Subtask 38-14-00-613-052-A ** ON A/C NOT FOR ALL Subtask 38-14-00-410-059-B ** ON A/C NOT FOR ALL
B. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Install the access panel 161DW.
(3) Close the AFT cargo-compartment door (Ref. AMM TASK 52-30-00-860-002).
(4) Close the access panel 171AL.
(5) Remove the access platform(s).
(6) Remove the WARNING NOTICE(S).
Subtask 38-14-00-862-054-A ** ON A/C NOT FOR ALL (1) Make sure that the work area is clean and clear of tools and other items.
(2) Install the access panel 161DW.
(3) Close the AFT cargo-compartment door (Ref. AMM TASK 52-30-00-860-002).
(4) Close the access panel 171AL.
(5) Remove the access platform(s).
(6) Remove the WARNING NOTICE(S).
Limit Switches 3MP and 5MP Adjustment