Removal of the Indication Box - Potable Water Service panel
TASK 38-14-00-000-004-A
Removal of the Indication Box - Potable Water Service panel
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 38-14-00-861-055-A Subtask 38-14-00-865-067-A
Subtask 38-14-00-020-050-B ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.02 06:25:42 UTC
Removal of the Indication Box - Potable Water Service panel
FIN: 2023VU ** ON A/C NOT FOR ALL
1. Reason for the JobSelf explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | ACCESS PLATFORM 1M(3 FT) |
| No specific | AR | CAP - BLANKING |
| No specific | AR | SAFETY CLIP - CIRCUIT BREAKER |
| No specific | 1 | SCRAPER - NON METALLIC |
| No specific | 1 | WARNING NOTICE(S) |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 171AL |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-42-00-861-001-A | Energize the Ground Service Network from the External Power |
Subtask 38-14-00-861-055-A Subtask 38-14-00-865-067-A
B. Open, safety and tag this(these) circuit breaker(s):
Subtask 38-14-00-010-062-A | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 2000VU | WATER SYSTEM-QANT-IND | 1MA | B01 |
| ** ON A/C NOT FOR ALL | |||
| 2001VU | WATER SYS-QUANT-IND | 1MA | B06 |
| ** ON A/C NOT FOR ALL | |||
| 2001VU | WATER SYS-DRAIN | 1MP | B05 |
| ** ON A/C NOT FOR ALL | |||
| 2001VU | WATER-SYS-DRAIN | 1MP | B05 |
C. Get Access
(1) Put the ACCESS PLATFORM 1M(3 FT) in position below the potable-water service-panel door (referred to as the service door) 171AL.
(2) Open the service door 171AL.
(3) Put the WARNING NOTICE(S) in position to tell persons:
4. Procedure(1) Put the ACCESS PLATFORM 1M(3 FT) in position below the potable-water service-panel door (referred to as the service door) 171AL.
(2) Open the service door 171AL.
(3) Put the WARNING NOTICE(S) in position to tell persons:
- Not to do the servicing of the potable water system.
Subtask 38-14-00-020-050-B ** ON A/C NOT FOR ALL
A. Removal of Indication Box 2023VU
(2) Put the CAP-BLANKING on each disconnected electrical connector and receptacle.
(3) Remove the sealant that is around the flange of the indication box (6) and the potable-water service panel with the SCRAPER - NON METALLIC.
(4) If necessary, remove the indication lights (1) and (2) with their caps from the potable-water service panel.
(5) Remove the screws (3) and the washers (4).
(6) Remove the indication box (6) together with the seal (5).
(7) Discard the seal (5).
Subtask 38-14-00-020-050-C ** ON A/C NOT FOR ALL CAUTION:
MAKE SURE THAT THE ELECTRICAL CONNECTORS ARE CLEAN BEFORE YOU DISCONNECT OR CONNECT THEM. CONTAMINATION ON THE ELECTRICAL CONNECTORS CAN CAUSE DAMAGE TO EQUIPMENT.
(1) Disconnect the electrical connector (7). (2) Put the CAP-BLANKING on each disconnected electrical connector and receptacle.
(3) Remove the sealant that is around the flange of the indication box (6) and the potable-water service panel with the SCRAPER - NON METALLIC.
(4) If necessary, remove the indication lights (1) and (2) with their caps from the potable-water service panel.
(5) Remove the screws (3) and the washers (4).
(6) Remove the indication box (6) together with the seal (5).
(7) Discard the seal (5).
A. Removal of Indication Boxes 2023VU and 2021VU
(1) Remove the indication box (6) as follows:
(b) Put the CAP-BLANKING on each disconnected electrical connector and receptacle.
(c) Remove the sealant that is around the flange of the indication box (6) and the potable-water service panel with the SCRAPER - NON METALLIC.
(d) If necessary, remove the caps (8) with the indication lights (1) and (2) from the potable-water service panel.
(e) Remove the screws (3) and the washers (4).
(f) Remove the indication box (6) together with the seal (5).
(g) Discard the seal (5).
(2) Remove the indication box (16) as follows:
(b) Put the CAP-BLANKING on each disconnected electrical connector and receptacle.
(c) Remove the sealant that is around the flange of the indication box (16) and the potable-water service panel with the SCRAPER - NON METALLIC.
(d) If necessary, remove the caps (8) with the indication lights (11) and (12) from the potable-water service panel.
(e) Remove the screws (13) and the washers (14).
(f) Remove the indication box (16) together with the seal (15).
(g) Discard the seal (15).
(1) Remove the indication box (6) as follows:
CAUTION:
MAKE SURE THAT THE ELECTRICAL CONNECTORS ARE CLEAN BEFORE YOU DISCONNECT OR CONNECT THEM. CONTAMINATION ON THE ELECTRICAL CONNECTORS CAN CAUSE DAMAGE TO EQUIPMENT.
(a) Disconnect the electrical connector (7). (b) Put the CAP-BLANKING on each disconnected electrical connector and receptacle.
(c) Remove the sealant that is around the flange of the indication box (6) and the potable-water service panel with the SCRAPER - NON METALLIC.
(d) If necessary, remove the caps (8) with the indication lights (1) and (2) from the potable-water service panel.
(e) Remove the screws (3) and the washers (4).
(f) Remove the indication box (6) together with the seal (5).
(g) Discard the seal (5).
(2) Remove the indication box (16) as follows:
CAUTION:
MAKE SURE THAT THE ELECTRICAL CONNECTORS ARE CLEAN BEFORE YOU DISCONNECT OR CONNECT THEM. CONTAMINATION ON THE ELECTRICAL CONNECTORS CAN CAUSE DAMAGE TO EQUIPMENT.
(a) Disconnect the electrical connector (17). (b) Put the CAP-BLANKING on each disconnected electrical connector and receptacle.
(c) Remove the sealant that is around the flange of the indication box (16) and the potable-water service panel with the SCRAPER - NON METALLIC.
(d) If necessary, remove the caps (8) with the indication lights (11) and (12) from the potable-water service panel.
(e) Remove the screws (13) and the washers (14).
(f) Remove the indication box (16) together with the seal (15).
(g) Discard the seal (15).
Indication Box 2023VU