Removal of the Preselection Control Unit
TASK 38-13-34-000-001-A
Removal of the Preselection Control Unit
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 38-13-34-861-050-A ** ON A/C NOT FOR ALL Subtask 38-13-34-865-053-A ** ON A/C NOT FOR ALL
Subtask 38-13-34-020-050-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.02 06:25:42 UTC
Removal of the Preselection Control Unit
FIN: 7MA ** ON A/C NOT FOR ALL
1. Reason for the JobSelf explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | CAP - BLANKING |
| No specific | AR | SAFETY CLIP - CIRCUIT BREAKER |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 162CW |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-41-00-861-002-A | Energize the Aircraft Electrical Circuits from the External Power |
| TASK 24-41-00-861-002-A-01 | Energize the Aircraft Electrical Circuits from the APU |
| TASK 24-41-00-861-002-A-02 | Energize the Aircraft Electrical Circuits from Engine 1(2) |
| TASK 52-30-00-860-001-A | Open the FWD or Aft Cargo-Compartment Door with the Yellow Electric Pump |
Subtask 38-13-34-861-050-A ** ON A/C NOT FOR ALL Subtask 38-13-34-865-053-A ** ON A/C NOT FOR ALL
B. Open, safety and tag this(these) circuit breaker(s):
Subtask 38-13-34-010-050-A ** ON A/C NOT FOR ALL | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 2001VU | WATER SYS-QUANT-IND | 1MA | B06 |
C. Get Access
(1) Open the AFT cargo-compartment door (Ref. AMM TASK 52-30-00-860-001).
(2) Remove the access panel 162CW.
4. Procedure(1) Open the AFT cargo-compartment door (Ref. AMM TASK 52-30-00-860-001).
(2) Remove the access panel 162CW.
Subtask 38-13-34-020-050-A ** ON A/C NOT FOR ALL
A. Removal of the Preselection Control Unit
(1) Disconnect the electrical connector (4) 7MA-A.
(2) Remove the screws (2) the washers (3) and remove the preselection control unit (1) 7MA.
(3) Put the CAP-BLANKING on each disconnected electrical connector and receptacle.
(1) Disconnect the electrical connector (4) 7MA-A.
(2) Remove the screws (2) the washers (3) and remove the preselection control unit (1) 7MA.
(3) Put the CAP-BLANKING on each disconnected electrical connector and receptacle.
Preselection Control Unit 7MA