Removal of the Water Service-Panel Door-Switch
TASK 38-13-16-000-001-A
Removal of the Water Service-Panel Door-Switch
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 38-13-16-861-050-A Subtask 38-13-16-865-050-A
Subtask 38-13-16-020-050-A
[Rev.10 from 2021]
2026.04.02 06:25:42 UTC
Removal of the Water Service-Panel Door-Switch
FIN: 5MA
1. Reason for the JobSelf explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE |
| No specific | AR | CAP - BLANKING |
| No specific | AR | SAFETY CLIP - CIRCUIT BREAKER |
| No specific | 1 | WARNING NOTICE(S) |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 161DW, 171AL |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-42-00-861-001-A | Energize the Ground Service Network from the External Power |
| TASK 52-30-00-860-001-A | Open the FWD or Aft Cargo-Compartment Door with the Yellow Electric Pump |
Subtask 38-13-16-861-050-A Subtask 38-13-16-865-050-A
B. Open, safety and tag this(these) circuit breaker(s):
Subtask 38-13-16-010-051-A | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 2000VU | WATER SYSTEM-QANT-IND | 1MA | B01 |
| ** ON A/C NOT FOR ALL | |||
| 2001VU | WATER SYS-QUANT-IND | 1MA | B06 |
C. Get Access
(1) Open and safety the AFT cargo-compartment door (Ref. AMM TASK 52-30-00-860-001).
(2) Set the CARGO COMPT light-switch 8LU on the service panel 2024VU to the ON position.
(3) Remove the access panel 161DW.
(4) Put an ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE in position below the potable water service-panel.
(5) Open the potable-water service-panel door 171AL.
(6) Put the WARNING NOTICE(S) in position to tell persons that the quantity indication system will not operate.
4. Procedure(1) Open and safety the AFT cargo-compartment door (Ref. AMM TASK 52-30-00-860-001).
(2) Set the CARGO COMPT light-switch 8LU on the service panel 2024VU to the ON position.
(3) Remove the access panel 161DW.
(4) Put an ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE in position below the potable water service-panel.
(5) Open the potable-water service-panel door 171AL.
(6) Put the WARNING NOTICE(S) in position to tell persons that the quantity indication system will not operate.
Subtask 38-13-16-020-050-A
A. Removal of the Water Service-Panel Door-Switch 5MA
(1) Disconnect the electrical connector 5MA-A (1).
(2) Put the CAP-BLANKING on each disconnected electrical connector and receptacle.
(4) Remove the nut (4) and the washer (3).
(5) Remove the switch (2).
(1) Disconnect the electrical connector 5MA-A (1).
(2) Put the CAP-BLANKING on each disconnected electrical connector and receptacle.
WARNING:
USE PROTECTIVE GOGGLES AND GLOVES WHEN YOU REMOVE OR INSTALL LOCKWIRE. EACH TIME YOU CUT LOCKWIRE, REMOVE AND DISCARD IT IMMEDIATELY. LOOSE LOCKWIRE CAN CUT YOU OR MAKE YOU BLIND, AND/OR CAN CAUSE DAMAGE.
(3) Remove and discard the lockwire from the nut (4). (4) Remove the nut (4) and the washer (3).
(5) Remove the switch (2).
Water Service-Panel Door-Switch (5MA)