Adjustment of the Stud for Limit-Switch (5MA) of Potable-Water Service-Panel Access-Door (171AL)
TASK 38-13-00-820-801-A
Adjustment of the Stud for Limit-Switch (5MA) of Potable-Water Service-Panel Access-Door (171AL)
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Consumable Materials
C. Work Zones and Access Panels
D. Referenced Information
3. Job Set-up
Subtask 38-13-00-861-053-A Subtask 38-13-00-010-053-A
Subtask 38-13-00-820-050-A
Subtask 38-13-00-410-053-A
[Rev.10 from 2021]
2026.04.02 07:19:15 UTC
Adjustment of the Stud for Limit-Switch (5MA) of Potable-Water Service-Panel Access-Door (171AL)
WARNING:
BE CAREFUL WHEN YOU USE CONSUMABLE MATERIALS. OBEY THE MATERIAL MANUFACTURER'S INSTRUCTIONS AND YOUR LOCAL REGULATIONS.
ZONE: 170
1. Reason for the JobSelf explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE |
| REFERENCE | DESIGNATION |
|---|---|
| (Material No.05BAE1) | Threadlocking Adhesive-- Medium strength - |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 170 | AFT CAB U/FLOOR COMPT AFT BHD OF BULK |
| 171AL |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-41-00-861-002-A | Energize the Aircraft Electrical Circuits from the External Power |
| TASK 24-41-00-861-002-A-01 | Energize the Aircraft Electrical Circuits from the APU |
| TASK 24-41-00-861-002-A-02 | Energize the Aircraft Electrical Circuits from Engine 1(2) |
| TASK 24-41-00-862-002-A | De-energize the Aircraft Electrical Circuits Supplied from the External Power |
| TASK 24-41-00-862-002-A-01 | De-energize the Aircraft Electrical Circuits Supplied from the APU |
| TASK 24-41-00-862-002-A-02 | De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2) |
Subtask 38-13-00-861-053-A Subtask 38-13-00-010-053-A
B. Get Access
(1) Put the ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position below the Potable-Water Service Panel (PWSP).
(2) Open PWSP access door 171AL.
4. Procedure(1) Put the ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position below the Potable-Water Service Panel (PWSP).
(2) Open PWSP access door 171AL.
Subtask 38-13-00-820-050-A
A. Adjustment of the Stud of Limit Switch 5MA
(1) Loosen the nut (3).
(2) Remove the stud (2) with the nut (3) and the washer (4).
(3) Clean the nut (3), the stud (2) and the washer (4).
(4) Apply Threadlocking Adhesive-- Medium strength - (Material No.05BAE1) to the thread of the stud (2).
(6) Carefully close the PWSP access door (1) and listen if you hear a click from limit switch (5).
(a) If you do not hear a click from the limit-switch (5):
1 Open the PWSP access door (1).
2 Turn the stud (2) counterclockwise half a turn.
3 Carefully close the PWSP access door (1).
4 Do the procedure again until you hear a click from the limit-switch (5).
(b) If you hear a click from the limit-switch (5):
1 Open the PWSP access door (1).
2 Turn the stud (2) clockwise half of a turn.
3 Carefully close the PWSP access door (1).
4 Do the procedure again until you do not hear a click from the limit-switch (5).
5 Turn the stud (2) counterclockwise half a turn.
(7) Turn the stud (2) counterclockwise approximately 2 mm (0.079 in.) more.
(8) Hold the stud (2) in position and tighten the nut (3).
Subtask 38-13-00-865-055-A (1) Loosen the nut (3).
(2) Remove the stud (2) with the nut (3) and the washer (4).
(3) Clean the nut (3), the stud (2) and the washer (4).
(4) Apply Threadlocking Adhesive-- Medium strength - (Material No.05BAE1) to the thread of the stud (2).
NOTE: Refer to the manufacturer's instructions for the drying time of the material No. 05BAE1.
(5) Loosely install the stud (2), the nut (3) and the washer (4). (6) Carefully close the PWSP access door (1) and listen if you hear a click from limit switch (5).
(a) If you do not hear a click from the limit-switch (5):
1 Open the PWSP access door (1).
2 Turn the stud (2) counterclockwise half a turn.
3 Carefully close the PWSP access door (1).
4 Do the procedure again until you hear a click from the limit-switch (5).
(b) If you hear a click from the limit-switch (5):
1 Open the PWSP access door (1).
2 Turn the stud (2) clockwise half of a turn.
3 Carefully close the PWSP access door (1).
4 Do the procedure again until you do not hear a click from the limit-switch (5).
5 Turn the stud (2) counterclockwise half a turn.
(7) Turn the stud (2) counterclockwise approximately 2 mm (0.079 in.) more.
(8) Hold the stud (2) in position and tighten the nut (3).
B. Make sure that this(these) circuit breaker(s) is(are) closed:
Subtask 38-13-00-710-053-A | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 2000VU | WATER SYSTEM-QANT-IND | 1MA | B01 |
| ** ON A/C NOT FOR ALL | |||
| 2001VU | WATER SYS-QUANT-IND | 1MA | B06 |
C. Operational Test of the Adjustment of the Stud for Limit-Switch (5MA)
5. Close-up| ACTION | RESULT |
|---|---|
| 1.At the PWSP: | At the Forward Attendant Panel (FAP) 120RH/miscellaneous panel WATER AND WASTE 124RH: |
|
|
|
|
Subtask 38-13-00-410-053-A
A. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Close PWSP access door 171AL.
(3) Remove the ground support and maintenance equipment, the special and standard tools and all other items.
(4) Remove the access platform(s).
Subtask 38-13-00-862-053-A (1) Make sure that the work area is clean and clear of tools and other items.
(2) Close PWSP access door 171AL.
(3) Remove the ground support and maintenance equipment, the special and standard tools and all other items.
(4) Remove the access platform(s).
Stud for Limit-Switch (5MA) of PWSP Access Door (171AL)