W DOC AIRBUS | AMM A320F

Operational Test of the Door Limit Switch


TASK 38-13-00-710-002-A
Operational Test of the Door Limit Switch


1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
1
ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
171AL
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 12-24-38-680-001-A
Draining of the Potable Water System (with Electrical Power)
TASK 12-24-38-680-002-A
Draining of the Potable Water System (without Electrical Power)
TASK 24-41-00-861-002-A
Energize the Aircraft Electrical Circuits from the External Power
TASK 24-41-00-861-002-A-01
Energize the Aircraft Electrical Circuits from the APU
TASK 24-41-00-861-002-A-02
Energize the Aircraft Electrical Circuits from Engine 1(2)
TASK 24-41-00-862-002-A
De-energize the Aircraft Electrical Circuits Supplied from the External Power
TASK 24-41-00-862-002-A-01
De-energize the Aircraft Electrical Circuits Supplied from the APU
TASK 24-41-00-862-002-A-02
De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2)
3. Job Set-up
Subtask 38-13-00-861-051-A
A. Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002).
Subtask 38-13-00-865-051-A
B. Make sure that this(these) circuit breaker(s) is(are) closed:
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
2000VUWATER SYSTEM-QANT-IND1MAB01
** ON A/C NOT FOR ALL
2001VUWATER SYS-QUANT-IND1MAB06
** ON A/C NOT FOR ALL
2001VUWATER SYS-DRAIN1MPB05
** ON A/C NOT FOR ALL
2001VUWATER-SYS-DRAIN1MPB05
Subtask 38-13-00-010-051-A
C. Get Access
   (1) Put an ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE in position below the potable-water service panel.
   (2) Open potable-water service door 171AL.
Subtask 38-13-00-680-050-A
D. If necessary, drain the potable water system (Ref. AMM TASK 12-24-38-680-001) or (Ref. AMM TASK 12-24-38-680-002).
NOTE: The potable water system must be empty for the subsequent test.
4. Procedure
Subtask 38-13-00-710-051-B ** ON A/C NOT FOR ALL
A. Operational Test of the Water Service-Panel Door-Switch 5MA
ACTION
RESULT
1.At the potable-water service panel:
  • Turn cable control handle 3254MM to the FILL position and pull it out.
At the potable-water service panel:

  • The FWD DRAIN VALVE OPEN light goes off.
  • The OVERFLOW VALVE OPEN light comes on.
  • The TANK DRAIN VALVE OPEN light goes off.
  • The TANK FULL light goes off.
  • Push cable control handle 3254MM in and turn to the NORMAL position.
  • The FWD DRAIN VALVE OPEN light goes off.
  • The OVERFLOW VALVE OPEN light goes off.
  • The TANK DRAIN VALVE OPEN light goes off.
  • The TANK FULL light goes off.
  • Turn cable control handle 3254MM to the DRAIN position and pull it out.
  • The FWD DRAIN VALVE OPEN light comes on.
  • The OVERFLOW VALVE OPEN light comes on.
  • The TANK DRAIN VALVE OPEN light comes on.
  • The TANK FULL light goes off.
  • Push cable control handle 3254MM in and turn to the NORMAL position.
  • The FWD DRAIN VALVE OPEN light goes off.
  • The OVERFLOW VALVE OPEN light goes of.
  • The TANK DRAIN VALVE OPEN light goes off.
  • The TANK FULL light goes off.
2.At the potable-water service panel:
  • Close potable-water service door 171AL.
On Forward Attendant Panel (FAP) 120RH/miscellaneous panel WATER AND WASTE 124RH:
  • There is no indication.
At FAP 120RH/miscellaneous panel WATER AND WASTE 124RH:
  • Push and hold the membrane switch IND ON.
  • The FAP gives an indication.
At the potable-water service panel:
  • Open potable-water service door 171AL.
  • The FAP gives an indication.
Subtask 38-13-00-710-051-C ** ON A/C NOT FOR ALL
A. Operational Test of Water Service-Panel Door Switch 5MA
ACTION
RESULT
1.At the potable-water service panel:
  • Turn cable control handle 3254MM to the FILL position and pull it out.
At the potable-water service panel:
  • The FWD DRAIN VALVE OPEN light goes off.
  • The TANK FULL light goes off.
  • Push cable control handle 3254MM in and turn to the NORMAL position.
  • The FWD DRAIN VALVE OPEN light goes off.
  • The TANK FULL light goes off.
  • Turn cable control handle 3254MM to the DRAIN position and pull it out.
  • The FWD DRAIN VALVE OPEN light comes on.
  • The TANK FULL light goes off.
  • Push cable control handle 3254MM in and turn to the NORMAL position.
  • The FWD DRAIN VALVE OPEN light goes off.
  • The TANK FULL light goes off.
2.At the potable-water service panel:
At Flight Attendant Panel (FAP) 120RH:
  • Close potable-water service door 171AL.
  • There is no indication.
  • Open potable-water service door 171AL.
  • The FAP gives an indication.
5. Close-up
Subtask 38-13-00-410-051-A
A. Close Access
   (1) Make sure that the work area is clean and clear of tools and other items.
   (2) Close potable-water service door 171AL.
NOTE: Make sure that the latches are correctly locked and that the door makes a continuous surface with the skin of the aircraft.
   (3) Remove the access platform(s).
Subtask 38-13-00-862-051-A
B. De-energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-862-002).
[Rev.10 from 2021] 2026.04.02 07:19:15 UTC