W DOC AIRBUS | AMM A320F

Removal of the Inline Filters


TASK 38-12-41-000-007-A
Removal of the Inline Filters


1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
1
CONTAINER 10 L(2 1/2 USGAL)
No specific
1
CONTAINER 5 L (1.32 USGAL)
No specific
AR
PLUG - BLANKING
No specific
AR
SAFETY CLIP - CIRCUIT BREAKER
No specific
1
WARNING NOTICE(S)
 B. Referenced Information
REFERENCE
DESIGNATION
TASK 24-42-00-861-001-A
Energize the Ground Service Network from the External Power
TASK 25-45-26-000-001-A
Removal of the Lining
TASK 38-10-00-614-002-A
Depressurization of the Potable Water System
3. Job Set-up
Subtask 38-12-41-861-056-A ** ON A/C NOT FOR ALL
A. Energize the ground service network
(Ref. AMM TASK 24-42-00-861-001).
Subtask 38-12-41-010-059-A ** ON A/C NOT FOR ALL
B. Get Access
   (1) Remove the lining (Ref. AMM TASK 25-45-26-000-001).
NOTE: Only necessary, if the electronic water faucet is installed.
Subtask 38-12-41-865-066-A ** ON A/C NOT FOR ALL
C. Open, safety and tag this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
2001VUVACU TOIL SYS-LAV PWR-M34MGA04
2001VUVACU TOIL SYS-LAV PWR-D39MGA03
2001VUVACU TOIL SYS-LAV PWR-L45MGA02
2001VUVACU TOIL SYS-LAV PWR-A32MGA01
Subtask 38-12-41-860-064-A ** ON A/C NOT FOR ALL
D. Aircraft Maintenance Configuration
   (1) Install the hoses on the drain masts 4DU and 14DU.
   (2) Put the containers below the drain masts 4DU and 14DU.
   (3) Put the ends of the hoses into the CONTAINER 10 L(2 1/2 USGAL).
   (4) Release the pressure from the potable water system (Ref. AMM TASK 38-10-00-614-002).
   (5) In the lavatory, turn the potable-water shutoff valve to the CLOSED position.
   (6) Put a CONTAINER 5 L (1.32 USGAL) below the related connections.
Subtask 38-12-41-941-051-A ** ON A/C NOT FOR ALL
E. Safety Precautions
   (1) Put the WARNING NOTICE(S) in position to tell persons not to open the potable-water shutoff valve in the lavatory.
4. Procedure
Subtask 38-12-41-020-056-A ** ON A/C NOT FOR ALL
WARNING: MAKE SURE THAT THE EQUIPMENT YOU USE FOR THIS PROCEDURE IS CLEAN AND APPROVED FOR THE POTABLE WATER SYSTEM. IF NOT IT CAN CAUSE CONTAMINATION OF THE POTABLE WATER SYSTEM.
WARNING: MAKE SURE THAT THE WATER TANK IS DEPRESSURIZED.
WARNING: DO NOT TOUCH THE WATER HEATER UNTIL IT IS SUFFICIENTLY COOL TO PREVENT BURNS WHEN YOU DO THE MAINTENANCE TASK(S).
A. Removal of the Inline Filters
NOTE: This procedure is the same for all of the lavatories which have the electronic water faucet.
   (1) Make match marks on the items.
NOTE: To prevent errors on the assembly, it is necessary to put marks on the parts before you disassemble them.
   (2) Make sure that there is no pressure in the potable water line.
   (3) Disconnect the aircraft water-inlet-hose fittings (3) and (4) from the hydraulic box (1) and remove the inline filters (2).
   (4) Put the PLUG-BLANKING in each disconnected line end.