W DOC AIRBUS | AMM A320F

Removal of the Nozzle Assembly


TASK 38-12-41-000-006-A-01
Removal of the Nozzle Assembly


1. Reason for the Job
NOTE: This is an alternative task to remove the nozzle assembly with a different tool.
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
1
CONTAINER 10 L(2 1/2 USGAL)
No specific
AR
SAFETY CLIP - CIRCUIT BREAKER
No specific
AR
WARNING NOTICE(S)
90104701
1
KEY
 B. Referenced Information
REFERENCE
DESIGNATION
TASK 24-42-00-861-001-A
Energize the Ground Service Network from the External Power
F Nozzle Assembly ** ON A/C NOT FOR ALL
F Nozzle Assembly ** ON A/C NOT FOR ALL
3. Job Set-up
Subtask 38-12-41-861-062-A ** ON A/C NOT FOR ALL
A. Energize the ground service network
(Ref. AMM TASK 24-42-00-861-001).
Subtask 38-12-41-010-063-A ** ON A/C NOT FOR ALL
B. Get Access
   (1) Install the hoses on drain masts 4DU and 14DU.
   (2) Put a CONTAINER 10 L(2 1/2 USGAL) below drain masts 4DU and 14DU.
   (3) Put the ends of the hoses into the CONTAINER 10 L(2 1/2 USGAL).
   (4) In the lavatory, turn the potable-water shutoff valve to the CLOSED position.
   (5) In the lavatory, operate the water faucet until no more water flows into the washbasin.
Subtask 38-12-41-865-082-A ** ON A/C NOT FOR ALL
C. Open, safety and tag this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
2001VUVACU TOIL SYS-LAV PWR-A32MGA01
** ON A/C NOT FOR ALL
2001VUVACU TOIL SYS-LAV PWR-E34MGA04
2001VUVACU TOIL SYS-LAV PWR-D39MGA03
** ON A/C NOT FOR ALL
2001VUVACU TOIL SYS-LAV PWR-G34MGA04
2001VUVACU TOIL SYS-LAV PWR-F39MGA03
2001VUVACU TOIL SYS-LAV PWR-D45MGA02
** ON A/C NOT FOR ALL
2001VUVACU TOIL SYS-LAV PWR-L45MGA02
Subtask 38-12-41-941-053-A ** ON A/C NOT FOR ALL
D. Safety Precautions
   (1) Put the WARNING NOTICE(S) in position to tell persons not to use the toilet(s) or open the potable-water shutoff valve(s).
4. Procedure
Subtask 38-12-41-020-062-A ** ON A/C NOT FOR ALL
A. Removal of the Nozzle Assembly
NOTE: The procedure for the removal of the nozzle assembly is the same for all the lavatories.
   (1) Make marks on items before you disassemble them to prevent errors when you assemble them.
   (2) Use a 90104701 KEY (4) to remove the nozzle assembly (5) from the water faucet outlet (1).
   (3) Remove the washer (2) from the nozzle (3).
[Rev.10 from 2021] 2026.04.02 06:25:40 UTC