Removal of the Self-Closing Element
TASK 38-12-41-000-002-A
Removal of the Self-Closing Element
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Referenced Information
3. Job Set-up
Subtask 38-12-41-861-050-A ** ON A/C NOT FOR ALL Subtask 38-12-41-010-054-A ** ON A/C NOT FOR ALL
Subtask 38-12-41-020-051-D ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.02 06:25:39 UTC
Removal of the Self-Closing Element
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | ALLEN KEY - DRIVER PNR ISO 2936-2.5 |
| No specific | 1 | CONTAINER - CLEAN, APPLICABLE |
| No specific | 1 | PLUG - BLANKING |
| W035090087 | 1 | SPECIAL KEY |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-41-00-861-002-A | Energize the Aircraft Electrical Circuits from the External Power |
| TASK 24-41-00-861-002-A-01 | Energize the Aircraft Electrical Circuits from the APU |
| TASK 24-41-00-861-002-A-02 | Energize the Aircraft Electrical Circuits from Engine 1(2) |
| TASK 38-12-41-000-008-A | Removal of the Cartridge Assembly |
Subtask 38-12-41-861-050-A ** ON A/C NOT FOR ALL Subtask 38-12-41-010-054-A ** ON A/C NOT FOR ALL
B. Get Access
(1) Open the door of the lavatory.
(2) Close the potable water-shutoff valve.
4. Procedure(1) Open the door of the lavatory.
(2) Close the potable water-shutoff valve.
Subtask 38-12-41-020-051-D ** ON A/C NOT FOR ALL
A. Removal of the Water-Faucet Self-Closing Element
(2) Remove the screw (1) with an ALLEN KEY - DRIVER PNR ISO 2936-2.5 and remove the cap assembly (2) from the faucet housing (7).
(3) Remove and discard the spring clip (3).
(4) Remove the grip sleeve (4) and the spring (5).
(5) Use a W035090087 SPECIAL KEY to remove the self-closing element (6).
(6) Put the self-closing element (6) in the CONTAINER - CLEAN, APPLICABLE with water.
(8) Put a PLUG - BLANKING in the faucet housing (7).
NOTE: This procedure for the removal of the water-faucet self-closing element is the same in all lavatories.
(1) Make sure that there is no pressure in the potable water line. (2) Remove the screw (1) with an ALLEN KEY - DRIVER PNR ISO 2936-2.5 and remove the cap assembly (2) from the faucet housing (7).
(3) Remove and discard the spring clip (3).
(4) Remove the grip sleeve (4) and the spring (5).
(5) Use a W035090087 SPECIAL KEY to remove the self-closing element (6).
(6) Put the self-closing element (6) in the CONTAINER - CLEAN, APPLICABLE with water.
NOTE: The self-closing element can be damaged if kept dry.
(7) If necessary, remove the cartridge assembly from the faucet housing (7) (Ref. AMM TASK 38-12-41-000-008). (8) Put a PLUG - BLANKING in the faucet housing (7).
Selfclosing - Element