W DOC AIRBUS | AMM A320F

Removal of the Water Heater


TASK 38-12-16-000-001-A
Removal of the Water Heater


WARNING: BE CAREFUL WHEN YOU USE CONSUMABLE MATERIALS. OBEY THE MATERIAL MANUFACTURER'S INSTRUCTIONS AND YOUR LOCAL REGULATIONS.
ZONE: 200
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
CAP - BLANKING
No specific
1
CONTAINER 1 L (1/4 USGAL)
No specific
1
FLASHLIGHT
No specific
1
MIRROR - INSPECTION, FLEXIBLE
No specific
AR
PLUG - BLANKING
No specific
AR
SAFETY CLIP - CIRCUIT BREAKER
 B. Consumable Materials
REFERENCE
DESIGNATION
(Material No.14SBA1)
Textile-Lint free Cotton -
 C. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
200
UPPER HALF FUSELAGE
 D. Referenced Information
REFERENCE
DESIGNATION
TASK 24-42-00-861-001-A
Energize the Ground Service Network from the External Power
TASK 38-10-00-614-002-A
Depressurization of the Potable Water System
3. Job Set-up
Subtask 38-12-16-861-051-A
A. Energize the ground service network
(Ref. AMM TASK 24-42-00-861-001).
Subtask 38-12-16-614-050-A
B. Depressurize the potable water system (Ref. AMM TASK 38-10-00-614-002).
Subtask 38-12-16-865-058-A
C. Open, safety and tag this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
2000VULAV FWD & MID-HOT WATER-A1MBF02
** ON A/C NOT FOR ALL
2000VULAV FWD-HOT WATER-A1MBF02
** ON A/C NOT FOR ALL
2001VULAVATORY AFT-HOT WATER-D2MBB02
** ON A/C NOT FOR ALL
2001VULAV AFT-HOT WATER-E9MBB03
** ON A/C NOT FOR ALL
2001VULAV AFT-HOT WATER-D2MBB02
** ON A/C NOT FOR ALL
2001VULAV AFT-HOT WATER-G9MBB03
2001VULAV AFT-HOT WATER-D/F2MBB02
** ON A/C NOT FOR ALL
2001VULAV AFT-HOT WATER9MBB03
2001VULAV AFT-HOT WATER2MBB02
** ON A/C NOT FOR ALL
2001VULAV AFT-HOT WATER-E/L9MBB03
** ON A/C NOT FOR ALL
2001VULAV AFT-HOT WATER-L9MBC04
** ON A/C NOT FOR ALL
2001VULAV AFT-HOT WATER-D/L2MBB02
** ON A/C NOT FOR ALL
2001VULAV AFT-HOT WATER-M9MBB03
Subtask 38-12-16-010-050-B
D. Get Access
   (1) Get access to the lavatory.
   (2) Turn the shutoff valve (9) to the CLOSED position.
   (3) Turn the switch (7) to the OFF position:
     (a) If necessary, use a FLASHLIGHT and MIRROR - INSPECTION, FLEXIBLE to find the switch (7) of the water heater (1).
   (4) Push the water faucet to release the pressure from the water heater (1).
4. Procedure
WARNING: DO NOT TOUCH THE WATER HEATER UNTIL IT IS SUFFICIENTLY COOL TO PREVENT BURNS WHEN YOU DO THE MAINTENANCE TASK(S).
Subtask 38-12-16-020-052-C
A. Removal of the Water Heater (1)
   (1) Put a CONTAINER 1 L (1/4 USGAL) below the water heater to collect the unwanted water.
   (2) Disconnect the electrical connector (8).
   (3) Put the CAP-BLANKING on each disconnected electrical connector and receptacle.
   (4) Remove the nut (5) and disconnect the bonding strap (6).
   (5) Disconnect the pipes (3) and (4) from the water heater (1).
   (6) Remove the clamps (2).
   (7) Remove the water heater (1).
   (8) Put the PLUG-BLANKING in each disconnected line end.
   (9) Dry the area with a lint-free cotton cloth, Textile-Lint free Cotton - (Material No.14SBA1) .
[Rev.10 from 2021] 2026.04.02 06:25:39 UTC