Removal of a Potable Water-Shutoff Valve
TASK 38-12-14-000-001-A
Removal of a Potable Water-Shutoff Valve
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 38-12-14-861-050-A Subtask 38-12-14-614-051-A Subtask 38-12-14-865-053-A
Subtask 38-12-14-020-050-C
[Rev.10 from 2021]
2026.04.02 06:25:39 UTC
Removal of a Potable Water-Shutoff Valve
NOTE: The removal of the shutoff valve is the same in all the lavatories.
ZONE: 200
1. Reason for the JobSelf explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | CONTAINER 1 L (1/4 USGAL) |
| No specific | AR | SAFETY CLIP - CIRCUIT BREAKER |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 200 | UPPER HALF FUSELAGE |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-41-00-861-002-A | Energize the Aircraft Electrical Circuits from the External Power |
| TASK 24-41-00-861-002-A-01 | Energize the Aircraft Electrical Circuits from the APU |
| TASK 24-41-00-861-002-A-02 | Energize the Aircraft Electrical Circuits from Engine 1(2) |
| TASK 25-45-22-000-001-A | Removal of the Toilet Shroud and the Seat |
| TASK 38-10-00-614-002-A | Depressurization of the Potable Water System |
Subtask 38-12-14-861-050-A Subtask 38-12-14-614-051-A Subtask 38-12-14-865-053-A
C. Open, safety and tag this(these) circuit breaker(s):
Subtask 38-12-14-010-051-C | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 2000VU | WATER SYSTEM-QANT-IND | 1MA | B01 |
| ** ON A/C NOT FOR ALL | |||
| 2001VU | WATER SYS-QUANT-IND | 1MA | B06 |
| ** ON A/C NOT FOR ALL | |||
| 2001VU | WATER SYS-DRAIN | 1MP | B05 |
| ** ON A/C NOT FOR ALL | |||
| 2001VU | WATER-SYS-DRAIN | 1MP | B05 |
D. Get Access
(1) Get access to the passenger cabin.
(2) Open the door of the lavatory.
(3) Open the sanitary cabinet door.
(4) Remove the toilet shroud (Ref. AMM TASK 25-45-22-000-001)
(5) Put a CONTAINER 1 L (1/4 USGAL) below the shutoff valve (12).
4. Procedure(1) Get access to the passenger cabin.
(2) Open the door of the lavatory.
(3) Open the sanitary cabinet door.
(4) Remove the toilet shroud (Ref. AMM TASK 25-45-22-000-001)
(5) Put a CONTAINER 1 L (1/4 USGAL) below the shutoff valve (12).
Subtask 38-12-14-020-050-C
A. Removal of the Shutoff Valve (12)
(1) Disconnect the pipe connections (8).
(2) Remove the counter sink screws (4) and the counter sink washers (5).
(3) Remove the shutoff valve (12) together with the bracket (9).
(4) If necessary remove the bolts (11) the washers (10) and the bracket (9) from the shutoff valve (12).
(5) If necessary remove the control rod (2)
(a) Remove the nuts (13) the washers (14) and the counter sink screws (1).
(b) remove the control rod (2) together with the brackets (3) and (6).
(1) Disconnect the pipe connections (8).
(2) Remove the counter sink screws (4) and the counter sink washers (5).
(3) Remove the shutoff valve (12) together with the bracket (9).
(4) If necessary remove the bolts (11) the washers (10) and the bracket (9) from the shutoff valve (12).
(5) If necessary remove the control rod (2)
(a) Remove the nuts (13) the washers (14) and the counter sink screws (1).
(b) remove the control rod (2) together with the brackets (3) and (6).
Shutoff Valve