W DOC AIRBUS | AMM A320F

Adjustment of the Water Flow Time of the Water Faucet


TASK 38-12-00-820-001-A
Adjustment of the Water Flow Time of the Water Faucet


1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
2
SCREWDRIVER - FLAT HEAD
No specific
2
STOPWATCH
No specific
1
WRENCH - HEXAGONAL
 B. Referenced Information
REFERENCE
DESIGNATION
TASK 24-41-00-861-002-A
Energize the Aircraft Electrical Circuits from the External Power
TASK 24-41-00-861-002-A-01
Energize the Aircraft Electrical Circuits from the APU
TASK 24-41-00-861-002-A-02
Energize the Aircraft Electrical Circuits from Engine 1(2)
TASK 24-41-00-862-002-A
De-energize the Aircraft Electrical Circuits Supplied from the External Power
TASK 24-41-00-862-002-A-01
De-energize the Aircraft Electrical Circuits Supplied from the APU
TASK 24-41-00-862-002-A-02
De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2)
TASK 38-10-00-614-001-A
Pressurization of the Potable Water System from a Ground Air Supply
TASK 38-10-00-614-002-A
Depressurization of the Potable Water System
TASK 38-10-00-614-003-A
Pressurization of the Potable Water System with the Compressor
F Water-Flow Time Adjustment ** ON A/C NOT FOR ALL
3. Job Set-up
Subtask 38-12-00-861-054-A ** ON A/C NOT FOR ALL
A. Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002).
Subtask 38-12-00-010-055-A ** ON A/C NOT FOR ALL
B. Get Access
   (1) Open the related lavatory door.
   (2) Make sure that the potable-water shutoff valve is open.
Subtask 38-12-00-865-061-A ** ON A/C NOT FOR ALL
C. Make sure that this(these) circuit breaker(s) is(are) closed:
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
2000VULAV FWD & MID-HOT WATER-A1MBF02
** ON A/C NOT FOR ALL
2000VUWATER SYSTEM-QANT-IND1MAB01
** ON A/C NOT FOR ALL
2000VULAV FWD-HOT WATER-A1MBF02
** ON A/C NOT FOR ALL
2001VUWATER SYS-QUANT-IND1MAB06
** ON A/C NOT FOR ALL
2001VULAVATORY AFT-HOT WATER-D2MBB02
** ON A/C NOT FOR ALL
2001VULAV AFT-HOT WATER-E9MBB03
** ON A/C NOT FOR ALL
2001VULAV AFT-HOT WATER-D2MBB02
** ON A/C NOT FOR ALL
2001VULAV AFT-HOT WATER-G9MBB03
2001VULAV AFT-HOT WATER-D/F2MBB02
** ON A/C NOT FOR ALL
2001VULAV AFT-HOT WATER9MBB03
2001VULAV AFT-HOT WATER2MBB02
** ON A/C NOT FOR ALL
2001VULAV AFT-HOT WATER-E/L9MBB03
** ON A/C NOT FOR ALL
2001VULAV AFT-HOT WATER-L9MBC04
** ON A/C NOT FOR ALL
2001VULAV AFT-HOT WATER-D/L2MBB02
Subtask 38-12-00-614-052-A ** ON A/C NOT FOR ALL
D. Pressurize the potable water system (Ref. AMM TASK 38-10-00-614-001) or (Ref. AMM TASK 38-10-00-614-003).
4. Procedure
Subtask 38-12-00-820-050-D ** ON A/C NOT FOR ALL
A. Adjustment of the Water Flow Time of the Water Faucet
F Water-Flow Time Adjustment ** ON A/C NOT FOR ALL
   (1) Make sure that the water nozzle is clean and not calcified before you do this task.
NOTE: The pre-adjusted water flow time of the water faucet is 10 +2 -2 seconds.
Table 1 - Water-Faucet Data Setting
-------------------------------------------------------------------------------
I System Press I Normal Operating I Duration of I Flow Rate I
I I Press I Water Flow I I
--------------------I----------------------I----------------I-----------------I
I Between I Between I Between I I
I 0.50 and 3.06 bar I 1.42 and 1.62 bar I 3 and 16 I 1.7 l/min I
I (7 and 44 psi) I (21 and 23 psi) I seconds I(0.45 USgal/min) I
-------------------------------------------------------------------------------

   (2) Set the water-faucet temperature control to the central position before you adjust the water flow time.
   (3) Remove the knob (3):
     (a) Remove the cover (1) from the screw (2).
     (b) Loosen and remove the screw (2) with a WRENCH - HEXAGONAL from the knob (3).
     (c) Remove the knob (3) from the water faucet (4).
   (4) Use a SCREWDRIVER - FLAT HEAD and adjust the water flow time as follows:
     (a) Turn the adjusting screw in the water faucet (4) clockwise to decrease the water flow time.
     (b) Turn the adjusting screw in the water faucet (4) counterclockwise to increase the water flow time.
   (5) Operate the water faucet (4).
   (6) Use a STOPWATCH and make sure that the water flows for between 3 and 16 seconds.
NOTE: The water pressure and the temperature can have an effect on the water flow time of the water faucet. The colder the water, the longer is the flow time.
   (7) Make sure that the water flow time of the water faucet is not more than 16 seconds.
   (8) Do the procedure again if the water flow time is not satisfactory.
   (9) Install the knob (3):
     (a) Put the knob (3) in its installation position.
     (b) Install and tighten the screw (2) with WRENCH - HEXAGONAL.
     (c) Install the cover (1).
Subtask 38-12-00-820-050-K ** ON A/C NOT FOR ALL
A. Adjustment of the Water Flow Time of the Water Faucet
F Water-Flow Time Adjustment ** ON A/C NOT FOR ALL
   (1) Make sure that the water nozzle is clean and not calcified before you do this task.
NOTE: The pre-adjusted water flow time of the water faucet is 10 +2 -2 seconds.
Table 1 - Water-Faucet Data Setting
-------------------------------------------------------------------------------
I System Press I Normal Operating I Duration of I Flow Rate I
I I Press I Water Flow I I
--------------------I----------------------I----------------I-----------------I
I Between I Between I Between I I
I 0.50 and 3.06 bar I 1.42 and 1.62 bar I 4 and 6 I 1.7 l/min I
I (7 and 44 psi) I (21 and 23 psi) I seconds I(0.45 USgal/min) I
-------------------------------------------------------------------------------

   (2) Set the water-faucet temperature control to the central position before you adjust the water flow time.
   (3) Remove the knob (3):
     (a) Remove the cover (1) from the screw (2).
     (b) Loosen and remove the screw (2) with a WRENCH - HEXAGONAL from the knob (3).
     (c) Remove the knob (3) from the water faucet (4).
   (4) Use a SCREWDRIVER - FLAT HEAD and adjust the water-flow time as follows:
     (a) Turn the adjusting screw in the water faucet (4) clockwise to decrease the flow time.
     (b) Turn the adjusting screw in the water faucet (4) counterclockwise to increase the flow time.
   (5) Operate the water faucet (4).
   (6) Use a STOPWATCH and make sure that the water flows for between 4 and 6 seconds.
NOTE: The water pressure and the temperature can have an effect on the water flow time of the water faucet. The colder the water, the longer is the flow time.
   (7) Make sure that the water flow time of the water faucet is not more than 6 seconds.
   (8) Do the procedure again if the flow time is not satisfactory.
   (9) Install the knob (3):
     (a) Put the knob (3) in its installation position.
     (b) Install and tighten the screw (2) with WRENCH - HEXAGONAL.
     (c) Install the cover (1).
Subtask 38-12-00-820-052-A ** ON A/C NOT FOR ALL
B. Adjustment of the Water Flow Time of the Water faucet
F Water-Flow Time Adjustment ** ON A/C NOT FOR ALL
   (1) Make sure that the water nozzle is clean and not calcified before you do this task.
NOTE: The pre-adjusted water flow time of the water faucet is 10 +2 -2 seconds.
Table 1 - Water-Faucet Data Setting
-------------------------------------------------------------------------------
I System Press I Normal Operating I Duration of I Flow Rate I
I I Press I Water Flow I I
--------------------I----------------------I----------------I-----------------I
I Between I Between I Between I I
I 0.49 and 3.05 bar I 1.42 and 1.62 bar I 3 and 16 I 1.7 l/min I
I (7 and 44 psi) I (21 and 23 psi) I seconds I(0.45 USgal/min) I
-------------------------------------------------------------------------------

   (2) Set the water-faucet temperature control to the central position before you adjust the water flow time.
   (3) Remove the push-cap (2):
     (a) Loosen and remove the setscrew (3) from the push-cap (2).
     (b) Remove the push-cap (2) from the water faucet assembly (1).
   (4) Adjust the water flow time as follows:
     (a) Use a SCREWDRIVER - FLAT HEAD to adjust the water flow time:
  • Turn the control needle in the water faucet assembly (1) clockwise to decrease the water flow time.
  • Turn the control needle in the water faucet assembly (1) counterclockwise to increase the water flow time.
   (5) Measure the water flow time of the water faucet:
     (a) Push the pushbutton guide (4) and use a STOPWATCH to measure the water flow time.
     (b) Make sure that the water flows between 3 and 16 seconds.
NOTE: The water pressure and the temperature can have an effect on the water flow time of the water faucet.
     (c) Make sure that the water flow time of the water faucet is not more than 16 seconds.
   (6) Do the procedure again if the water flow time is not satisfactory.
   (7) Install the push-cap (2):
     (a) Put the push-cap (2) in its installation position.
     (b) Install and tighten the screw (3).
5. Close-up
Subtask 38-12-00-614-053-A ** ON A/C NOT FOR ALL
A. Depressurize the potable water system (Ref. AMM TASK 38-10-00-614-002).
Subtask 38-12-00-410-057-A ** ON A/C NOT FOR ALL
B. Close Access
   (1) Make sure that the work area is clean and clear of tools and other items.
   (2) Close the related lavatory door.
Subtask 38-12-00-862-054-A ** ON A/C NOT FOR ALL
C. De-energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-862-002).
[Rev.10 from 2021] 2026.04.02 06:25:38 UTC