Operational Test of the Potable Water-Distribution System (with the Air Supply Boost-System)
TASK 38-12-00-710-003-A
Operational Test of the Potable Water-Distribution System (with the Air Supply Boost-System)
Self explanatory
2. Job Set-up Information
A. Work Zones and Access Panels
B. Referenced Information
3. Job Set-up
Subtask 38-12-00-861-051-A ** ON A/C NOT FOR ALL
Subtask 38-12-00-710-053-A ** ON A/C NOT FOR ALL
Subtask 38-12-00-410-050-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.02 06:25:38 UTC
Operational Test of the Potable Water-Distribution System (with the Air Supply Boost-System)
NOTE: Only the operational test of the water-distribution system in a lavatory/galley is given. The procedure is the same for all other lavatories/galleys.
1. Reason for the JobSelf explanatory
2. Job Set-up Information
A. Work Zones and Access Panels
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 171AL |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 12-15-38-613-001-A | Fill the Potable Water Tank System (Aircraft Electrical Power Available) |
| TASK 24-41-00-861-002-A | Energize the Aircraft Electrical Circuits from the External Power |
| TASK 24-41-00-861-002-A-01 | Energize the Aircraft Electrical Circuits from the APU |
| TASK 24-41-00-861-002-A-02 | Energize the Aircraft Electrical Circuits from Engine 1(2) |
| TASK 24-41-00-862-002-A | De-energize the Aircraft Electrical Circuits Supplied from the External Power |
| TASK 24-41-00-862-002-A-01 | De-energize the Aircraft Electrical Circuits Supplied from the APU |
| TASK 24-41-00-862-002-A-02 | De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2) |
Subtask 38-12-00-861-051-A ** ON A/C NOT FOR ALL
A. Energize the aircraft electrical circuits (Ref. AMM TASK 24-41-00-861-002).
Subtask 38-12-00-865-060-A ** ON A/C NOT FOR ALL NOTE: The air-compressor 8MD will operate when the aircraft electrical circuits are energized, and the air-pressure in the tank is below 22 psi.
B. Make sure that this(these) circuit breaker(s) is(are) closed:
Subtask 38-12-00-010-050-A ** ON A/C NOT FOR ALL | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 2001VU | WATER-SYSTEM-DEPRESS | 1MD | F03 |
| ** ON A/C NOT FOR ALL | |||
| 2001VU | WATER SYS-QUANT-IND | 1MA | B06 |
| 2001VU | WATER SYS-AIR-COMPRESSOR | 19MD | F01 |
| ** ON A/C NOT FOR ALL | |||
| 2001VU | WATER-SYSTEM-DEPRESS | 1MD | D05 |
C. Get Access
(1) Get access to the lavatory/galley.
(2) Make sure that the potable water shutoff valve in the lavatory/galley is open.
Subtask 38-12-00-613-052-A ** ON A/C NOT FOR ALL Subtask 38-12-00-210-050-A ** ON A/C NOT FOR ALL 4. Procedure(1) Get access to the lavatory/galley.
(2) Make sure that the potable water shutoff valve in the lavatory/galley is open.
Subtask 38-12-00-710-053-A ** ON A/C NOT FOR ALL
A. Test
(1) Do this test.
5. Close-up(1) Do this test.
| ACTION | RESULT |
|---|---|
1.In the lavatory/galley:
| In the lavatory/galley:
|
Subtask 38-12-00-410-050-A ** ON A/C NOT FOR ALL
A. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the lavatory door.
Subtask 38-12-00-862-051-A ** ON A/C NOT FOR ALL (1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the lavatory door.