Operational Test of the Potable Water-Distribution System (with the Air Supply Boost-System)


TASK 38-12-00-710-003-A
Operational Test of the Potable Water-Distribution System (with the Air Supply Boost-System)


NOTE: Only the operational test of the water-distribution system in a lavatory/galley is given. The procedure is the same for all other lavatories/galleys.
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
171AL
 B. Referenced Information
REFERENCE
DESIGNATION
TASK 12-15-38-613-001-A
Fill the Potable Water Tank System (Aircraft Electrical Power Available)
TASK 24-41-00-861-002-A
Energize the Aircraft Electrical Circuits from the External Power
TASK 24-41-00-861-002-A-01
Energize the Aircraft Electrical Circuits from the APU
TASK 24-41-00-861-002-A-02
Energize the Aircraft Electrical Circuits from Engine 1(2)
TASK 24-41-00-862-002-A
De-energize the Aircraft Electrical Circuits Supplied from the External Power
TASK 24-41-00-862-002-A-01
De-energize the Aircraft Electrical Circuits Supplied from the APU
TASK 24-41-00-862-002-A-02
De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2)
3. Job Set-up
Subtask 38-12-00-861-051-A ** ON A/C NOT FOR ALL
A. Energize the aircraft electrical circuits (Ref. AMM TASK 24-41-00-861-002).
NOTE: The air-compressor 8MD will operate when the aircraft electrical circuits are energized, and the air-pressure in the tank is below 22 psi.
Subtask 38-12-00-865-060-A ** ON A/C NOT FOR ALL
B. Make sure that this(these) circuit breaker(s) is(are) closed:
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
2001VUWATER-SYSTEM-DEPRESS1MDF03
** ON A/C NOT FOR ALL
2001VUWATER SYS-QUANT-IND1MAB06
2001VUWATER SYS-AIR-COMPRESSOR19MDF01
** ON A/C NOT FOR ALL
2001VUWATER-SYSTEM-DEPRESS1MDD05
Subtask 38-12-00-010-050-A ** ON A/C NOT FOR ALL
C. Get Access
   (1) Get access to the lavatory/galley.
   (2) Make sure that the potable water shutoff valve in the lavatory/galley is open.
Subtask 38-12-00-613-052-A ** ON A/C NOT FOR ALL
D. Fill the potable water system (Ref. AMM TASK 12-15-38-613-001).
Subtask 38-12-00-210-050-A ** ON A/C NOT FOR ALL
E. Make sure that the access panel 171AL is closed.
4. Procedure
Subtask 38-12-00-710-053-A ** ON A/C NOT FOR ALL
A. Test
   (1) Do this test.
ACTION
RESULT
1.In the lavatory/galley:
  • operate the water faucet.
In the lavatory/galley:
  • water flows from the water faucet.
5. Close-up
Subtask 38-12-00-410-050-A ** ON A/C NOT FOR ALL
A. Close Access
   (1) Make sure that the work area is clean and clear of tools and other items.
   (2) Close the lavatory door.
Subtask 38-12-00-862-051-A ** ON A/C NOT FOR ALL
B. De-energize the aircraft electrical circuits (Ref. AMM TASK 24-41-00-862-002).