Deactivation of the Lavatory Water Supply
TASK 38-12-00-040-001-A
Deactivation of the Lavatory Water Supply
1. Reason for the Job
A. Fixtures, Tools, Test and Support Equipment
B. Referenced Information
3. Job Set-up
Subtask 38-12-00-861-056-A Subtask 38-12-00-614-054-A Subtask 38-12-00-865-062-A
Subtask 38-12-00-040-050-B
Subtask 38-12-00-410-058-A
[Rev.10 from 2021]
2026.04.02 06:25:38 UTC
Deactivation of the Lavatory Water Supply
1. Reason for the Job
NOTE: This deactivation task is not related to AFM-CDL/MMEL item.
2. Job Set-up InformationA. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | PLACARD |
| No specific | AR | SAFETY CLIP - CIRCUIT BREAKER |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-42-00-861-001-A | Energize the Ground Service Network from the External Power |
| TASK 24-42-00-862-001-A | De-energize the Ground Service Network Supplied from the External Power |
| TASK 38-10-00-614-001-A | Pressurization of the Potable Water System from a Ground Air Supply |
| TASK 38-10-00-614-002-A | Depressurization of the Potable Water System |
| TASK 38-10-00-614-003-A | Pressurization of the Potable Water System with the Compressor |
Subtask 38-12-00-861-056-A Subtask 38-12-00-614-054-A Subtask 38-12-00-865-062-A
C. Open, safety and tag this(these) circuit breaker(s):
Subtask 38-12-00-010-057-A | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 2000VU | LAV FWD & MID-HOT WATER-A | 1MB | F02 |
| ** ON A/C NOT FOR ALL | |||
| 2000VU | LAV FWD-HOT WATER-A | 1MB | F02 |
| ** ON A/C NOT FOR ALL | |||
| 2001VU | LAVATORY AFT-HOT WATER-D | 2MB | B02 |
| ** ON A/C NOT FOR ALL | |||
| 2001VU | VACU TOIL SYS-LAV PWR-E | 34MG | A04 |
| ** ON A/C NOT FOR ALL | |||
| 2001VU | VACU TOIL SYS-LAV PWR-D | 39MG | A03 |
| ** ON A/C NOT FOR ALL | |||
| 2001VU | LAV AFT-HOT WATER-E | 9MB | B03 |
| ** ON A/C ALL | |||
| 2001VU | VACU TOIL SYS-LAV PWR-A | 32MG | A01 |
| ** ON A/C NOT FOR ALL | |||
| 2001VU | LAV AFT-HOT WATER-D | 2MB | B02 |
| ** ON A/C NOT FOR ALL | |||
| 2001VU | LAV AFT-HOT WATER-G | 9MB | B03 |
| 2001VU | LAV AFT-HOT WATER-D/F | 2MB | B02 |
| ** ON A/C NOT FOR ALL | |||
| 2001VU | VACU TOIL SYS-LAV PWR-G | 34MG | A04 |
| 2001VU | VACU TOIL SYS-LAV PWR-F | 39MG | A03 |
| 2001VU | VACU TOIL SYS-LAV PWR-D | 45MG | A02 |
| ** ON A/C NOT FOR ALL | |||
| 2001VU | LAV AFT-HOT WATER | 9MB | B03 |
| 2001VU | LAV AFT-HOT WATER | 2MB | B02 |
| ** ON A/C NOT FOR ALL | |||
| 2001VU | LAV AFT-HOT WATER-E/L | 9MB | B03 |
| ** ON A/C NOT FOR ALL | |||
| 2001VU | VACU TOIL SYS-LAV PWR-L | 45MG | A02 |
| ** ON A/C NOT FOR ALL | |||
| 2001VU | VACU TOIL SYS-LAV PWR-L | 23MG | A05 |
| 2001VU | LAV AFT-HOT WATER-L | 9MB | C04 |
| ** ON A/C NOT FOR ALL | |||
| 2001VU | LAV AFT-HOT WATER-D/L | 2MB | B02 |
| ** ON A/C NOT FOR ALL | |||
| 2001VU | VACU TOIL SYS-LAV PWR-M | 34MG | A04 |
| 2001VU | LAV AFT-HOT WATER-M | 9MB | B03 |
D. Get access to the related lavatory and open the lavatory sanitation door.
4. ProcedureSubtask 38-12-00-040-050-B
A. Deactivation of the Water Faucet
(1) Turn the potable-water shutoff valve to the SHUT position:
Subtask 38-12-00-614-055-A (1) Turn the potable-water shutoff valve to the SHUT position:
- The water supply stops to the water faucet and the toilet assembly.
NOTE: The toilet assembly is unserviceable at this time.
B. Pressurize the potable water system (Ref. AMM TASK 38-10-00-614-001) or (Ref. AMM TASK 38-10-00-614-003).
5. Close-upSubtask 38-12-00-410-058-A
A. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
Subtask 38-12-00-860-051-A (1) Make sure that the work area is clean and clear of tools and other items.
B. Aircraft Maintenance Configuration
(1) Close and lock the lavatory door.
(a) Put a PLACARD in position to tell persons that the lavatory is unserviceable.
(2) Make an entry in the logbook to record that the lavatory is isolated.
Subtask 38-12-00-862-056-A (1) Close and lock the lavatory door.
(a) Put a PLACARD in position to tell persons that the lavatory is unserviceable.
(2) Make an entry in the logbook to record that the lavatory is isolated.