W DOC AIRBUS | AMM A320F

Deactivation of the Lavatory Water Supply


TASK 38-12-00-040-001-A
Deactivation of the Lavatory Water Supply


1. Reason for the Job
NOTE: This deactivation task is not related to AFM-CDL/MMEL item.
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
1
PLACARD
No specific
AR
SAFETY CLIP - CIRCUIT BREAKER
 B. Referenced Information
REFERENCE
DESIGNATION
TASK 24-42-00-861-001-A
Energize the Ground Service Network from the External Power
TASK 24-42-00-862-001-A
De-energize the Ground Service Network Supplied from the External Power
TASK 38-10-00-614-001-A
Pressurization of the Potable Water System from a Ground Air Supply
TASK 38-10-00-614-002-A
Depressurization of the Potable Water System
TASK 38-10-00-614-003-A
Pressurization of the Potable Water System with the Compressor
3. Job Set-up
Subtask 38-12-00-861-056-A
A. Energize the ground service network
(Ref. AMM TASK 24-42-00-861-001).
Subtask 38-12-00-614-054-A
B. Depressurize the potable water system (Ref. AMM TASK 38-10-00-614-002).
Subtask 38-12-00-865-062-A
C. Open, safety and tag this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
2000VULAV FWD & MID-HOT WATER-A1MBF02
** ON A/C NOT FOR ALL
2000VULAV FWD-HOT WATER-A1MBF02
** ON A/C NOT FOR ALL
2001VULAVATORY AFT-HOT WATER-D2MBB02
** ON A/C NOT FOR ALL
2001VUVACU TOIL SYS-LAV PWR-E34MGA04
** ON A/C NOT FOR ALL
2001VUVACU TOIL SYS-LAV PWR-D39MGA03
** ON A/C NOT FOR ALL
2001VULAV AFT-HOT WATER-E9MBB03
** ON A/C ALL
2001VUVACU TOIL SYS-LAV PWR-A32MGA01
** ON A/C NOT FOR ALL
2001VULAV AFT-HOT WATER-D2MBB02
** ON A/C NOT FOR ALL
2001VULAV AFT-HOT WATER-G9MBB03
2001VULAV AFT-HOT WATER-D/F2MBB02
** ON A/C NOT FOR ALL
2001VUVACU TOIL SYS-LAV PWR-G34MGA04
2001VUVACU TOIL SYS-LAV PWR-F39MGA03
2001VUVACU TOIL SYS-LAV PWR-D45MGA02
** ON A/C NOT FOR ALL
2001VULAV AFT-HOT WATER9MBB03
2001VULAV AFT-HOT WATER2MBB02
** ON A/C NOT FOR ALL
2001VULAV AFT-HOT WATER-E/L9MBB03
** ON A/C NOT FOR ALL
2001VUVACU TOIL SYS-LAV PWR-L45MGA02
** ON A/C NOT FOR ALL
2001VUVACU TOIL SYS-LAV PWR-L23MGA05
2001VULAV AFT-HOT WATER-L9MBC04
** ON A/C NOT FOR ALL
2001VULAV AFT-HOT WATER-D/L2MBB02
** ON A/C NOT FOR ALL
2001VUVACU TOIL SYS-LAV PWR-M34MGA04
2001VULAV AFT-HOT WATER-M9MBB03
Subtask 38-12-00-010-057-A
D. Get access to the related lavatory and open the lavatory sanitation door.
4. Procedure
Subtask 38-12-00-040-050-B
A. Deactivation of the Water Faucet
   (1) Turn the potable-water shutoff valve to the SHUT position:
  • The water supply stops to the water faucet and the toilet assembly.
NOTE: The toilet assembly is unserviceable at this time.
Subtask 38-12-00-614-055-A
B. Pressurize the potable water system (Ref. AMM TASK 38-10-00-614-001) or (Ref. AMM TASK 38-10-00-614-003).
5. Close-up
Subtask 38-12-00-410-058-A
A. Close Access
   (1) Make sure that the work area is clean and clear of tools and other items.
Subtask 38-12-00-860-051-A
B. Aircraft Maintenance Configuration
   (1) Close and lock the lavatory door.
     (a) Put a PLACARD in position to tell persons that the lavatory is unserviceable.
   (2) Make an entry in the logbook to record that the lavatory is isolated.
Subtask 38-12-00-862-056-A
C. De-energize the ground service network
(Ref. AMM TASK 24-42-00-862-001).
[Rev.10 from 2021] 2026.04.02 06:25:38 UTC