Detailed Inspection of the APU Overheat Sensing-Elements
TASK 36-22-17-200-803-A
Detailed Inspection of the APU Overheat Sensing-Elements
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 36-22-17-865-057-A
Subtask 36-22-17-210-053-A
Subtask 36-22-17-410-054-A
[Rev.10 from 2021]
2026.04.01 01:17:25 UTC
Detailed Inspection of the APU Overheat Sensing-Elements
WARNING:
MAKE SURE THAT THE SAFETY DEVICES AND THE WARNING NOTICES ARE IN POSITION BEFORE YOU START A TASK ON OR NEAR:
- THE FLIGHT CONTROLS
- THE FLIGHT CONTROL SURFACES
- THE LANDING GEAR AND RELATED DOORS
- COMPONENTS THAT MOVE.
WARNING:
DO NOT TOUCH THE COMPONENT UNTIL IT IS SUFFICIENTLY
COOL TO PREVENT BURNS.
WARNING:
BEFORE YOU START WORK, YOU MUST PUT ON A SAFETY HARNESS AND ATTACH IT TO THE ACCESS PLATFORM. WITHOUT A SAFETY HARNESS, YOU CAN FALL. THIS CAN KILL YOU OR CAUSE YOU INJURY.
1. Reason for the JobSelf explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | ACCESS PLATFORM 3M (10 FT) |
| No specific | 1 | ACCESS PLATFORM 4M (13 FT)-ADJUSTABLE |
| No specific | AR | SAFETY CLIP - CIRCUIT BREAKER |
| No specific | AR | WARNING NOTICE(S) |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 151DW, 151EW, 151HW, 151JW, 161AW, 161BW, 161CW, 161DW, 312AR, 314AR |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 20-28-00-912-802-A | Electrical Bonding - General Maintenance Procedure |
| TASK 25-55-12-000-001-A | Removal of the Aft Cargo-Compartment Partition at FR65 |
| TASK 25-55-12-400-001-A | Installation of the Aft Cargo-Compartment Partition at FR65 |
| TASK 52-30-00-860-001-A | Open the FWD or Aft Cargo-Compartment Door with the Yellow Electric Pump |
| TASK 52-30-00-860-002-A | Close the FWD or Aft Cargo-Compartment Door with the Yellow Electric Pump |
Subtask 36-22-17-865-057-A
A. Open, safety and tag this(these) circuit breaker(s):
Subtask 36-22-17-860-053-A | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C ALL | |||
| 49VU | AIR BLEED/X FEED/VALVE/BAT | 2HV | D13 |
| 49VU | AIR BLEED/ENG 2/MONG | 3HA2 | D12 |
| 49VU | AIR BLEED/ENG 1/CTL | 2HA1 | D11 |
| 122VU | AIR BLEED/ENG 1/MONG | 3HA1 | Z23 |
| 122VU | AIR BLEED/ENG 2/CTL | 2HA2 | Z22 |
| 122VU | AIR BLEED/X FEED VALVE/NORM | 1HV | Z20 |
B. Aircraft Maintenance Configuration
(1) Put the WARNING NOTICE(S) in position:
Subtask 36-22-17-010-053-A (1) Put the WARNING NOTICE(S) in position:
- In the cockpit, on engine control panel 115VU, to tell persons not to start the engine(s)
- In the cockpit, on AIR COND overhead-control-panel 30VU, to tell persons not to push the APU BLEED pushbutton switch
- On the HP ground connector, to tell persons not to pressurize the pneumatic system.
C. Get Access
(1) Put the ACCESS PLATFORM 4M (13 FT)-ADJUSTABLE in position.
(2) Get access to the APU overheat sensing-elements between FR49 and FR70 from the aft cargo compartment.
(a) Open the aft cargo-compartment door (Ref. AMM TASK 52-30-00-860-001).
(b) Remove the applicable access panels to get access to the APU overheat sensing-elements:
1 Between FR49 and FR52:
(a) Put the ACCESS PLATFORM 3M (10 FT) below the rear fuselage.
(b) Open the applicable access door for the APU overheat sensing-elements:
1 Between FR70 and FR77:
4. Procedure(1) Put the ACCESS PLATFORM 4M (13 FT)-ADJUSTABLE in position.
(2) Get access to the APU overheat sensing-elements between FR49 and FR70 from the aft cargo compartment.
(a) Open the aft cargo-compartment door (Ref. AMM TASK 52-30-00-860-001).
(b) Remove the applicable access panels to get access to the APU overheat sensing-elements:
1 Between FR49 and FR52:
- Remove access panel 151DW.
- Remove access panel 151EW.
- Remove access panel 151HW.
- Remove access panel 151JW.
- Remove access panel 161AW.
- Remove access panel 161BW.
- Remove access panel 161CW.
- Remove partition panel 161DW (Ref. AMM TASK 25-55-12-000-001).
(a) Put the ACCESS PLATFORM 3M (10 FT) below the rear fuselage.
(b) Open the applicable access door for the APU overheat sensing-elements:
1 Between FR70 and FR77:
- Open access door 312AR.
- Open access door 314AR.
Subtask 36-22-17-210-053-A
A. Inspection of the Overheat Sensing Elements
(1) Examine the overheat sensing elements and the element connection assemblies for correct condition. The element tubing must not be twisted and the damage must be in the limits that follow:
(a) The maximum permitted depth of abrasions or dents is 0.05 mm (0.0020 in.).
(b) The minimum permitted tube diameter at a dent is 1.78 mm (0.0701 in.).
(2) Make sure that the clearance between the sensing elements and the duct is 12.7 mm (0.50 in.) minimum, measured along the full length of the sensing element.
(3) Do an inspection of the elements to make sure that they are installed out of the insulation.
(4) Make sure that the clearance between the elements and the duct insulation is the same as at the mounting brackets.
(5) Make sure that the sensing elements are installed with the permitted tolerance.
(6) Make sure that each clamp has a silicon rubber grommet.
(7) Make sure that each mounting bracket, that is installed directly in the duct, has a spacer.
(8) Make sure that the element at FR80 is installed correctly.
(9) Make sure that each mounting bracket and clamp is the correct condition and has no corrosion.
(10) Make sure that the bonding straps are correctly installed (Ref. AMM TASK 20-28-00-912-802).
(11) Make sure that the lockwires are correctly installed on the connection of the sensing elements.
(12) Make sure that the duct insulation is in the correct condition and correctly installed.
(13) Make sure that the sensing elements have no cracks, nicks, sharp edges, bonds, chafing or corrosion.
5. Close-up(1) Examine the overheat sensing elements and the element connection assemblies for correct condition. The element tubing must not be twisted and the damage must be in the limits that follow:
(a) The maximum permitted depth of abrasions or dents is 0.05 mm (0.0020 in.).
(b) The minimum permitted tube diameter at a dent is 1.78 mm (0.0701 in.).
(2) Make sure that the clearance between the sensing elements and the duct is 12.7 mm (0.50 in.) minimum, measured along the full length of the sensing element.
(3) Do an inspection of the elements to make sure that they are installed out of the insulation.
(4) Make sure that the clearance between the elements and the duct insulation is the same as at the mounting brackets.
(5) Make sure that the sensing elements are installed with the permitted tolerance.
(6) Make sure that each clamp has a silicon rubber grommet.
(7) Make sure that each mounting bracket, that is installed directly in the duct, has a spacer.
(8) Make sure that the element at FR80 is installed correctly.
(9) Make sure that each mounting bracket and clamp is the correct condition and has no corrosion.
(10) Make sure that the bonding straps are correctly installed (Ref. AMM TASK 20-28-00-912-802).
(11) Make sure that the lockwires are correctly installed on the connection of the sensing elements.
(12) Make sure that the duct insulation is in the correct condition and correctly installed.
(13) Make sure that the sensing elements have no cracks, nicks, sharp edges, bonds, chafing or corrosion.
Subtask 36-22-17-410-054-A
A. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Install the access panels as applicable:
(a) For the APU overheat sensing-elements between FR49 and FR52:
(5) For the APU overheat sensing-elements between FR70 and FR77:
Subtask 36-22-17-865-058-A (1) Make sure that the work area is clean and clear of tools and other items.
(2) Install the access panels as applicable:
(a) For the APU overheat sensing-elements between FR49 and FR52:
- Install access panel 151DW.
- Install access panel 151EW.
- Install access panel 151HW.
- Install access panel 151JW.
- Install access panel 161AW.
- Install access panel 161BW.
- Install access panel 161CW.
- Install partition panel 161DW (Ref. AMM TASK 25-55-12-400-001).
(5) For the APU overheat sensing-elements between FR70 and FR77:
- Close access door 312AR.
- Close access door 314AR.
B. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
Subtask 36-22-17-942-056-A | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C ALL | |||
| 49VU | AIR BLEED/X FEED/VALVE/BAT | 2HV | D13 |
| 49VU | AIR BLEED/ENG 2/MONG | 3HA2 | D12 |
| 49VU | AIR BLEED/ENG 1/CTL | 2HA1 | D11 |
| 122VU | AIR BLEED/ENG 1/MONG | 3HA1 | Z23 |
| 122VU | AIR BLEED/ENG 2/CTL | 2HA2 | Z22 |
| 122VU | AIR BLEED/X FEED VALVE/NORM | 1HV | Z20 |
C. Aircraft Maintenance Configuration
(1) Put the aircraft back to its initial configuration.
(2) Remove the access platform(s).
(3) Remove the WARNING NOTICE(S).
(1) Put the aircraft back to its initial configuration.
(2) Remove the access platform(s).
(3) Remove the WARNING NOTICE(S).
General Installation of the Duct