Installation of the Pylon Overheat Sensing-Elements
TASK 36-22-15-400-804-A
Installation of the Pylon Overheat Sensing-Elements
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Consumable Materials
C. Work Zones and Access Panels
D. Referenced Information
3. Job Set-up
Subtask 36-22-15-860-053-A
Subtask 36-22-15-420-053-A
Subtask 36-22-15-410-057-A
[Rev.10 from 2021]
2026.04.01 01:16:54 UTC
Installation of the Pylon Overheat Sensing-Elements
WARNING:
BE CAREFUL WHEN YOU DO WORK ON THE ENGINE PARTS AFTER THE ENGINE SHUTDOWN. USE APPLICABLE THERMAL GLOVES. THE ENGINE PARTS CAN STAY HOT FOR ONE HOUR AFTER SHUTDOWN AND CAN BURN YOU.
WARNING:
YOU MUST NOT TOUCH HOT PARTS WITHOUT APPLICABLE GLOVES. HOT PARTS CAN CAUSE AN INJURY.
WARNING:
PUT THE SAFETY DEVICES AND THE WARNING NOTICES IN POSITION BEFORE YOU START A TASK ON OR NEAR:
- THE FLIGHT CONTROLS
- THE FLIGHT CONTROL SURFACES
- THE LANDING GEAR AND THE RELATED DOORS
- COMPONENTS THAT MOVE.
WARNING:
BE CAREFUL WHEN YOU USE CONSUMABLE MATERIALS. OBEY THE MATERIAL MANUFACTURER'S INSTRUCTIONS AND YOUR LOCAL REGULATIONS.
1. Reason for the JobSelf explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | ACCESS PLATFORM 4M (13 FT)-ADJUSTABLE |
| No specific | 1 | GUN - SPRAY |
| No specific | 1 | NITROGEN 1.7 TO 2 BAR (25 TO 30 PSI) |
| No specific | AR | WARNING NOTICE(S) |
| No specific | Torque wrench: range to between 0.68 and 0.57 m.daN (60.18 and 50.44 lbf.in ) ![]() | |
| 98D27803000000 | 1 | LOCKING TOOL-FLAP SLAT LEVER,INT. POSITION |
| REFERENCE | DESIGNATION |
|---|---|
| (Material No.08BGB1) | Non Aqueous Cleaner-Sensing element - Xylene based - |
| (Material No.14QDC1) | Wire-Locking Dia: 0.5 mm (0.020 inch) CRES - |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 413 | UPPER FWD PYLON |
| 414 | UPPER FWD PYLON |
| 423 | UPPER FWD PYLON |
| 424 | UPPER FWD PYLON |
| 191DB | |
| FOR [106HF1] (SENSING ELEMENT-OVHT, L PYLON LOOP B) | |
| FOR [6HF1] (SENSING ELEMENT-OVHT, L PYLON LOOP A) | |
| 413BT, 414AR | |
| FOR [106HF2] (SENSING ELEMENT-OVHT, R PYLON LOOP B) | |
| FOR [6HF2] (SENSING ELEMENT-OVHT, R PYLON LOOP A) | |
| 423BT, 424AR | |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-41-00-861-002-A | Energize the Aircraft Electrical Circuits from the External Power |
| TASK 24-41-00-861-002-A-01 | Energize the Aircraft Electrical Circuits from the APU |
| TASK 24-41-00-861-002-A-02 | Energize the Aircraft Electrical Circuits from Engine 1(2) |
| TASK 24-41-00-862-002-A | De-energize the Aircraft Electrical Circuits Supplied from the External Power |
| TASK 24-41-00-862-002-A-01 | De-energize the Aircraft Electrical Circuits Supplied from the APU |
| TASK 24-41-00-862-002-A-02 | De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2) |
| TASK 27-00-00-480-002-A | Installation of the Flap/Slat Control-Lever Locking Tool (98D27803000000) |
| TASK 36-22-00-710-803-A | Operational Test of the Overheat Detection System |
| TASK 54-52-11-000-807-A | Removal of the Access Skin Panels |
| TASK 54-52-11-400-807-A | Installation of the Access Skin Panels |
Subtask 36-22-15-860-053-A
A. Aircraft Maintenance Configuration
(1) Make sure that the aircraft electrical circuits are energized (Ref. AMM TASK 24-41-00-861-002).
(2) On AIR COND panel 30VU:
Subtask 36-22-15-865-060-A (1) Make sure that the aircraft electrical circuits are energized (Ref. AMM TASK 24-41-00-861-002).
(2) On AIR COND panel 30VU:
- Make sure that the ENG 1(2) BLEED pushbutton switch is released (OFF legend on).
- Make sure that the APU BLEED pushbutton switch is released (ON legend off).
- Make sure that the WARNING NOTICE(S) is in position to tell persons not to operate the pneumatic system.
- Make sure that the ENG/MODE selector switch is in the NORM position.
- Make sure that the ENG/MASTER 1(2) control switch was in the OFF position not less than five minutes before you do this procedure.
- Make sure that a WARNING NOTICE(S) is in position to tell persons not to operate the ENG/MODE selector switch and the ENG/MASTER 1(2) control switch.
- Make sure that the ON legend of the ENG/FADEC GND PWR/1(2) pushbutton switch is off.
- Make sure that the WARNING NOTICE(S) is in position to tell persons not to energize FADEC system 1(2).
- Make sure that the 98D27803000000 LOCKING TOOL-FLAP SLAT LEVER,INT. POSITION is in position on the flap/slat control lever (Ref. AMM TASK 27-00-00-480-002).
- Make sure that a WARNING NOTICE(S) is in position on the flap/slat control lever to tell persons not to operate the flap/slat controls.
- Make sure that the WARNING NOTICE(S) is in position to tell persons not to pressurize the pneumatic system.
B. Make sure that this(these) circuit breaker(s) is(are) open, safetied and tagged:
Subtask 36-22-15-010-061-A | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C ALL | |||
| FOR FIN: 106HF1 (SENSING ELEMENTOVHT, L PYLON LOOP B) FOR FIN: 6HF1 (SENSING ELEMENTOVHT, L PYLON LOOP A) | |||
| 49VU | AIR BLEED/ENG 1/CTL | 2HA1 | D11 |
| 122VU | AIR BLEED/ENG 1/MONG | 3HA1 | Z23 |
| FOR FIN: 106HF2 (SENSING ELEMENTOVHT, R PYLON LOOP B) FOR FIN: 6HF2 (SENSING ELEMENTOVHT, R PYLON LOOP A) | |||
| 49VU | AIR BLEED/ENG 2/MONG | 3HA2 | D12 |
| 122VU | AIR BLEED/ENG 2/CTL | 2HA2 | Z22 |
C. Get Access
(1) Make sure that these access panels are removed (Ref. AMM TASK 54-52-11-000-807):
(a) FOR [6HF1] (SENSING ELEMENT-OVHT, L PYLON LOOP A), [106HF1] (SENSING ELEMENT-OVHT, L PYLON LOOP B)
413BT 414AR
(b) FOR [6HF2] (SENSING ELEMENT-OVHT, R PYLON LOOP A), [106HF2] (SENSING ELEMENT-OVHT, R PYLON LOOP B)
423BT 424AR
Subtask 36-22-15-110-057-A (1) Make sure that these access panels are removed (Ref. AMM TASK 54-52-11-000-807):
(a) FOR [6HF1] (SENSING ELEMENT-OVHT, L PYLON LOOP A), [106HF1] (SENSING ELEMENT-OVHT, L PYLON LOOP B)
413BT 414AR
(b) FOR [6HF2] (SENSING ELEMENT-OVHT, R PYLON LOOP A), [106HF2] (SENSING ELEMENT-OVHT, R PYLON LOOP B)
423BT 424AR
D. Cleaning
(1) Remove the CAP-BLANKING from each electrical connector and receptacle.
(2) Apply the Non Aqueous Cleaner-Sensing element - Xylene based - (Material No.08BGB1) with a GUN - SPRAY:
4. Procedure(1) Remove the CAP-BLANKING from each electrical connector and receptacle.
(2) Apply the Non Aqueous Cleaner-Sensing element - Xylene based - (Material No.08BGB1) with a GUN - SPRAY:
- On the end fittings of the sensing elements, of the cable assemblies and of all other connectors
- Into the receptacles of the connectors, where necessary, to clean them.
NOTE: : Do not use probes, swabs or any other instruments to examine the ends of the connectors when you clean them.
(3) Dry all parts of the sensing elements. WARNING:
DO NOT EXCEED 30PSIG (2,1KG/CM2) OF PRESSURE AT THE NOZZLE WHEN USING COMPRESSED AIR OR NITROGEN IN THIS CLEANING PROCESS. ALSO WEAR STURDY GOGGLES OR A FACE SHIELD. PARTICLES OR LIQUID DROPLETS PROPELLED BY HIGH PRESURE CAN CAUSE PERMANENT EYE INJURY.
(a) Dry all the components with a NITROGEN 1.7 TO 2 BAR (25 TO 30 PSI) at a pressure of not more than 2.1 bar (30.46 psi). Subtask 36-22-15-420-053-A
A. Installation of the Overheat Sensing Element
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Install the grommets (13) on the sensing element (8).
(3) Install the sensing element (8) with the grommets (13) on the support (9).
(4) Put the grommets (13) in the correct position in the clamps (14).
(5) Lock the clamps (14)
(6) Install the nuts (5) and (10) on the sensing elements (8).
(7) TORQUE the nuts (5) and (10) to between 0.68 and 0.57 m.daN (60.18 and 50.44 lbf.in )
.
(8) Installation of the lockwire
14QDC1 Wire-Locking Dia: 0.5 mm (0.020 inch) CRES - .
(9) Install the support (9) with the sensing element (8) in its housing on the bulkhead.
(11) Connect the electrical connectors (4) and (11).
(12) TORQUE the electrical connectors (4) and (11) to between 0.68 and 0.57 m.daN (60.18 and 50.44 lbf.in )
.
(13) Installation of the lockwire
14QDC1 Wire-Locking Dia: 0.5 mm (0.020 inch) CRES - .
Subtask 36-22-15-865-061-A (1) Make sure that the work area is clean and clear of tools and other items.
(2) Install the grommets (13) on the sensing element (8).
(3) Install the sensing element (8) with the grommets (13) on the support (9).
(4) Put the grommets (13) in the correct position in the clamps (14).
(5) Lock the clamps (14)
CAUTION:
DO NOT USE ELECTRICAL OR PNEUMATIC TOOLS TO LOOSEN OR TIGHTEN THE QUARTER-TURN FASTENER ON THE FIRE DETECTOR CLAMP. ONLY USE A MANUAL SCREWDRIVER. ELECTRICAL OR PNEUMATIC TOOLS WILL CAUSE THE FASTENER TO TURN TOO MUCH AND POSSIBLY TO BREAK.
(a) Close the clamps (14) and lock them with the quarter-turn fasteners (12). (6) Install the nuts (5) and (10) on the sensing elements (8).
(7) TORQUE the nuts (5) and (10) to between 0.68 and 0.57 m.daN (60.18 and 50.44 lbf.in )
. (8) Installation of the lockwire
WARNING:
USE PROTECTIVE GOGGLES AND GLOVES WHEN YOU REMOVE OR INSTALL LOCKWIRE. EACH TIME YOU CUT LOCKWIRE, REMOVE AND DISCARD IT IMMEDIATELY. LOOSE LOCKWIRE CAN CUT YOU OR MAKE YOU BLIND, AND/OR CAN CAUSE DAMAGE.
(a) Safety the nuts (5) and (10) with the (9) Install the support (9) with the sensing element (8) in its housing on the bulkhead.
NOTE: Make sure that there are no pieces of lockwire between the support (9) and its housing.
(10) Install the bolts (6) and the washers (7). Tighten the bolts (6). (11) Connect the electrical connectors (4) and (11).
(12) TORQUE the electrical connectors (4) and (11) to between 0.68 and 0.57 m.daN (60.18 and 50.44 lbf.in )
. (13) Installation of the lockwire
WARNING:
USE PROTECTIVE GOGGLES AND GLOVES WHEN YOU REMOVE OR INSTALL LOCKWIRE. EACH TIME YOU CUT LOCKWIRE, REMOVE AND DISCARD IT IMMEDIATELY. LOOSE LOCKWIRE CAN CUT YOU OR MAKE YOU BLIND, AND/OR CAN CAUSE DAMAGE.
(a) Safety the electrical connectors (4) and (11) with the B. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
Subtask 36-22-15-710-054-A | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C ALL | |||
| FOR FIN: 106HF1 (SENSING ELEMENTOVHT, L PYLON LOOP B) FOR FIN: 6HF1 (SENSING ELEMENTOVHT, L PYLON LOOP A) | |||
| 49VU | AIR BLEED/ENG 1/CTL | 2HA1 | D11 |
| 122VU | AIR BLEED/ENG 1/MONG | 3HA1 | Z23 |
| FOR FIN: 106HF2 (SENSING ELEMENTOVHT, R PYLON LOOP B) FOR FIN: 6HF2 (SENSING ELEMENTOVHT, R PYLON LOOP A) | |||
| 49VU | AIR BLEED/ENG 2/MONG | 3HA2 | D12 |
| 122VU | AIR BLEED/ENG 2/CTL | 2HA2 | Z22 |
C. Operational Test
(1) Do the operational test of the overheat detection system (Ref. AMM TASK 36-22-00-710-803).
5. Close-up(1) Do the operational test of the overheat detection system (Ref. AMM TASK 36-22-00-710-803).
Subtask 36-22-15-410-057-A
A. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Install these access panels (Ref. AMM TASK 54-52-11-400-807):
(a) FOR [6HF1] (SENSING ELEMENT-OVHT, L PYLON LOOP A), [106HF1] (SENSING ELEMENT-OVHT, L PYLON LOOP B)
413BT 414AR
(b) FOR [6HF2] (SENSING ELEMENT-OVHT, R PYLON LOOP A), [106HF2] (SENSING ELEMENT-OVHT, R PYLON LOOP B)
423BT 424AR
(3) Remove the WARNING NOTICE(S).
(4) Remove the access platform(s).
Subtask 36-22-15-862-053-A (1) Make sure that the work area is clean and clear of tools and other items.
(2) Install these access panels (Ref. AMM TASK 54-52-11-400-807):
(a) FOR [6HF1] (SENSING ELEMENT-OVHT, L PYLON LOOP A), [106HF1] (SENSING ELEMENT-OVHT, L PYLON LOOP B)
413BT 414AR
(b) FOR [6HF2] (SENSING ELEMENT-OVHT, R PYLON LOOP A), [106HF2] (SENSING ELEMENT-OVHT, R PYLON LOOP B)
423BT 424AR
(3) Remove the WARNING NOTICE(S).
(4) Remove the access platform(s).
Pylon Overheat Sensing-Elements