Installation of the Pylon Overheat Sensing-Element
TASK 36-22-15-400-001-A
Installation of the Pylon Overheat Sensing-Element
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Consumable Materials
C. Work Zones and Access Panels
D. Referenced Information
3. Job Set-up
Subtask 36-22-15-860-050-A ** ON A/C NOT FOR ALL
Subtask 36-22-15-420-050-A ** ON A/C NOT FOR ALL
Subtask 36-22-15-410-059-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.01 01:16:47 UTC
Installation of the Pylon Overheat Sensing-Element
WARNING:
BE CAREFUL WHEN YOU USE CONSUMABLE MATERIALS. OBEY THE MATERIAL MANUFACTURER'S INSTRUCTIONS AND YOUR LOCAL REGULATIONS.
1. Reason for the JobSelf explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | ACCESS PLATFORM 5M (16 FT)- ADJUSTABLE |
| No specific | AR | CAP - BLANKING |
| No specific | AR | GUN - SPRAY |
| No specific | AR | NITROGEN 1.7 TO 2 BAR (25 TO 30 PSI) |
| No specific | AR | WARNING NOTICE(S) |
| FOR [1HF1] (SNSG ELEM-OVHT, ENG 1 PYLON) | ||
| No specific | Torque wrench: range to between 0.69 and 0.58 m.daN (61.06 and 51.33 lbf.in ) ![]() | |
| FOR [1HF2] (SNSG ELEM-OVHT, ENG 2 PYLON) | ||
| No specific | Torque wrench: range to between 0.69 and 0.58 m.daN (61.06 and 51.33 lbf.in ) ![]() | |
| REFERENCE | DESIGNATION |
|---|---|
| (Material No.08BGB1) | Non Aqueous Cleaner-Sensing element - Xylene based - |
| FOR [1HF1] (SNSG ELEM-OVHT, ENG 1 PYLON) | |
| (Material No.14QDC1) | Wire-Locking Dia: 0.5 mm (0.020 inch) CRES - |
| FOR [1HF2] (SNSG ELEM-OVHT, ENG 2 PYLON) | |
| (Material No.14QDC1) | Wire-Locking Dia: 0.5 mm (0.020 inch) CRES - |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 413 | UPPER FWD PYLON |
| 424 | UPPER FWD PYLON |
| FOR [1HF1] (SNSG ELEM-OVHT, ENG 1 PYLON) | |
| 413CL | |
| 413CR, 413DT, 471AL, 471AR | |
| 413DL, 414CR, 414FR | |
| FOR [1HF2] (SNSG ELEM-OVHT, ENG 2 PYLON) | |
| 423CL | |
| 423CR, 423DT, 481AL, 481AR | |
| 423DL, 423FL, 424CR | |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-41-00-861-002-A | Energize the Aircraft Electrical Circuits from the External Power |
| TASK 24-41-00-861-002-A-01 | Energize the Aircraft Electrical Circuits from the APU |
| TASK 24-41-00-861-002-A-02 | Energize the Aircraft Electrical Circuits from Engine 1(2) |
| TASK 24-41-00-862-002-A | De-energize the Aircraft Electrical Circuits Supplied from the External Power |
| TASK 24-41-00-862-002-A-01 | De-energize the Aircraft Electrical Circuits Supplied from the APU |
| TASK 24-41-00-862-002-A-02 | De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2) |
| TASK 24-42-00-861-001-A | Energize the Ground Service Network from the External Power |
| TASK 36-22-00-710-001-A | Operational Test of the Overheat Detection System |
| FOR [1HF1] (SNSG ELEM-OVHT, ENG 1 PYLON) | |
| TASK 54-52-11-000-002-A | Removal of the Access Panels |
| TASK 54-52-11-000-002-B | Removal of the Access Panels |
| TASK 54-52-11-400-002-A | Installation of the Access Panels |
| TASK 54-52-11-400-002-B | Installation of the Access Panels |
| TASK 54-53-11-000-002-A | Removal of the Pylon-to-Wing Access Panels |
| TASK 54-53-11-000-002-B | Removal of the Pylon-to-Wing Access Panels |
| TASK 54-53-11-400-002-A | Installation of the Pylon-to-Wing Access Panels |
| TASK 54-53-11-400-002-B | Installation of the Pylon-to-Wing Access Panels |
| FOR [1HF2] (SNSG ELEM-OVHT, ENG 2 PYLON) | |
| TASK 54-52-11-000-002-A | Removal of the Access Panels |
| TASK 54-52-11-000-002-B | Removal of the Access Panels |
| TASK 54-52-11-400-002-A | Installation of the Access Panels |
| TASK 54-52-11-400-002-B | Installation of the Access Panels |
| TASK 54-53-11-000-002-A | Removal of the Pylon-to-Wing Access Panels |
| TASK 54-53-11-000-002-B | Removal of the Pylon-to-Wing Access Panels |
| TASK 54-53-11-400-002-A | Installation of the Pylon-to-Wing Access Panels |
| TASK 54-53-11-400-002-B | Installation of the Pylon-to-Wing Access Panels |
Subtask 36-22-15-860-050-A ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
(1) Make sure that the aircraft electrical circuits are energized (Ref. AMM TASK 24-41-00-861-002).
(2) On ENG panel 115VU:
Subtask 36-22-15-860-050-B ** ON A/C NOT FOR ALL (1) Make sure that the aircraft electrical circuits are energized (Ref. AMM TASK 24-41-00-861-002).
(2) On ENG panel 115VU:
- Make sure that the WARNING NOTICE(S) is in position to tell persons not to start the engine.
- Make sure that the ENG 1(2) BLEED pushbutton switch is released (OFF legend on)
- Make sure that the APU BLEED pushbutton switch is released (ON legend off)
- Make sure that the WARNING NOTICE(S) is in position to tell persons not to operate the pneumatic system.
- Make sure that the WARNING NOTICE(S) is in position to tell persons not to pressurize the pneumatic system.
- Make sure that the ON legend of the ENG/FADEC GND PWR/1(2) is off.
- Make sure that the WARNING NOTICE(S) is in position to tell persons not to energize FADEC system 1(2).
A. Aircraft Maintenance Configuration
(1) Make sure that the aircraft electrical circuits are energized (Ref. AMM TASK 24-42-00-861-001).
(2) On ENG panel 115VU:
Subtask 36-22-15-865-051-A ** ON A/C NOT FOR ALL (1) Make sure that the aircraft electrical circuits are energized (Ref. AMM TASK 24-42-00-861-001).
(2) On ENG panel 115VU:
- Make sure that the WARNING NOTICE(S) is in position to tell persons not to start the engine.
- Make sure that the ENG 1(2) BLEED pushbutton switch is released (OFF legend on)
- Make sure that the APU BLEED pushbutton switch is released (ON legend off)
- Make sure that the WARNING NOTICE(S) is in position to tell persons not to operate the pneumatic system.
- Make sure that the WARNING NOTICE(S) is in position to tell persons not to pressurize the pneumatic system.
- Make sure that the ON legend of the ENG/FADEC GND PWR/1(2) is off.
- Make sure that the WARNING NOTICE(S) is in position to tell persons not to energize the FADEC system 1(2).
B. Make sure that this(these) circuit breaker(s) is(are) open, safetied and tagged:
Subtask 36-22-15-010-065-A ** ON A/C NOT FOR ALL | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| FOR FIN: 1HF1 (SNSG ELEMOVHT, ENG 1 PYLON) | |||
| 49VU | AIR BLEED/ENG 1/CTL | 3HA1 | D12 |
| 49VU | AIR BLEED/ENG 1/MONG | 2HA1 | D11 |
| FOR FIN: 1HF2 (SNSG ELEMOVHT, ENG 2 PYLON) | |||
| 122VU | AIR BLEED/ENG 2/CTL | 3HA2 | Z23 |
| 122VU | AIR BLEED/ENG 2/MONG | 2HA2 | Z22 |
C. Make sure that the applicable access panels are removed:
(1) FOR [1HF1] (SNSG ELEM-OVHT, ENG 1 PYLON)
(2) FOR [1HF2] (SNSG ELEM-OVHT, ENG 2 PYLON)
Subtask 36-22-15-010-065-C ** ON A/C NOT FOR ALL (1) FOR [1HF1] (SNSG ELEM-OVHT, ENG 1 PYLON)
(2) FOR [1HF2] (SNSG ELEM-OVHT, ENG 2 PYLON)
C. Make sure that the applicable access panels are removed:
(1) FOR [1HF1] (SNSG ELEM-OVHT, ENG 1 PYLON)
Subtask 36-22-15-010-065-E ** ON A/C NOT FOR ALL (1) FOR [1HF1] (SNSG ELEM-OVHT, ENG 1 PYLON)
- 413CL 413CR and 413DT (Ref. AMM TASK 54-52-11-000-002)
- 471AR and 471AL (Ref. AMM TASK 54-53-11-000-002).
C. Make sure that the applicable access panels are removed:
(1) FOR [1HF1] (SNSG ELEM-OVHT, ENG 1 PYLON)
Subtask 36-22-15-110-051-A ** ON A/C NOT FOR ALL (1) FOR [1HF1] (SNSG ELEM-OVHT, ENG 1 PYLON)
- 413CL 413CR and 413DT (Ref. AMM TASK 54-52-11-000-002)
- 471AR and 471AL (Ref. AMM TASK 54-53-11-000-002).
D. Cleaning
(1) Remove the blanking caps from the disconnected electrical connectors.
(2) Apply the Non Aqueous Cleaner-Sensing element - Xylene based - (Material No.08BGB1) with a GUN - SPRAY:
(4) Dry the components.
(5) Install the CAP - BLANKING on the disconnected electrical connectors.
4. Procedure(1) Remove the blanking caps from the disconnected electrical connectors.
(2) Apply the Non Aqueous Cleaner-Sensing element - Xylene based - (Material No.08BGB1) with a GUN - SPRAY:
- On the end fittings of the sensing elements of the cable assemblies and of all other connectors
- Into the receptacles of the connectors, where necessary to clean them.
NOTE: Do not use probes, swabs or any other instruments to examine the ends of the connectors when you clean them.
(3) Rinse all parts of the sensing elements. (4) Dry the components.
WARNING:
DO NOT EXCEED 30PSIG (2,1KG/CM2) OF PRESSURE AT THE NOZZLE WHEN USING COMPRESSED AIR OR NITROGEN IN THIS CLEANING PROCESS. ALSO WEAR STURDY GOGGLES OR A FACE SHIELD. PARTICLES OR LIQUID DROPLETS PROPELLED BY HIGH PRESURE CAN CAUSE PERMANENT EYE INJURY.
(a) Dry all the components with a NITROGEN 1.7 TO 2 BAR (25 TO 30 PSI) at a pressure of not more than 30 psi (2.1 bar). (5) Install the CAP - BLANKING on the disconnected electrical connectors.
Subtask 36-22-15-420-050-A ** ON A/C NOT FOR ALL
A. Installation of the Pylon Overheat Sensing-Element
(b) Install the four grommets (16) on the sensing element (12).
(c) Install the sensing element (12) with the grommets (16) on the support (11).
1 Make sure that the four clamps (14) are open.
(d) Put the four grommets (16) in the correct position in the clamps (14).
(e) Lock the clamps (14).
(f) Install the nuts (3) and (7) on the sensing element (12) and tighten the nuts.
1 Safety the nuts (3) and (7) with the14QDC1 Wire-Locking Dia: 0.5 mm (0.020 inch) CRES - .
(g) Install the support (11) with the sensing element (12) in its housing on the bulkhead (13).
(h) Install the washers (1), (6) and (10) and screws (2), (5) and (9).
1 Tighten the three screws (2), (5) and (9).
(i) Install the electrical connectors (4) and (8) on the sensing element (12).
1 TORQUE the electrical connectors (4) and (8) to between 0.69 and 0.58 m.daN (61.06 and 51.33 lbf.in )
.
2 Safety the electrical connectors (4) and (8) with the14QDC1 Wire-Locking Dia: 0.5 mm (0.020 inch) CRES - .
(2) FOR [1HF2] (SNSG ELEM-OVHT, ENG 2 PYLON)
(a) Remove the CAP-BLANKING from each electrical connector and receptacle.
(b) Install the four grommets (16) on the sensing element (17).
(c) Install the sensing element (17) with the grommets (16) on the support (11).
1 Make sure that the four clamps (14) are open.
(d) Put the four grommets (16) in the correct position in the clamps (14).
(e) Lock the clamps (14).
(f) Install the nuts (3) and (7) on the sensing element (17) and tighten the nuts.
1 Safety the nuts (3) and (7) with the14QDC1 Wire-Locking Dia: 0.5 mm (0.020 inch) CRES - .
(g) Install the support (11) with the sensing element (17) in its housing on the bulkhead (13).
(h) Install the washers (1), (6) and (10) and screws (2), (5) and (9).
1 Tighten the three screws (2), (5) and (9).
(i) Install the electrical connectors (4) and (8) on the sensing element (17).
1 TORQUE the electrical connectors (4) and (8) to between 0.69 and 0.58 m.daN (61.06 and 51.33 lbf.in )
.
2 Safety the electrical connectors (4) and (8) with the14QDC1 Wire-Locking Dia: 0.5 mm (0.020 inch) CRES - .
Subtask 36-22-15-865-052-A ** ON A/C NOT FOR ALL WARNING:
USE PROTECTIVE GOGGLES AND GLOVES WHEN YOU REMOVE OR INSTALL LOCKWIRE. EACH TIME YOU CUT LOCKWIRE, REMOVE AND DISCARD IT IMMEDIATELY. LOOSE LOCKWIRE CAN CUT YOU OR MAKE YOU BLIND, AND/OR CAN CAUSE DAMAGE.
(1) FOR [1HF1] (SNSG ELEM-OVHT, ENG 1 PYLON)NOTE: It is necessary to change the routing of the preformed sensing element before its installation for FIN 1HF1.
(a) Remove the CAP-BLANKING from each electrical connector and receptacle.(b) Install the four grommets (16) on the sensing element (12).
(c) Install the sensing element (12) with the grommets (16) on the support (11).
1 Make sure that the four clamps (14) are open.
(d) Put the four grommets (16) in the correct position in the clamps (14).
(e) Lock the clamps (14).
CAUTION:
DO NOT USE ELECTRICAL OR PNEUMATIC TOOLS TO LOOSEN OR TIGHTEN THE QUARTER-TURN FASTENER ON THE FIRE DETECTOR CLAMP. ONLY USE A MANUAL SCREWDRIVER. ELECTRICAL OR PNEUMATIC TOOLS WILL CAUSE THE FASTENER TO TURN TOO MUCH AND POSSIBLY TO BREAK.
1 Close the clamps (14) and lock them with the quarter-turn fasteners (15). (f) Install the nuts (3) and (7) on the sensing element (12) and tighten the nuts.
1 Safety the nuts (3) and (7) with the
(g) Install the support (11) with the sensing element (12) in its housing on the bulkhead (13).
(h) Install the washers (1), (6) and (10) and screws (2), (5) and (9).
1 Tighten the three screws (2), (5) and (9).
(i) Install the electrical connectors (4) and (8) on the sensing element (12).
1 TORQUE the electrical connectors (4) and (8) to between 0.69 and 0.58 m.daN (61.06 and 51.33 lbf.in )
. 2 Safety the electrical connectors (4) and (8) with the
(2) FOR [1HF2] (SNSG ELEM-OVHT, ENG 2 PYLON)
(a) Remove the CAP-BLANKING from each electrical connector and receptacle.
(b) Install the four grommets (16) on the sensing element (17).
(c) Install the sensing element (17) with the grommets (16) on the support (11).
1 Make sure that the four clamps (14) are open.
(d) Put the four grommets (16) in the correct position in the clamps (14).
(e) Lock the clamps (14).
CAUTION:
DO NOT USE ELECTRICAL OR PNEUMATIC TOOLS TO LOOSEN OR TIGHTEN THE QUARTER-TURN FASTENER ON THE FIRE DETECTOR CLAMP. ONLY USE A MANUAL SCREWDRIVER. ELECTRICAL OR PNEUMATIC TOOLS WILL CAUSE THE FASTENER TO TURN TOO MUCH AND POSSIBLY TO BREAK.
1 Close the clamps (14) and lock them with the quarter-turn fasteners (15). (f) Install the nuts (3) and (7) on the sensing element (17) and tighten the nuts.
1 Safety the nuts (3) and (7) with the
(g) Install the support (11) with the sensing element (17) in its housing on the bulkhead (13).
(h) Install the washers (1), (6) and (10) and screws (2), (5) and (9).
1 Tighten the three screws (2), (5) and (9).
(i) Install the electrical connectors (4) and (8) on the sensing element (17).
1 TORQUE the electrical connectors (4) and (8) to between 0.69 and 0.58 m.daN (61.06 and 51.33 lbf.in )
. 2 Safety the electrical connectors (4) and (8) with the
B. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
Subtask 36-22-15-710-050-A ** ON A/C NOT FOR ALL 5. Close-up| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| FOR FIN: 1HF1 (SNSG ELEMOVHT, ENG 1 PYLON) | |||
| 49VU | AIR BLEED/ENG 1/CTL | 3HA1 | D12 |
| 49VU | AIR BLEED/ENG 1/MONG | 2HA1 | D11 |
| FOR FIN: 1HF2 (SNSG ELEMOVHT, ENG 2 PYLON) | |||
| 122VU | AIR BLEED/ENG 2/CTL | 3HA2 | Z23 |
| 122VU | AIR BLEED/ENG 2/MONG | 2HA2 | Z22 |
Subtask 36-22-15-410-059-A ** ON A/C NOT FOR ALL
A. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Install the applicable access panels that follow:
(a) FOR [1HF1] (SNSG ELEM-OVHT, ENG 1 PYLON)
(b) FOR [1HF2] (SNSG ELEM-OVHT, ENG 2 PYLON)
(3) Remove the WARNING NOTICE(S).
(4) Remove the access platform(s).
Subtask 36-22-15-410-059-C ** ON A/C NOT FOR ALL (1) Make sure that the work area is clean and clear of tools and other items.
(2) Install the applicable access panels that follow:
(a) FOR [1HF1] (SNSG ELEM-OVHT, ENG 1 PYLON)
(b) FOR [1HF2] (SNSG ELEM-OVHT, ENG 2 PYLON)
(3) Remove the WARNING NOTICE(S).
(4) Remove the access platform(s).
A. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Install the applicable access panels that follow:
(a) FOR [1HF1] (SNSG ELEM-OVHT, ENG 1 PYLON)
(4) Remove the access platform(s).
Subtask 36-22-15-410-059-E ** ON A/C NOT FOR ALL (1) Make sure that the work area is clean and clear of tools and other items.
(2) Install the applicable access panels that follow:
(a) FOR [1HF1] (SNSG ELEM-OVHT, ENG 1 PYLON)
- 413CL 413CR and 413DT (Ref. AMM TASK 54-52-11-400-002)
- 471AR and 471AL (Ref. AMM TASK 54-53-11-400-002).
- 423CL 423CR and 423DT (Ref. AMM TASK 54-52-11-400-002)
- 481AR and 481AL (Ref. AMM TASK 54-53-11-400-002).
(4) Remove the access platform(s).
A. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Install the applicable access panels that follow:
(a) FOR [1HF1] (SNSG ELEM-OVHT, ENG 1 PYLON)
(4) Remove the access platform(s).
Subtask 36-22-15-862-050-A ** ON A/C NOT FOR ALL (1) Make sure that the work area is clean and clear of tools and other items.
(2) Install the applicable access panels that follow:
(a) FOR [1HF1] (SNSG ELEM-OVHT, ENG 1 PYLON)
- 413CL 413CR and 413DT (Ref. AMM TASK 54-52-11-400-002)
- 471AR and 471AL (Ref. AMM TASK 54-53-11-400-002).
- 423CL 423CR and 423DT (Ref. AMM TASK 54-52-11-400-002)
- 481AR and 481AL (Ref. AMM TASK 54-53-11-400-002).
(4) Remove the access platform(s).
Pylon Overheat Sensing-Element