Detailed Inspection of the Pylon Overheat Sensing-Element
TASK 36-22-15-200-002-A
Detailed Inspection of the Pylon Overheat Sensing-Element
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 36-22-15-941-052-A ** ON A/C NOT FOR ALL
Subtask 36-22-15-210-051-A ** ON A/C NOT FOR ALL
Subtask 36-22-15-410-052-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.01 01:16:57 UTC
Detailed Inspection of the Pylon Overheat Sensing-Element
WARNING:
PUT THE SAFETY DEVICES AND THE WARNING NOTICES IN POSITION BEFORE YOU START A TASK ON OR NEAR:
- THE FLIGHT CONTROLS
- THE FLIGHT CONTROL SURFACES
- THE LANDING GEAR AND THE RELATED DOORS
- COMPONENTS THAT MOVE.
WARNING:
BEFORE YOU START WORK, YOU MUST PUT ON A SAFETY HARNESS AND ATTACH IT TO THE ACCESS PLATFORM. WITHOUT A SAFETY HARNESS, YOU CAN FALL. THIS CAN KILL YOU OR CAUSE YOU INJURY.
WARNING:
DO NOT TOUCH THE COMPONENT UNTIL IT IS SUFFICIENTLY
COOL TO PREVENT BURNS.
1. Reason for the JobSelf explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | ACCESS PLATFORM 5M (16 FT)- ADJUSTABLE |
| No specific | AR | WARNING NOTICE(S) |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| FOR [1HF1] (SNSG ELEM-OVHT, ENG 1 PYLON) | |
| 413DT, 471AL, 471AR | |
| 413CL, 413DL, 414CR, 414FR | |
| FOR [1HF2] (SNSG ELEM-OVHT, ENG 2 PYLON) | |
| 423DT, 481AL, 481AR | |
| 423CL, 423DL, 423FL, 424CR | |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 20-28-00-912-802-A | Electrical Bonding - General Maintenance Procedure |
| FOR [1HF1] (SNSG ELEM-OVHT, ENG 1 PYLON) | |
| TASK 54-53-11-000-002-B | Removal of the Pylon-to-Wing Access Panels |
| TASK 54-53-11-400-002-B | Installation of the Pylon-to-Wing Access Panels |
| FOR [1HF2] (SNSG ELEM-OVHT, ENG 2 PYLON) | |
| TASK 54-53-11-000-002-B | Removal of the Pylon-to-Wing Access Panels |
| TASK 54-53-11-400-002-B | Installation of the Pylon-to-Wing Access Panels |
Subtask 36-22-15-941-052-A ** ON A/C NOT FOR ALL
A. Safety Precautions
(1) Make sure that the engine 1(2) shutdown occurred not less than 5 minutes before you do this procedure.
(2) Put a WARNING NOTICE(S) in position to tell persons not to energize the aircraft electrical circuits.
(3) On the HP ground connector:
Subtask 36-22-15-010-053-A ** ON A/C NOT FOR ALL (1) Make sure that the engine 1(2) shutdown occurred not less than 5 minutes before you do this procedure.
(2) Put a WARNING NOTICE(S) in position to tell persons not to energize the aircraft electrical circuits.
(3) On the HP ground connector:
- Put a WARNING NOTICE(S) in position to tell persons not to operate the pneumatic system.
B. Get Access
(1) Put the ACCESS PLATFORM 5M (16 FT)- ADJUSTABLE in position at the pylon access panels.
(2) Remove these access panels:
(a) FOR [1HF1] (SNSG ELEM-OVHT, ENG 1 PYLON)
413CL 414CR 413DL 414FR
(b) FOR [1HF2] (SNSG ELEM-OVHT, ENG 2 PYLON)
423CL 424CR 423DL 423FL.
Subtask 36-22-15-010-053-B ** ON A/C NOT FOR ALL (1) Put the ACCESS PLATFORM 5M (16 FT)- ADJUSTABLE in position at the pylon access panels.
(2) Remove these access panels:
(a) FOR [1HF1] (SNSG ELEM-OVHT, ENG 1 PYLON)
413CL 414CR 413DL 414FR
(b) FOR [1HF2] (SNSG ELEM-OVHT, ENG 2 PYLON)
423CL 424CR 423DL 423FL.
B. Get Access
(1) Put the ACCESS PLATFORM 5M (16 FT)- ADJUSTABLE in position at the pylon access panels.
(2) Remove these access panels:
(a) FOR [1HF1] (SNSG ELEM-OVHT, ENG 1 PYLON)
471AR 413DT
(b) FOR [1HF2] (SNSG ELEM-OVHT, ENG 2 PYLON)
481AL 423DT
4. Procedure(1) Put the ACCESS PLATFORM 5M (16 FT)- ADJUSTABLE in position at the pylon access panels.
(2) Remove these access panels:
(a) FOR [1HF1] (SNSG ELEM-OVHT, ENG 1 PYLON)
471AR 413DT
(b) FOR [1HF2] (SNSG ELEM-OVHT, ENG 2 PYLON)
481AL 423DT
Subtask 36-22-15-210-051-A ** ON A/C NOT FOR ALL
A. Inspection of the Pylon Overheat Sensing-Elements
(1) Make sure that the clearance between the sensing elements and the duct is a minimum of 12.7 MM (0.50 IN.) 12.7 mm (0.50 in.), measured along the full length of the sensing element.
(2) Do an inspection of the sensing elements to make sure that they are installed on the outer side of the insulation.
(3) Make sure that the clearance between the sensing elements and the duct insulation is the same as at the mounting brackets.
(4) Make sure that the sensing elements are installed in the permitted tolerances.
(5) Make sure that each clamp has a silicon rubber grommet.
(6) Make sure that each mounting bracket, installed on the duct, has a spacer.
(7) Make sure that the sensing elements are installed correctly.
(8) Make sure that each mounting clamp is in the correct condition and has no corrosion.
(9) Make sure that the bonding straps are correctly attached (Ref. AMM TASK 20-28-00-912-802).
(10) Make sure that the lockwires are correctly installed on the connections of the sensing elements.
(11) Make sure that the duct insulation is in the correct condition and correctly installed.
(12) Make sure that the sensing elements have no cracks, nicks, sharp edges, bonds chafing or corrosion.
5. Close-up(1) Make sure that the clearance between the sensing elements and the duct is a minimum of 12.7 MM (0.50 IN.) 12.7 mm (0.50 in.), measured along the full length of the sensing element.
(2) Do an inspection of the sensing elements to make sure that they are installed on the outer side of the insulation.
(3) Make sure that the clearance between the sensing elements and the duct insulation is the same as at the mounting brackets.
(4) Make sure that the sensing elements are installed in the permitted tolerances.
(5) Make sure that each clamp has a silicon rubber grommet.
(6) Make sure that each mounting bracket, installed on the duct, has a spacer.
(7) Make sure that the sensing elements are installed correctly.
(8) Make sure that each mounting clamp is in the correct condition and has no corrosion.
(9) Make sure that the bonding straps are correctly attached (Ref. AMM TASK 20-28-00-912-802).
(10) Make sure that the lockwires are correctly installed on the connections of the sensing elements.
(11) Make sure that the duct insulation is in the correct condition and correctly installed.
(12) Make sure that the sensing elements have no cracks, nicks, sharp edges, bonds chafing or corrosion.
Subtask 36-22-15-410-052-A ** ON A/C NOT FOR ALL
A. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Install these access panels:
(a) FOR [1HF1] (SNSG ELEM-OVHT, ENG 1 PYLON)
413CL 414CR 413DL 414FR
(b) FOR [1HF2] (SNSG ELEM-OVHT, ENG 2 PYLON)
423CL 424CR 423DL 423FL.
(3) Remove the WARNING NOTICE(S).
(4) Remove the access platform(s).
Subtask 36-22-15-410-052-B ** ON A/C NOT FOR ALL (1) Make sure that the work area is clean and clear of tools and other items.
(2) Install these access panels:
(a) FOR [1HF1] (SNSG ELEM-OVHT, ENG 1 PYLON)
413CL 414CR 413DL 414FR
(b) FOR [1HF2] (SNSG ELEM-OVHT, ENG 2 PYLON)
423CL 424CR 423DL 423FL.
(3) Remove the WARNING NOTICE(S).
(4) Remove the access platform(s).
A. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Install these access panels:
(a) FOR [1HF1] (SNSG ELEM-OVHT, ENG 1 PYLON)
471AR 413DT
(b) FOR [1HF2] (SNSG ELEM-OVHT, ENG 2 PYLON)
481AL 423DT
(3) Remove the WARNING NOTICE(S).
(4) Remove the access platform(s).
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Install these access panels:
(a) FOR [1HF1] (SNSG ELEM-OVHT, ENG 1 PYLON)
471AR 413DT
(b) FOR [1HF2] (SNSG ELEM-OVHT, ENG 2 PYLON)
481AL 423DT
(3) Remove the WARNING NOTICE(S).
(4) Remove the access platform(s).
Permitted Tolerances of the Sensing Elements